Biological evaluation of Fe3O4-poly(L-lactide)-poly(ethylene glycol)-poly(L-lactide) magnetic microspheres prepared in supercritical CO2

被引:15
作者
Chen, Ai-Zheng [1 ,2 ]
Lin, Xiao-Fen [1 ]
Wang, Shi-Bin [1 ,2 ]
Li, Li [1 ]
Liu, Yuan-Gang [1 ,2 ]
Ye, Li [1 ]
Wang, Guang-Ya [1 ]
机构
[1] Huaqiao Univ, Coll Chem Engn, Xiamen 361021, Peoples R China
[2] Huaqiao Univ, Inst Biomat & Tissue Engn, Xiamen 361021, Peoples R China
基金
中国国家自然科学基金;
关键词
Biocompatibility; Fe3O4; PLLA-PEG-PLLA; Magnetic microspheres; Supercritical CO2; IRON-OXIDE NANOPARTICLES; IN-VITRO; SUPERPARAMAGNETIC NANOPARTICLES; CELLULAR UPTAKE; DNA-DAMAGE; CELLS; VIVO; MACROPHAGES; RESONANCE; PARTICLES;
D O I
10.1016/j.toxlet.2012.05.009
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The biocompatibility of Fe3O4-poly(L-lactide)-poly(ethylene glycol)-poly(L-lactide) magnetic microspheres (Fe3O4-PLLA-PEG-PLLA MMPs) prepared in a process of suspension-enhanced dispersion by supercritical CO2 (SpEDS) was evaluated at various levels: cellular, molecular, and integrated. At the cellular level, the investigations of cytotoxicity and intracellular reactive oxygen species (ROS) generation indicate that the polymer-coated MMPs (2.0 mg/mL) had a higher toxicity than uncoated Fe3O4 nanoparticles. which led to about 20% loss of cell viability and an increase (0.2 fold) in ROS generation; the differences were not statistically significant (p > 0.05). However, an opposite phenomenon was observed in tests of hemolysis, which showed that the MMPs displayed the weakest hemolytic activity, namely only about 6% at the highest concentration (20 mg/mL). This phenomenon reveals that polymer-coated MMPs created less toxicity in red blood cells than uncoated Fe3O4 nanoparticles. At the molecular level, the MMPs were shown to be less genotoxic than Fe3O4 nanoparticles by measuring the micronucleus (MN) frequency in CHO-K1 cells. Furthermore, the mRNA expression of pro-inflammatory cytokines demonstrates that polymer-coated MMPs elicited a less intense secretion of pro-inflammatory cytokines than uncoated Fe3O4 nanoparticles. Acute toxicity tests of MMPs show quite a low toxicity, with an LD50 > 1575.00 mg/kg. The evidence of low toxicity presented in the results indicates that the Fe3O4-PLLA-PEG-PLLA MMPs from the SpEDS process have great potential for use in biomedical applications. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 40 条
[1]   DNA damage response to different surface chemistry of silver nanoparticles in mammalian cells [J].
Ahamed, Maqusood ;
Karns, Michael ;
Goodson, Michael ;
Rowe, John ;
Hussain, Saber M. ;
Schlager, John J. ;
Hong, Yiling .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2008, 233 (03) :404-410
[2]   PEO coated magnetic nanoparticles for biomedical application [J].
Aqil, A. ;
Vasseur, S. ;
Duguet, E. ;
Passirani, C. ;
Benoit, J. P. ;
Roch, A. ;
Muller, R. ;
Jerome, R. ;
Jerome, C. .
EUROPEAN POLYMER JOURNAL, 2008, 44 (10) :3191-3199
[3]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[4]   Dextran and albumin derivatised iron oxide nanoparticles: influence on fibroblasts in vitro [J].
Berry, CC ;
Wells, S ;
Charles, S ;
Curtis, ASG .
BIOMATERIALS, 2003, 24 (25) :4551-4557
[5]   The toxicological impact of nanoparticles [J].
Brayner, Roberta .
NANO TODAY, 2008, 3 (1-2) :48-55
[6]  
CHOU LS, 1995, J CELL SCI, V108, P1563
[7]   APPLICATION OF INVIVO NMR-SPECTROSCOPY TO CANCER [J].
EVANOCHKO, WT ;
NG, TC ;
GLICKSON, JD .
MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (04) :508-534
[8]   Cytokinesis-block micronucleus cytome assay [J].
Fenech, Michael .
NATURE PROTOCOLS, 2007, 2 (05) :1084-1104
[9]   Nanotoxicity:: the growing need for in vivo study [J].
Fischer, Hans C. ;
Chan, Warren C. W. .
CURRENT OPINION IN BIOTECHNOLOGY, 2007, 18 (06) :565-571
[10]   Biofunctional magnetic nanoparticles for protein separation and pathogen detection [J].
Gu, HW ;
Xu, KM ;
Xu, CJ ;
Xu, B .
CHEMICAL COMMUNICATIONS, 2006, (09) :941-949