Efficacy of Sonazoid (Perflubutane) for Contrast-Enhanced Ultrasound in the Differentiation of Focal Breast Lesions: Phase 3 Multicenter Clinical Trial

被引:67
作者
Miyamoto, Yukio [1 ]
Ito, Toshikazu [2 ]
Takada, Etsuo [3 ]
Omoto, Kiyoka [4 ]
Hirai, Toshiko [5 ]
Moriyasu, Fuminori [6 ]
机构
[1] Jikei Univ Hosp, Dept Diagnost Imaging, Minato Ku, Tokyo 1058471, Japan
[2] Rinku Gen Med Ctr, Dept Surg, Izumisano, Osaka, Japan
[3] Dokkyo Med Univ Hosp, Ctr Med Ultrason, Mibu, Tochigi, Japan
[4] Jichi Med Univ, Saitama Med Ctr, Dept Lab Med, Saitama, Japan
[5] Nara Med Univ Hosp, Dept Endoscopy & Ultrasound, Kashihara, Nara, Japan
[6] Tokyo Med Univ, Dept Gastroenterol & Hepatol, Shinjuku Ku, Tokyo 1608402, Japan
关键词
breast; contrast-enhanced ultrasound; diagnosis; perflubutane; Sonazoid; DIAGNOSIS; MRI; BENIGN;
D O I
10.2214/AJR.12.10518
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare the efficacy of contrast-enhanced ultrasound (CEUS) using the ultrasound contrast agent Sonazoid (perflubutane) with unenhanced ultrasound and supplementary contrast-enhanced MRI in the differential diagnosis (benign vs malignant) of focal breast lesions. The safety of Sonazoid was also assessed in this study. SUBJECTS AND METHODS. A total of 127 patients with focal breast lesions were enrolled in this study at five centers in Japan. Three reviewers who were blinded to the patient characteristics independently assessed the ultrasound images and MR images in a randomized sequence. The accuracy, sensitivity, and specificity of CEUS, unenhanced ultrasound, and supplementary contrast-enhanced MRI for the differential diagnosis were compared using generalized estimating equation analyses. Diagnostic confidence was also assessed. RESULTS. The accuracy of CEUS was significantly higher than that of unenhanced ultrasound (87.2% vs 65.5%, respectively; p < 0.001). In addition, CEUS showed significantly higher specificity, although the improvement in sensitivity was not statistically significant. The accuracy and specificity were significantly higher with CEUS than with contrast-enhanced MRI, but the improvement in sensitivity was not statistically significant. The area under the curve in a receiver operating characteristic analysis was significantly greater with CEUS than with unenhanced ultrasound. The incidence of adverse events was 11.4% and the incidence of adverse drug reactions was 3.3%. All adverse drug reactions were mild. CONCLUSION. CEUS using Sonazoid was confirmed to be superior to unenhanced ultrasound for the differential diagnosis (benign vs malignant) of focal breast lesions in terms of diagnostic accuracy with no serious adverse reactions.
引用
收藏
页码:W400 / W407
页数:8
相关论文
共 35 条
  • [1] Diagnostic value of contrast-enhanced computed tomography for diagnosing the intraductal component of breast cancer
    Akashi-Tanaka, S
    Fukutomi, T
    Miyakawa, K
    Uchiyama, N
    Tsuda, H
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 1998, 49 (01) : 79 - 86
  • [2] Akiko H, 2012, KANZO, V53, P721
  • [3] American College of Radiology, 2008, ACR PRACT GUID PERF
  • [4] Correlation Between Contrast-Enhanced Intraoperative Ultrasound Using Sonazoid and Histologic Grade of Resected Hepatocellular Carcinoma
    Arita, Junichi
    Hasegawa, Kiyoshi
    Takahashi, Michiro
    Hata, Shojiro
    Shindoh, Junichi
    Sugawara, Yasuhiko
    Kokudo, Norihiro
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : 1314 - 1321
  • [5] New potential and applications of contrast-enhanced ultrasound of the breast: Own investigations and review of the literature
    Balleyguier, Corinne
    Opolon, Paule
    Mathieu, Marie Christine
    Athanasiou, Alexandra
    Garbay, Jean Remi
    Delaloge, Suzette
    Drornain, Clarisse
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (01) : 14 - 23
  • [6] Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries
    Berrington de González, A
    Darby, S
    [J]. LANCET, 2004, 363 (9406) : 345 - 351
  • [7] Contrast-enhanced ultrasound in the characterisation of breast masses: utility of quantitative analysis in comparison with MRI
    Caproni, Natalia
    Marchisio, Francesca
    Pecchi, Annarita
    Canossi, Barbara
    Battista, Rachele
    D'Alimonte, Piero
    Torricelli, Pietro
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (06) : 1384 - 1395
  • [8] Characterization of solid breast masses -: Use of the sonographic breast imaging reporting and data system lexicon
    Costantini, Melania
    Belli, Paolo
    Lombardi, Roberta
    Franceschini, Gianluca
    Mule, Antonino
    Bonomo, Lorenzo
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (05) : 649 - 659
  • [9] Screening for hereditary breast cancer
    Dent, Rebecca
    Warner, Ellen
    [J]. SEMINARS IN ONCOLOGY, 2007, 34 (05) : 392 - 400
  • [10] Microvascular architecture of breast lesions - Evaluation with contrast-enhanced ultrasonographic micro flow imaging
    Du, Jing
    Li, Feng-Hua
    Fang, Hua
    Xia, Jian-Guo
    Zhu, Cai-Xia
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (06) : 833 - 842