Breast MRI and X-ray mammography registration using gradient values

被引:18
作者
Garcia, Eloy [1 ]
Diez, Yago [2 ]
Diaz, Oliver [1 ]
Llado, Xavier [1 ]
Gubern-Merida, Albert [3 ]
Marti, Robert [1 ]
Marti, Joan [1 ]
Oliver, Arnau [1 ]
机构
[1] Univ Girona, Inst Comp Vis & Robot, Girona, Spain
[2] Yamagata Univ, Fac Sci, Dept Math Sci, Yamagata, Japan
[3] Radboud Univ Nijmegen, Med Ctr, NL-6525 GA Nijmegen, Netherlands
基金
欧盟地平线“2020”;
关键词
Breast cancer; Multimodal registration; X-ray mammography; MRI; MODELS; OPTIMIZATION; IMAGES;
D O I
10.1016/j.media.2019.02.013
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Breast magnetic resonance imaging (MRI) and X-ray mammography are two image modalities widely used for early detection and diagnosis of breast diseases in women. The combination of these modalities, traditionally done using intensity-based registration algorithms, leads to a more accurate diagnosis and treatment, due to the capability of co-localizing lesions and susceptibles areas between the two image modalities. In this work, we present the first attempt to register breast MRI and X-ray mammographic images using intensity gradients as the similarity measure. Specifically, a patient-specific biomechanical model of the breast, extracted from the MRI image, is used to mimic the mammographic acquisition. The intensity gradients of the glandular tissue are directly projected from the 3D MRI volume to the 2D mammographic space, and two different gradient-based metrics are tested to lead the registration, the normalized cross-correlation of the scalar gradient values and the gradient correlation of the vectoral gradients. We compare these two approaches to an intensity-based algorithm, where the MRI volume is transformed to a synthetic computed tomography (pseudo-CT) image using the partial volume effect obtained by the glandular tissue segmentation performed by means of an Expectation-Maximization algorithm. This allows us to obtain the digitally reconstructed radiographies by a direct intensity projection. The best results are obtained using the scalar gradient approach along with a transversal isotropic material model, obtaining a target registration error (TRE), in millimeters, of 5.65 +/- 2.76 for CC- and of 7.83 +/- 3.04 for MLO-mammograms, while the TRE is 7.33 +/- 3.62 in the 3D MRI. We also evaluate the effect of the glandularity of the breast as well as the landmark position on the TRE, obtaining moderated correlation values (0.65 and 0.77 respectively), concluding that these aspects need to be considered to increase the accuracy in further approaches. (C) 2019 The Authors. Published by Elsevier B.V.
引用
收藏
页码:76 / 87
页数:12
相关论文
共 43 条
  • [1] [Anonymous], 1987, PROC INT C COMPUT GR, DOI [10.1145/37401.37422, DOI 10.1145/37402.37422, DOI 10.1145/37401.37422]
  • [2] [Anonymous], AUTOMATICA
  • [3] [Anonymous], MED PHYS
  • [4] A deformable finite element model of the breast for predicting mechanical deformations under external perturbations
    Azar, FS
    Metaxas, DN
    Schnall, MD
    [J]. ACADEMIC RADIOLOGY, 2001, 8 (10) : 965 - 975
  • [5] Bonet J., 1997, Nonlinear continuum mechanics for finite element analysis
  • [6] Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    Boone, JM
    Fewell, TR
    Jennings, RJ
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 1863 - 1874
  • [7] Chung, 2008, THESIS
  • [8] Eiben B., 2014, SPIE MED IMAGING IMA, V9036
  • [9] Breast MRI artefacts: Evaluation and solutions in 630 consecutive patients
    Fiaschetti, V.
    Pistolese, C. A.
    Funel, V.
    Rascioni, M.
    Claroni, G.
    Della Gatta, F.
    Cossu, E.
    Perretta, T.
    Simonetti, G.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (11) : E601 - E608
  • [10] Fung Y.C., 2013, Biomechanics: Mechanical Properties of Living Tissues