Fast and isocratic HPLC-method for steviol glycosides analysis from Stevia rebaudiana leaves

被引:37
作者
Bergs, Dominik [1 ]
Burghoff, Bernhard [1 ]
Joehnck, Matthias [2 ]
Martin, Georg [3 ]
Schembecker, Gerhard [1 ]
机构
[1] Tech Univ Dortmund, Lab Plant & Proc Design, Dept Biochem & Chem Engn, D-44227 Dortmund, Germany
[2] Merck KgaA, D-64293 Darmstadt, Germany
[3] LANXESS Deutschland GmbH, Leverkusen, Germany
来源
JOURNAL FUR VERBRAUCHERSCHUTZ UND LEBENSMITTELSICHERHEIT-JOURNAL OF CONSUMER PROTECTION AND FOOD SAFETY | 2012年 / 7卷 / 02期
关键词
HPLC; Steviol glycosides; Rebaudioside A; Stevioside; Validation; Isocractic analysis; LIQUID-CHROMATOGRAPHIC SEPARATION; THIN-LAYER-CHROMATOGRAPHY; REBAUDIOSIDE-A; DULCOSIDE-A; PLANT; QUANTITATION; FOOD;
D O I
10.1007/s00003-012-0760-5
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A fast isocratic HPLC method for analysis of steviol glycosides from Stevia rebaudiana leaves was developed with a high selectivity for nine known steviol glycosides and low eluent consumption. The analytical method was performed on a Purospher(A (R)) STAR RP-18 endcapped 3 mu m Hibar(A (R)) RT 250-4.6 column at 50 A degrees C with an eluent composition of water (65 vol. %) and acetonitrile (35 vol. %). With a flow rate of 1 mL min(-1), nine known steviol glycosides were detected selectively after 15 min. Method validation for rebaudioside A showed a LOD of 0.0004 mg mL(-1) and a LOQ of 0.0038 mg mL(-1). Particularly with regard to moderate solubility, the method is linear up to a concentration of rebaudioside A of 4.8 mg mL(-1). The linear calibration curve was obtained with a coefficient of determination of 0.9997 +/- A 0.0002 and a total error of 2.01 % RSD (n = 12). The accuracy of the method was determined by the percentage mean recovery rate to 100.99 +/- A 2.01 %. The intra-day precision was in a range of 0.12 to 1.96 % RSD and the inter-day precision varies from 0.02 to 1.89 % RSD. Small changes in operating conditions like eluent composition (65 +/- A 2 vol. %), temperature (50 +/- A 10 A degrees C) or flow rate (1 +/- A 0.2 mL min(-1)) do not affect the performance of the analytical method. The reliable and robust proposed HPLC method can be applied for quantification of steviol glycosides in Stevia rebaudiana Bertoni leaves in laboratories and quality control in industry.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 24 条
[1]  
ADDUCI J, 1987, J SCI SOC THAILAND, V13, P179
[2]  
AHMED MS, 1982, J CHROMATOGR, V236, P523, DOI [10.1016/S0021-9673(00)84907-9, 10.1016/S0021-9673(00)84908-0]
[3]   STEVIA-REBAUDIANA .3. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION AND QUANTITATION OF REBAUDIOSIDE-B, REBAUDIOSIDE-D, AND REBAUDIOSIDE-E, DULCOSIDE-A, AND STEVIOLBIOSIDE [J].
AHMED, MS ;
DOBBERSTEIN, RH .
JOURNAL OF CHROMATOGRAPHY, 1982, 245 (03) :373-376
[4]   HPLC determination of stevioside in plant material and food samples [J].
Bovanova, L ;
Brandsteterova, E ;
Baxa, S .
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG A-FOOD RESEARCH AND TECHNOLOGY, 1998, 207 (05) :352-355
[5]   Overview: The history, technical function and safety of rebaudioside A, a naturally occurring steviol glycoside, for use in food and beverages [J].
Carakostas, M. C. ;
Curry, L. L. ;
Boilea, A. C. ;
Brusick, Dj. .
FOOD AND CHEMICAL TOXICOLOGY, 2008, 46 (07) :S1-S10
[6]  
CRAMMER B, 1986, CHEM BRIT, V22, P915
[7]   Sweet diterpenic glycosides balance of a new cultivar of Stevia rebaudiana (Bert.) Bertoni:: Isolation and quantitative distribution by chromatographic, spectroscopic, and electrophoretic methods [J].
Dacome, AS ;
da Silva, CC ;
da Costa, CEM ;
Fontana, JD ;
Adelmann, J ;
da Costa, SC .
PROCESS BIOCHEMISTRY, 2005, 40 (11) :3587-3594
[8]  
FAO, 2010, FAO JECFA MON, V10
[9]   Evaluation of steviol and its glycosides in Stevia rebaudiana leaves and commercial sweetener by ultra-high-performance liquid chromatography-mass spectrometry [J].
Gardana, Claudio ;
Scaglianti, Martina ;
Simonetti, Paolo .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (09) :1463-1470
[10]  
HASHIMOTO Y, 1978, J CHROMATOGR, V161, P403, DOI 10.1016/S0021-9673(01)85262-6