The effect of sampling site on the variability of Umbilical artery PI

被引:8
作者
Bhide, Amarnath [1 ]
Badade, Anirudh [2 ]
Khatal, Kalpesh [2 ]
机构
[1] St George Hosp, Fetal Med Unit, Lanesborough Wing 4th Floor,Blackshaw Rd, London SW17 0QT, England
[2] Chikitsa Diagnost & Ultrasound Training Ctr, 6,7 Mahinder Chambers,W T Patil Marg, Mumbai, Maharashtra, India
关键词
Umbilical artery Doppler; Variability; Prenatal ultrasound; PULSATILITY INDEX; FLOW-VELOCITY; DOPPLER; FETAL; INTRAOBSERVER; RELIABILITY; PREGNANCIES; GESTATION;
D O I
10.1016/j.ejogrb.2018.12.026
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction: To test the hypothesis that standardising the site of sampling of umbilical artery Doppler reduces the variability of umbilical artery Pulsatility Index (PI). Study design: In this prospective study, pregnant women with a singleton pregnancy and secure dating were invited to participate after 24 weeks of pregnancy. Using recommended technique, umbilical artery PI was measured from the free loop of the umbilical cord and from the para-vesical site by the same examiner at the beginning and the end of ultrasound examination in a state of fetal quiescence, generating four measurements per fetus. Variability of the measurements at the two sampling sites was tested using Pitman test of equality of variance for related samples. The difference between the two sets of measurements were plotted against the mean to generate limits of agreement. Results: A total of 158 women were recruited. Umbilical artery PI was significantly negatively correlated with the gestational age (r = 0.246 for free loop and 0.262 for para-vesical site, both p <0.005). The PI at the para-vesical site was significantly higher than in the free loop (p <0.001). Pitman's test showed that the total variability of umbilical artery PI at the two sites was no different (r = 0.091, p = 0.254). Conclusion: Measurement site contributes to an insignificant proportion to the total variability of the umbilical artery PI measurements. Umbilical artery PI is significantly lower when measured in the free loop as compared to the para-vesical site. Standardising the site of sampling does not improve the repeatability of umbilical artery PI measurement. Crown Copyright (C) 2019 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 105
页数:4
相关论文
共 17 条
[1]   Reference ranges for serial measurements of blood velocity and pulsatility index at the intra-abdominal portion, and fetal and placental ends of the umbilical artery [J].
Acharya, G ;
Wilsgaard, T ;
Berntsen, GKR ;
Maltau, JM ;
Kiserud, T .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (02) :162-169
[2]   Umbilical and fetal middle cerebral artery Doppler at 35-37 weeks' gestation in the prediction of adverse perinatal outcome [J].
Akolekar, R. ;
Syngelaki, A. ;
Gallo, D. M. ;
Poon, L. C. ;
Nicolaides, K. H. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 46 (01) :82-92
[3]  
[Anonymous], 2017, The Cochrane database of systematic reviews
[4]  
Badade Anirudh B, 2013, Indian J Radiol Imaging, V23, P266, DOI 10.4103/0971-3026.120270
[5]  
Bahlmann F, 2012, ULTRASCHALL MED, V33, P258, DOI [10.1055/s-0031-1281647, 10.1055/s-0031-1299294]
[6]   Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables [J].
Bartlett, J. W. ;
Frost, C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) :466-475
[7]   ISUOG Practice Guidelines: use of Doppler ultrasonography in obstetrics [J].
Bhide, A. ;
Acharya, G. ;
Bilardo, C. M. ;
Brezinka, C. ;
Cafici, D. ;
Hernandez-Andrade, E. ;
Kalache, K. ;
Kingdom, J. ;
Kiserud, T. ;
Lee, W. ;
Lees, C. ;
Leung, K. Y. ;
Malinger, G. ;
Mari, G. ;
Prefumo, F. ;
Sepulveda, W. ;
Trudinger, B. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 41 (02) :234-240
[8]   CHANGES OBSERVED IN DOPPLER STUDIES OF THE FETAL CIRCULATION IN PREGNANCIES COMPLICATED BY PREECLAMPSIA OR THE DELIVERY OF A SMALL-FOR-GESTATIONAL-AGE BABY .1. CROSS-SECTIONAL ANALYSIS [J].
HARRINGTON, K ;
CARPENTER, RG ;
NGUYEN, M ;
CAMPBELL, S .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 6 (01) :19-28
[9]  
Janeczek S, 2012, J ULTRAS MED, V31, P679
[10]   Variation in Doppler indices along the length of the cord from the intraabdominal to the placental insertion [J].
Khare, Manjiri ;
Paul, Sanjoy ;
Konje, Justin C. .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2006, 85 (08) :922-928