Identification of Coffee Fragrances Using Needle Trap Device-Gas Chromatograph/Mass Spectrometry (NTD-GC/MS)

被引:15
作者
Eom, In-Yong [1 ]
Jung, Min-Ji [1 ]
机构
[1] Catholic Univ Daegu, Coll Nat Sci, Dept Life Chem, Gyongsan 712702, South Korea
基金
新加坡国家研究基金会;
关键词
Sorbent tube; Microextraction; Needle trap device; Coffee fragrance; Kovat index; SOLID-PHASE MICROEXTRACTION; VOLATILE ORGANIC-COMPOUNDS; EXTRACTION; AIR;
D O I
10.5012/bkcs.2013.34.6.1703
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A fast and simple sampling and sample preparation device, (NTD) has been developed and applied to sample and analyze volatile components from ground coffee beans. Coffee fragrances and other volatile organic compounds (VOCs) were sampled by the NTD and then analyzed by gas chromatograph-mass spectrometry (GC/MS). Divinylbenzene (DVB) particles (80/100 mesh size) were the sorbent bed of the NTD. More than 150 volatile components were first identified based on the database of the mass library and then finally 30 fragrances including caffeine were further confirmed by comparing experimental retention indices (i.e. Kovat index) with literature retention indices. Total sampling time was 10 minutes and no extra solvent extraction and/or reconstitution step need. Straight n-alkanes (C6-C20) were used as retention index probes for the calculation of experimental retention indices. In addition, this report suggests that an empty needle can be an alternative platform for analyzing polymers by pyrolysis-GC/MS.
引用
收藏
页码:1703 / 1707
页数:5
相关论文
共 17 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   Stir bar sorptive extraction for trace analysis [J].
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :54-69
[3]   Simple sample transfer technique by internally expanded desorptive flow for needle trap devices [J].
Eom, In-Yong ;
Pawliszyn, Janusz .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (12) :2283-2287
[4]   Development and application of needle trap devices [J].
Eom, In-Yong ;
Tugulea, Anca-Maria ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1196 :3-9
[5]   Development of a syringe pump assisted dynamic headspace sampling technique for needle trap device [J].
Eom, In-Yong ;
Niri, Vadoud H. ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1196 (1196-1197) :10-14
[6]   Simultaneous sampling and analysis of indoor air infested with Cimex lectularius L. (Hemiptera: Cimicidae) by solid phase microextraction, thin film microextraction and needle trap device [J].
Eom, In-Yong ;
Risticevic, Sanja ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2012, 716 :2-10
[7]   Estimation of Partition Coefficients of Benzene, Toluene, Ethylbenzene, and p-Xylene by Consecutive Extraction with Solid Phase Microextraction [J].
Eom, In-Yong .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (05) :1463-1464
[8]   Development and application of a needle trap device for time-weighted average diffusive sampling [J].
Gong, Ying ;
Eom, In-Yong ;
Lou, Da-Wei ;
Hein, Dietmar ;
Pawliszyn, Janusz .
ANALYTICAL CHEMISTRY, 2008, 80 (19) :7275-7282
[9]   Sorbent trapping of volatile organic compounds from air [J].
Harper, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :129-151
[10]   A novel needle trap device with single wall carbon nanotubes sol-gel sorbent packed for sampling and analysis of volatile organohalogen compounds in air [J].
Heidari, Mahmoud ;
Bahrami, Abdolrahman ;
Ghiasvand, Ali Reza ;
Shahna, Farshid Ghorbani ;
Soltanian, Ali Reza .
TALANTA, 2012, 101 :314-321