The transtympanic promontory stimulation test in patients with auditory deprivation: correlations with electrical dynamics of cochlear implant and speech perception

被引:14
作者
Alfelasi, Mohammad [1 ,2 ,3 ]
Piron, Jean Pierre [1 ,2 ]
Mathiolon, Caroline [1 ,2 ]
Lenel, Nadjmah [1 ,2 ]
Mondain, Michel [1 ,2 ,4 ]
Uziel, Alain [1 ,2 ,4 ]
Venail, Frederic [1 ,2 ,4 ]
机构
[1] CHU Gui de Chauliac, Otol & Neurotol Dept, F-34295 Montpellier, France
[2] CHU Gui de Chauliac, Cochlear Implant Ctr, F-34295 Montpellier, France
[3] CHU Gui de Chauliac, Serv ORL, F-34295 Montpellier, France
[4] INSERM, U1051, Res Unit, Inst Neurosci Montpellier, Montpellier, France
关键词
Transtympanic promontory stimulation test; Speech perception; Cochlear implant; ACTION-POTENTIAL THRESHOLDS; C-LEVELS; NERVE-FIBERS; RANGE; CHILDREN; PERFORMANCE; USERS;
D O I
10.1007/s00405-012-2125-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Transtympanic promontory stimulation test (TPST) has been suggested to be a useful tool in predicting postoperative outcomes in patients at risk of poor auditory neuron functioning, especially after a long auditory deprivation. However, only sparse data are available on this topic. This study aimed at showing correlations between the auditory nerve dynamic range, evaluated by TPST, the electrical dynamic range of the cochlear implant and speech perception outcome. We evaluated 65 patients with postlingual hearing loss and no residual hearing, implanted with a Nucleus CI24 cochlear implant device for at least 2 years and with a minimum of 17 active electrodes. Using the TPST, we measured the threshold for auditory perception (T-level) and the maximum acceptable level of stimulation (M-level) at stimulation frequencies of 50, 100 and 200 Hz. General linear regression was performed to correlate 1/speech perception, evaluated using the PBK test 1 year after surgery, and 2/cochlear implant electrical dynamic range, with the age at time of implantation, the duration of auditory deprivation, the etiology of the deafness, the duration of cochlear implant use and auditory nerve dynamic range. Postoperative speech perception outcome correlated with etiology, duration of auditory deprivation and implant use, and TPST at 100 and 200 Hz. The dynamic range of the cochlear implant map correlated with duration of auditory deprivation, speech perception outcome at 6 months and TPST at 100 and 200 Hz. TPST test can be used to predict functional outcome after cochlear implant surgery in difficult cases.
引用
收藏
页码:1809 / 1815
页数:7
相关论文
共 33 条
  • [1] Albu S., 1997, Acta Oto-Rhino-Laryngologica Belgica, V51, P11
  • [2] Using Evoked Compound Action Potentials to Assess Activation of Electrodes and Predict C-Levels in the Tempo plus Cochlear Implant Speech Processor
    Alvarez, Isaac
    de la Torre, Angel
    Sainz, Manuel
    Roldan, Cristina
    Schoesser, Hansjoerg
    Spitzer, Philipp
    [J]. EAR AND HEARING, 2010, 31 (01) : 134 - 145
  • [3] Black Jane, 2011, Cochlear Implants Int, V12, P67, DOI 10.1179/146701010X486417
  • [4] Blamey Peter J, 2005, Trends Amplif, V9, P77, DOI 10.1177/108471380500900203
  • [5] FACTORS PREDICTING POSTOPERATIVE SENTENCE SCORES IN POSTLINGUISTICALLY DEAF ADULT COCHLEAR IMPLANT PATIENTS
    BLAMEY, PJ
    PYMAN, BC
    CLARK, GM
    DOWELL, RC
    GORDON, M
    BROWN, AM
    HOLLOW, RD
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1992, 101 (04) : 342 - 348
  • [6] Boyd Paul, 2009, Cochlear Implants Int, V10, P203, DOI 10.1179/cim.2009.10.4.203
  • [7] RELATIONS BETWEEN AUDIOMETRICAL THRESHOLDS OF POTENTIAL COCHLEAR IMPLANT PATIENTS AND THEIR PERFORMANCE IN PREOPERATIVE PSYCHO-PHYSICAL TESTS WITH ELECTRICAL-STIMULATION
    BROKX, JPL
    HOMBERGEN, G
    CONINX, F
    [J]. SCANDINAVIAN AUDIOLOGY, 1988, 17 (04): : 217 - 222
  • [8] Cosendai G, 2001, AUDIOLOGY, V40, P272
  • [9] The Effect of Instantaneous Input Dynamic Range Setting on the Speech Perception of Children with the Nucleus 24 Implant
    Davidson, Lisa S.
    Skinner, Margaret W.
    Holstad, Beth A.
    Fears, Beverly T.
    Richter, Marie K.
    Matusofsky, Margaret
    Brenner, Christine
    Holden, Timothy
    Birath, Amy
    Kettel, Jerrica L.
    Scollie, Susan
    [J]. EAR AND HEARING, 2009, 30 (03) : 340 - 349
  • [10] Optimizing dynamic range in children using the nucleus cochlear implant
    Dawson, PW
    Decker, JA
    Psarros, CE
    [J]. EAR AND HEARING, 2004, 25 (03) : 230 - 241