Deep learning from dual-energy information for whole-heart segmentation in dual-energy and single-energy non-contrast-enhanced cardiac CT

被引:38
作者
Bruns, Steffen [1 ,2 ,3 ]
Wolterink, Jelmer M. [1 ,2 ,3 ]
Takx, Richard A. P. [4 ]
van Hamersvelt, Robbert W. [4 ]
Sucha, Dominika [4 ]
Viergever, Max A. [2 ]
Leiner, Tim [4 ]
Isgum, Ivana [1 ,2 ,3 ,5 ]
机构
[1] Univ Amsterdam, Locat AMC, Amsterdam UMC, Dept Biomed Engn & Phys, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Med Ctr Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[3] Amsterdam UMC, Amsterdam Cardiovasc Sci, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[5] Amsterdam UMC, Locat AMC, Dept Radiol & Nucl Med, NL-1105 AZ Amsterdam, Netherlands
关键词
cardiac CT; convolutional neural network; deep learning; non-contrast-enhanced CT; whole-heart segmentation; LEFT-VENTRICULAR MASS; AUTOMATIC SEGMENTATION; ATRIAL VOLUME; ANGIOGRAPHY; RISK; QUANTIFICATION; ATTENUATION; VALUES;
D O I
10.1002/mp.14451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Deep learning-based whole-heart segmentation in coronary computed tomography angiography (CCTA) allows the extraction of quantitative imaging measures for cardiovascular risk prediction. Automatic extraction of these measures in patients undergoing only non-contrast-enhanced CT (NCCT) scanning would be valuable, but defining a manual reference standard that would allow training a deep learning-based method for whole-heart segmentation in NCCT is challenging, if not impossible. In this work, we leverage dual-energy information provided by a dual-layer detector CT scanner to obtain a reference standard in virtual non-contrast (VNC) CT images mimicking NCCT images, and train a three-dimensional (3D) convolutional neural network (CNN) for the segmentation of VNC as well as NCCT images. Methods Eighteen patients were scanned with and without contrast enhancement on a dual-layer detector CT scanner. Contrast-enhanced acquisitions were reconstructed into a CCTA and a perfectly aligned VNC image. In each CCTA image, manual reference segmentations of the left ventricular (LV) myocardium, LV cavity, right ventricle, left atrium, right atrium, ascending aorta, and pulmonary artery trunk were obtained and propagated to the corresponding VNC image. These VNC images and reference segmentations were used to train 3D CNNs in a sixfold cross-validation for automatic segmentation in either VNC images or NCCT images reconstructed from the non-contrast-enhanced acquisition. Automatic segmentation in VNC images was evaluated using the Dice similarity coefficient (DSC) and average symmetric surface distance (ASSD). Automatically determined volumes of the cardiac chambers and LV myocardium in NCCT were compared to reference volumes of the same patient in CCTA by Bland-Altman analysis. An additional independent multivendor multicenter set of single-energy NCCT images from 290 patients was used for qualitative analysis, in which two observers graded segmentations on a five-point scale. Results Automatic segmentations in VNC images showed good agreement with reference segmentations, with an average DSC of 0.897 +/- 0.034 and an average ASSD of 1.42 +/- 0.45 mm. Volume differences [95% confidence interval] between automatic NCCT and reference CCTA segmentations were -19 [-67; 30] mL for LV myocardium, -25 [-78; 29] mL for LV cavity, -29 [-73; 14] mL for right ventricle, -20 [-62; 21] mL for left atrium, and -19 [-73; 34] mL for right atrium, respectively. In 214 (74%) NCCT images from the independent multivendor multicenter set, both observers agreed that the automatic segmentation was mostly accurate (grade 3) or better. Conclusion Our automatic method produced accurate whole-heart segmentations in NCCT images using a CNN trained with VNC images from a dual-layer detector CT scanner. This method might enable quantification of additional cardiac measures from NCCT images for improved cardiovascular risk prediction.
引用
收藏
页码:5048 / 5060
页数:13
相关论文
共 34 条
[1]   Feasibility of automatic assessment of four-chamber cardiac function with MDCT: Initial clinical application and validation [J].
Abadi, Sobhi ;
Roguin, Ariel ;
Engel, Ahuva ;
Lessick, Jonathan .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (01) :175-181
[2]   Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT [J].
Ananthakrishnan, Lakshmi ;
Rajiah, Prabhakar ;
Ahn, Richard ;
Rassouli, Negin ;
Xi, Yin ;
Soesbe, Todd C. ;
Lewis, Matthew A. ;
Lenkinski, Robert E. ;
Leyendecker, John R. ;
Abbara, Suhny .
ABDOMINAL RADIOLOGY, 2017, 42 (03) :702-709
[3]   Improving Myocardium Segmentation in Cardiac CT Angiography using Spectral Information [J].
Bruns, Steffen ;
Wolterink, Jelmer M. ;
van Hamersvelt, Robbert W. ;
Zreik, Majd ;
Leiner, Tim ;
Isgum, Ivana .
MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949
[4]   The Effects of Iodine Attenuation on Pulmonary Nodule Volumetry using Novel Dual-Layer Computed Tomography Reconstructions [J].
den Harder, A. M. ;
Bangert, F. ;
van Hamersvelt, R. W. ;
Leiner, T. ;
Milles, Julien ;
Schilham, A. M. R. ;
Willemink, M. J. ;
de Jong, P. A. .
EUROPEAN RADIOLOGY, 2017, 27 (12) :5244-5251
[5]   Multislice CT coronary angiography: Effect of sublingual nitroglycerine on the diameter of coronary arteries [J].
Dewey, M. ;
Hoffmann, H. ;
Hamm, B. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (06) :600-604
[6]   Automated Three-dimensional Quantification of Noncalcified Coronary Plaque from Coronary CT Angiography: Comparison with Intravascular US [J].
Dey, Damini ;
Schepis, Tiziano ;
Marwan, Mohamed ;
Slomka, Piotr J. ;
Berman, Daniel S. ;
Achenbach, Stephan .
RADIOLOGY, 2010, 257 (02) :516-522
[7]   Left ventricular mass and geometry and the risk of ischemic stroke [J].
Di Tullio, MR ;
Zwas, DR ;
Sacco, RL ;
Sciacca, RR ;
Homma, S .
STROKE, 2003, 34 (10) :2380-2384
[8]   Automatic model-based segmentation of the heart in CT images [J].
Ecabert, Olivier ;
Peters, Jochen ;
Schramm, Hauke ;
Lorenz, Cristian ;
von Berg, Jens ;
Walker, Matthew J. ;
Vembar, Mani ;
Olszewski, Mark E. ;
Subramanyan, Krishna ;
Lavi, Guy ;
Weese, Juergen .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) :1189-1201
[9]   Feasibility of multi-atlas cardiac segmentation from thoracic planning CT in a probabilistic framework [J].
Finnegan, Robert ;
Dowling, Jason ;
Koh, Eng-Siew ;
Tang, Simon ;
Otton, James ;
Delaney, Geoff ;
Batumalai, Vikneswary ;
Luo, Carol ;
Atluri, Pramukh ;
Satchithanandha, Athiththa ;
Thwaites, David ;
Holloway, Lois .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08)
[10]   Normal values of left ventricular mass and cardiac chamber volumes assessed by 320-detector computed tomography angiography in the Copenhagen General Population Study [J].
Fuchs, Andreas ;
Mejdahl, Mads R. ;
Kuhl, J. Tobias ;
Stisen, Zara R. ;
Nilsson, Emma Julia P. ;
Kober, Lars V. ;
Nordestgaard, Borge G. ;
Kofoed, Klaus F. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (09) :1009-1017