Electrospun metal-organic framework/polyacrylonitrile composite nanofibrous mat as a microsorbent for the extraction of tetracycline residue in human blood plasma

被引:29
作者
Arabsorkhi, Batoul [1 ]
Sereshti, Hassan [1 ]
Abbasi, Alireza [1 ]
机构
[1] Univ Tehran, Sch Chem, Coll Sci, Tehran, Iran
关键词
antibiotics; electrospun composite nanofibers; high-performance liquid chromatography; metal-organic frameworks; polyacrylonitrile; SOLID-PHASE EXTRACTION; MOLECULARLY IMPRINTED POLYMER; POLYCYCLIC AROMATIC-HYDROCARBONS; FRAMEWORK; WATER; MICROEXTRACTION; PERFORMANCE; ANTIBIOTICS; TANDEM; MILK;
D O I
10.1002/jssc.201801305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new composite nanofiber of polyacrylonitrile doped with copper benzene-1,3,5-tricarboxylate metal-organic framework was fabricated by electrospinning and used as a microsorbent in the solid-phase extraction of trace tetracycline. The chemical structure of the adsorbent was studied by X-ray diffraction, scanning electron microscopy, Fourier transform infrared spectroscopy, Brunauer-Emmett-Teller surface area analysis, and Barrett-Joyner-Halenda pore size and volume analysis techniques. The significant parameters of the method including desorption solvent kind and volume, adsorbent mass, pH, and salt percentage were investigated. At the optimized conditions, the linear range was 8-1000 mu g/L with a determination coefficient (R-2) of 0.9954. The limits of detection and quantification were 2.40 and 8.00 mu g/L, respectively. The inter-and intraday precisions were 4.7 and 3.4%, respectively. The developed extraction method was followed by high-performance liquid chromatography and applied for the determination of tetracycline in human blood plasma, and good relative recoveries (97.3-104.5%) were obtained.
引用
收藏
页码:1500 / 1508
页数:9
相关论文
共 40 条
[31]   A reversed-phase high performance liquid chromatography coupled with resonance Rayleigh scattering detection for the determination of four tetracycline antibiotics [J].
Wang, Li-Feng ;
Peng, Jing-Dong ;
Liu, Li-Min .
ANALYTICA CHIMICA ACTA, 2008, 630 (01) :101-106
[32]   Analysis of tetracyclines from milk powder by molecularly imprinted solid-phase dispersion based on a metal-organic framework followed by ultra high performance liquid chromatography with tandem mass spectrometry [J].
Wang, Shangshu ;
Zhang, Jianfeng ;
Li, Chenyu ;
Chen, Ligang .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (12) :2604-2612
[33]   Magnetic solid phase extraction based on graphene oxide/nanoscale zero-valent iron for the determination of tetracyclines in water and milk by using HPLC-MS/MS [J].
Wei, Dan ;
Wu, Shuchao ;
Zhu, Yan .
RSC ADVANCES, 2017, 7 (70) :44578-44586
[34]   Simultaneous residue monitoring of four tetracycline antibiotics in fish muscle by in-tube solid-phase microextraction coupled with high-performance liquid chromatography [J].
Wen, Yi ;
Wang, Ying ;
Feng, Yu-Qi .
TALANTA, 2006, 70 (01) :153-159
[35]   Determination of Tetracyclines in Milk by Graphene-Based Solid-Phase Extraction and High-Performance Liquid Chromatography [J].
Wu, Xia Jun ;
Wang, Geng Nan ;
Yang, Kun ;
Liu, Hui Zhi ;
Wang, Jian Ping .
ANALYTICAL LETTERS, 2017, 50 (04) :641-650
[36]   Fabrication of metal-organic framework MIL-88B films on stainless steel fibers for solid-phase microextraction of polychlorinated biphenyls [J].
Wu, Ye-Yu ;
Yang, Cheng-Xiong ;
Yan, Xiu-Ping .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1334 :1-8
[37]   Simultaneous Determination of Erythromycin, Tetracycline, and Chloramphenicol Residue in Raw Milk by Molecularly Imprinted Polymer Mixed with Solid-Phase Extraction [J].
Xie, Yunfei ;
Hu, Qi ;
Zhao, Mengyao ;
Cheng, Yuliang ;
Guo, Yahui ;
Qian, He ;
Yao, Weirong .
FOOD ANALYTICAL METHODS, 2018, 11 (02) :374-381
[38]   Determination of tetracyclines in bovine milk using laccaic acid-loaded magnetite nanocomposite for magnetic solid-phase extraction [J].
Yu, Youwei ;
Fan, Zhefeng .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (04) :484-490
[39]   Electrospun polyacrylonitrile nanocomposite fibers reinforced with Fe3O4 nanoparticles: Fabrication and property analysis [J].
Zhang, Di ;
Karki, Amar B. ;
Rutman, Dan ;
Young, David R. ;
Wang, Andrew ;
Cocke, David ;
Ho, Thomas H. ;
Guo, Zhanhu .
POLYMER, 2009, 50 (17) :4189-4198
[40]   Optimization of antibiotic analysis in water by solid-phase extraction and high performance liquid chromatography-mass spectrometry/mass spectrometry [J].
Zhou, John L. ;
Maskaoui, Khalid ;
Lufadeju, Adeleye .
ANALYTICA CHIMICA ACTA, 2012, 731 :32-39