Detection of hydrogen peroxide in Photosystem II (PSII) using catalytic amperometric biosensor

被引:17
作者
Prasad, Ankush [1 ]
Kumar, Aditya [2 ]
Suzuki, Makoto [3 ]
Kikuchi, Hiroyuki [3 ]
Sugai, Tomoya [3 ]
Kobayashi, Masaki [1 ,4 ]
Pospisil, Pavel [2 ]
Tada, Mika [1 ,5 ]
Kasai, Shigenobu [1 ,3 ]
机构
[1] Tohoku Inst Technol, Biomed Engn Res Ctr, Sendai, Miyagi 982, Japan
[2] Palacky Univ, Dept Biophys, Fac Sci, Ctr Reg Hana Biotechnol & Agr Res, CR-77147 Olomouc, Czech Republic
[3] Tohoku Inst Technol, Grad Dept Environm Informat Engn, Sendai, Miyagi 982, Japan
[4] Tohoku Inst Technol, Grad Dept Elect, Sendai, Miyagi 982, Japan
[5] Tohoku Inst Technol, Ctr Gen Educ, Sendai, Miyagi 982, Japan
来源
FRONTIERS IN PLANT SCIENCE | 2015年 / 6卷
关键词
photosystem II; superoxide anion radical; hydrogen peroxide; reactive oxygen species; amperometric biosensor; EPR-spin trapping; LABELED NANO-AU; HORSERADISH-PEROXIDASE; SUPEROXIDE-PRODUCTION; CYTOCHROME B(559); SINGLET OXYGEN; IMMOBILIZATION; STRESS; NANOPARTICLES; ELECTRODE; FERROCENE;
D O I
10.3389/fpls.2015.00862
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Hydrogen peroxide (H2O2) is known to be generated in Photosystem II (PSII) via enzymatic and non-enzymatic pathways. Detection of H2O2 by different spectroscopic techniques has been explored, however its sensitive detection has always been a challenge in photosynthetic research. During the recent past, fluorescence probes such as Amplex Red (AR) has been used but is known to either lack specificity or limitation with respect to the minimum detection limit of H2O2. We have employed an electrochemical biosensor for real time monitoring of H2O2 generation at the level of sub-cellular organelles. The electrochemical biosensor comprises of counter electrode and working electrodes. The counter electrode is a platinum plate, while the working electrode is a mediator based catalytic amperometric biosensor device developed by the coating of a carbon electrode with osmium-horseradish peroxidase which acts as H2O2 detection sensor. In the current study, generation and kinetic behavior of H2O2 in PSII membranes have been studied under light illumination. Electrochemical detection of H2O2 using the catalytic amperometric biosensor device is claimed to serve as a promising technique for detection of H2O2 in photosynthetic cells and subcellular structures including PSII or thylakoid membranes. It can also provide a precise information on qualitative determination of H2O2 and thus can be widely used in photosynthetic research.
引用
收藏
页数:10
相关论文
共 73 条
  • [1] Ahammad J.S., 2013, J BIOSENS BIOELECTRO, V9, P1, DOI [DOI 10.4172/2155-6210.S9-001, 10.4172/2155-6210.S9-001]
  • [2] THE PHOTOPRODUCTION OF SUPEROXIDE RADICALS AND THE SUPEROXIDE-DISMUTASE ACTIVITY OF PHOTOSYSTEM-II - THE POSSIBLE INVOLVEMENT OF CYTOCHROME B559
    ANANYEV, G
    RENGER, G
    WACKER, U
    KLIMOV, V
    [J]. PHOTOSYNTHESIS RESEARCH, 1994, 41 (02) : 327 - 338
  • [3] Production of reactive oxygen species in chloride- and calcium-depleted photosystem II and their involvement in photoinhibition
    Arató, A
    Bondarava, N
    Krieger-Liszkay, A
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2004, 1608 (2-3): : 171 - 180
  • [4] A HIGHLY RESOLVED, OXYGEN-EVOLVING PHOTOSYSTEM-II PREPARATION FROM SPINACH THYLAKOID MEMBRANES - ELECTRON-PARAMAGNETIC-RES AND ELECTRON-TRANSPORT PROPERTIES
    BERTHOLD, DA
    BABCOCK, GT
    YOCUM, CF
    [J]. FEBS LETTERS, 1981, 134 (02) : 231 - 234
  • [5] The apoplastic oxidative burst in response to biotic stress in plants: a three-component system
    Bolwell, GP
    Bindschedler, LV
    Blee, KA
    Butt, VS
    Davies, DR
    Gardner, SL
    Gerrish, C
    Minibayeva, F
    [J]. JOURNAL OF EXPERIMENTAL BOTANY, 2002, 53 (372) : 1367 - 1376
  • [6] Amperometric biosensor for hydrogen peroxide, using supramolecularly immobilized horseradish peroxidase on the β-cyclodextrin-coated gold electrode
    Camacho, Conrado
    Matias, Juan C.
    Chico, Belkis
    Cao, Roberto
    Gomez, Leissy
    Simpson, Benjamin K.
    Villalonga, Reynaldo
    [J]. ELECTROANALYSIS, 2007, 19 (24) : 2538 - 2542
  • [7] Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase (HRP) on the layer-by-layer assembly films of gold colloidal nanoparticles and toluidine blue
    Chen, SH
    Yuan, R
    Chai, YQ
    Xu, L
    Wang, N
    Li, XN
    Zhang, LY
    [J]. ELECTROANALYSIS, 2006, 18 (05) : 471 - 477
  • [8] Reactive oxygen species from chloroplasts contribute to 3-acetyl-5-isopropyltetramic acid-induced leaf necrosis of Arabidopsis thaliana
    Chen, Shiguo
    Yin, Chunyan
    Strasser, Reto Joerg
    Govindjee
    Yang, Chunlong
    Qiang, Sheng
    [J]. PLANT PHYSIOLOGY AND BIOCHEMISTRY, 2012, 52 : 38 - 51
  • [9] Chemiluminescence flow biosensor for hydrogen peroxide using DNAzyme immobilized on eggshell membrane as a thermally stable biocatalyst
    Chen, Weiwei
    Li, Baoxin
    Xu, Chunli
    Wang, Lei
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) : 2534 - 2540
  • [10] Voltammetric detection of superoxide production by photosystem II
    Cleland, RE
    Grace, SC
    [J]. FEBS LETTERS, 1999, 457 (03) : 348 - 352