Incidence of Artifacts and Deviating Values in Research Data Obtained from an Anesthesia Information Management System in Children

被引:22
作者
Hoorweg, Anne-lee J. [1 ]
Pasma, Wietze [1 ]
van Wolfswinkel, Leo [1 ]
de Graaff, Jurgen C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Wilhelmina Childrens Hosp, Dept Anesthesia, Utrecht, Netherlands
关键词
BLOOD-PRESSURE-MEASUREMENTS; PHYSIOLOGICAL DEAD SPACE; PULSE OXIMETRY; IMPLEMENTATION; HYPOXEMIA; HEART; QUALITY; RECORDS; TIME; CARE;
D O I
10.1097/ALN.0000000000001895
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Vital parameter data collected in anesthesia information management systems are often used for clinical research. The validity of this type of research is dependent on the number of artifacts. Methods: In this prospective observational cohort study, the incidence of artifacts in anesthesia information management system data was investigated in children undergoing anesthesia for noncardiac procedures. Secondary outcomes included the incidence of artifacts among deviating and nondeviating values, among the anesthesia phases, and among different anesthetic techniques. Results: We included 136 anesthetics representing 10,236min of anesthesia time. The incidence of artifacts was 0.5% for heart rate (95% CI: 0.4 to 0.7%), 1.3% for oxygen saturation (1.1 to 1.5%), 7.5% for end-tidal carbon dioxide (6.9 to 8.0%), 5.0% for noninvasive blood pressure (4.0 to 6.0%), and 7.3% for invasive blood pressure (5.9 to 8.8%). The incidence of artifacts among deviating values was 3.1% for heart rate (2.1 to 4.4%), 10.8% for oxygen saturation (7.6 to 14.8%), 14.1% for end-tidal carbon dioxide (13.0 to 15.2%), 14.4% for noninvasive blood pressure (10.3 to 19.4%), and 38.4% for invasive blood pressure (30.3 to 47.1%). Conclusions: Not all values in anesthesia information management systems are valid. The incidence of artifacts stored in the present pediatric anesthesia practice was low for heart rate and oxygen saturation, whereas noninvasive and invasive blood pressure and end-tidal carbon dioxide had higher artifact incidences. Deviating values are more often artifacts than values in a normal range, and artifacts are associated with the phase of anesthesia and anesthetic technique. Development of (automatic) data validation systems or solutions to deal with artifacts in data is warranted.
引用
收藏
页码:293 / 304
页数:12
相关论文
共 37 条
[1]   Paperless anesthesia: uses and abuses of these data [J].
Anderson, Brian J. ;
Merry, Alan F. .
PEDIATRIC ANESTHESIA, 2015, 25 (12) :1184-1192
[2]   Defining and improving data quality in medical registries: A literature review, case study, and generic framework [J].
Arts, DGT ;
de Keizer, NF ;
Scheffer, GJ .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2002, 9 (06) :600-611
[3]   Lessons for pediatric anesthesia from audit and incident reporting [J].
Bell, Graham .
PEDIATRIC ANESTHESIA, 2011, 21 (07) :758-764
[4]   Development of Heart and Respiratory Rate Percentile Curves for Hospitalized Children [J].
Bonafide, Christopher P. ;
Brady, Patrick W. ;
Keren, Ron ;
Conway, Patrick H. ;
Marsolo, Keith ;
Daymont, Carrie .
PEDIATRICS, 2013, 131 (04) :E1150-E1157
[5]   Are pitfalls of oscillometric blood pressure measurements preventable in children? [J].
Butani, L ;
Morgenstern, BZ .
PEDIATRIC NEPHROLOGY, 2003, 18 (04) :313-318
[6]   Physiological dead space tidal volume ratio during face mask, laryngeal mask, and cuffed oropharyngeal airway spontaneous ventilation [J].
Casati, A ;
Fanelli, G ;
Torri, G .
JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (08) :652-655
[7]   Organizational Performance and Regulatory Compliance as Measured by Clinical Pertinence Indicators Before and After Implementation of Anesthesia Information Management System (AIMS) [J].
Choi, Clark K. ;
Saberito, Darlene ;
Tyagaraj, Changa ;
Tyagaraj, Kalpana .
JOURNAL OF MEDICAL SYSTEMS, 2014, 38 (01) :1-6
[8]   Reference Values for Noninvasive Blood Pressure in Children during Anesthesia A Multicentered Retrospective Observational Cohort Study [J].
de Graaff, Jurgen C. ;
Pasma, Wietze ;
Buuren, Stef van ;
Duijghuisen, Jesse J. ;
Nafiu, Olubukola O. ;
Kheterpal, Sachin ;
van Klei, Wilton A. .
ANESTHESIOLOGY, 2016, 125 (05) :904-913
[9]   Anesthesia-related critical incidents in the perioperative period in children; a proposal for an anesthesia-related reporting system for critical incidents in children [J].
de Graaff, Jurgen C. ;
Sarfo, Marie-christine ;
van Wolfswinkel, Leo ;
van der Werff, Desiree B. M. ;
Schouten, Antonius N. J. .
PEDIATRIC ANESTHESIA, 2015, 25 (06) :621-629
[10]   Incidence of Intraoperative Hypoxemia in Children in Relation to Age [J].
de Graaff, Jurgen C. ;
Bijker, Jilles B. ;
Kappen, T. H. ;
van Wolfswinkel, Leo ;
Zuithoff, Nicolaas P. A. ;
Kalkman, Cor J. .
ANESTHESIA AND ANALGESIA, 2013, 117 (01) :169-175