Sandwich microgravimetric immunoassay: sensitive and specific detection of low molecular weight analytes using piezoelectric quartz crystal

被引:9
作者
Saha, S [1 ]
Raje, M [1 ]
Suri, CR [1 ]
机构
[1] Inst Microbial Technol, Chandigarh 160036, India
关键词
insulin; multi-channel; quartz crystal microbalance;
D O I
10.1023/A:1015238201367
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A multi-channel sandwich microgravimetric immunoassay (sMIA), using the quartz crystal microbalance (QCM) principle, has been developed to quantify low molecular weight substances in standard solutions. An antigen is sandwiched between two antigen-specific antibodies: the first antibody is coated on the quartz crystal surface and the second antibody is used for the detection of analyte. The concentration of low molecular weight antigen (insulin was used in this study, M(r)similar to6000 Da) was correlated with the shift of resonant frequency of QCM system before and after second antibody binding to insulin. The developed assay is highly specific showing low cross-reactivity, and is sensitive to approx. 1 ng insulin ml(-1) with a linear response for insulin from 10 mug ml(-1) to 10 ng ml(-1) in standard solutions. The technique may also be applied for the detection of other small biomolecules.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 17 条
[1]   Determination of organophosphorus and carbamate pesticides using a piezoelectric biosensor [J].
Abad, JM ;
Pariente, F ;
Hernández, L ;
Abruña, HD ;
Lorenzo, E .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2848-2855
[2]   Electrochemical and quartz crystal microbalance detection of the cholera toxin employing horseradish peroxidase and GM1-functionalized liposomes [J].
Alfonta, L ;
Willner, I ;
Throckmorton, DJ ;
Singh, AK .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5287-5295
[3]   Immunodetection by quartz crystal microbalance -: A new approach for direct detection of rabbit IgG and peroxidase [J].
Bizet, K ;
Gabrielli, C ;
Perrot, H .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) :139-149
[4]  
KABAT EA, 1976, STRUCTURAL CONCEPTS, P24
[5]  
KANAZAWA KK, 1985, ANAL CHIM ACTA, V175, P99
[6]   An on-line quantitative immunoassay system based on a quartz crystal microbalance [J].
Lin, SM ;
Lu, CC ;
Chien, HF ;
Hsu, SM .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 239 (1-2) :121-124
[7]   A PIEZOELECTRIC QUARTZ-CRYSTAL BIOSENSOR AS A DIRECT AFFINITY SENSOR [J].
MINUNNI, M ;
SKLADAL, P ;
MASCINI, M .
ANALYTICAL LETTERS, 1994, 27 (08) :1475-1487
[8]  
MURAMATSU H, 1989, ANAL LETT, V22, P2155
[9]   PIEZOELECTRIC CRYSTAL BIOSENSORS [J].
NGEHNGWAINBI, J ;
SULEIMAN, AA ;
GUILBAULT, GG .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (01) :13-26
[10]   MICROGRAVIMETRIC IMMUNOASSAY WITH PIEZOELECTRIC-CRYSTALS [J].
ROEDERER, JE ;
BASTIAANS, GJ .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2333-2336