Measurement of thickness and density of thin structures by computed tomography: A simulation study

被引:67
作者
Dougherty, G [1 ]
Newman, D [1 ]
机构
[1] Kuwait Univ, Fac Allied Hlth Sci, Dept Radiol Sci, Kuwait, Kuwait
关键词
quantitative computed tomography; spatial resolution; vertebral strength; digital convolution;
D O I
10.1118/1.598629
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Limited spatial resolution of clinical CT systems causes difficulties in the measurement of the density and thickness of thin structures such as the vertebral cortical shell. We simulated the imaging process by convolving experimentally determined point spread functions with rectangular and Gaussian profiles, for various fields of view or pixel sizes and reconstruction kernels. The simulations successfully explained the reported overestimation of thickness and underestimation of density when imaging thin structures. Both effects are larger for Gaussian profiles. For the rectangular profiles, experimental estimates of thickness and density will only be accurate when the true thickness is greater than about 1.5 times (for the bone reconstruction kernel) or 2.0 times (for the standard kernel) the full width at half maximum of the point spread function (PSF) of the imaging system. For Gaussian profiles imaged by a system with a Gaussian PSF, there are straightforward analytical expressions for the overestimation of thickness and underestimation of density: and these are useful approximations to the simulations of Gaussian profiles with experimental (pseudo-Gaussian) PSFs. We have demonstrated that thresholding of the vertebral image cannot provide accurate estimates of cortical thickness and density because the appropriate threshold level requires foreknowledge of the cortical thickness. To circumvent such difficulties we suggest that the average value of the peak CT numbers measured along the medial axis of the cortical shell be adopted as an index of cortical shell strength, since its value depends on both the density and the thickness of the shell. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00507-6].
引用
收藏
页码:1341 / 1348
页数:8
相关论文
共 24 条
[1]  
BLUMENFELD SM, 1981, RADIOLOGY SKULL BRAI, V5, P3918
[2]  
Erhardt JC, 1986, MED PHYS, V13, P658
[3]   EFFECT OF BONE DISTRIBUTION ON VERTEBRAL STRENGTH - ASSESSMENT WITH PATIENT-SPECIFIC NONLINEAR FINITE-ELEMENT ANALYSIS [J].
FAULKNER, KG ;
CANN, CE ;
HASEGAWA, BH .
RADIOLOGY, 1991, 179 (03) :669-674
[4]   THE ASSESSMENT OF VERTEBRAL BONE MACROARCHITECTURE WITH X-RAY COMPUTED-TOMOGRAPHY [J].
FLYNN, MJ ;
CODY, DD .
CALCIFIED TISSUE INTERNATIONAL, 1993, 53 :S170-S175
[5]   INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .1. MODULATION TRANSFER-FUNCTION [J].
GIGER, ML ;
DOI, K .
MEDICAL PHYSICS, 1984, 11 (03) :287-295
[6]   Evaluation of cortical bone by computed tomography [J].
Hangartner, TN ;
Gilsanz, V .
JOURNAL OF BONE AND MINERAL RESEARCH, 1996, 11 (10) :1518-1525
[7]   PERFORMANCE EVALUATION OF DENSITY-MEASUREMENTS OF AXIAL AND PERIPHERAL BONE WITH X-RAY AND GAMMA-RAY COMPUTED-TOMOGRAPHY [J].
HANGARTNER, TN ;
BATTISTA, JJ ;
OVERTON, TR .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (11) :1393-1406
[8]  
KALENDER WA, 1989, EUR J RADIOL, V9, P75
[9]   Cortical thickness assessed by peripheral quantitative computed tomography: Accuracy evaluated on radius specimens [J].
Louis, O ;
Willnecker, J ;
Soykens, S ;
VandenWinkel, P ;
Osteaux, M .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (06) :446-449
[10]  
LOUIS O, 1993, INVEST RADIOL, V28, P802