Performance of the fixed-bed of granular activated carbon for the removal of pesticides from water supply

被引:15
作者
de Almeida Alves, Alcione Aparecida [1 ,2 ]
de Oliveira Ruiz, Giselle Louise [3 ]
Martins Nonato, Thyara Campos [1 ]
Mueller, Laura Cecilia [1 ]
Sens, Mauricio Luiz [1 ]
机构
[1] Univ Fed Santa Catarina, Programa Posgrad Engn Ambiental, Campus Univ UFSC CTC Bairro Trindade, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Fronteira Sul, Lab Aguas & Ecotoxicol, Rua Jacob Reinaldo Haupenthal 1580, BR-97900000 Cerro Largo, RS, Brazil
[3] Univ Fed Santa Catarina, Dept Engn Civil, Campus Univ UFSC CTC Bairro Trindade, Florianopolis, SC, Brazil
关键词
Adsorption; carbamates; carbaryl; methomyl; carbofuran; ADSORPTION;
D O I
10.1080/09593330.2018.1435731
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The application of a fixed bed adsorption column of granular activated carbon (FBAC-GAC), in the removal of carbaryl, methomyl and carbofuran at a concentration of 25 mu g L-1 for each carbamate, from the public water supply was investigated. For the determination of the presence of pesticides in the water supply, the analytical technique of high-performance liquid chromatography with post-column derivatization was used. Under conditions of constant diffusivity, the FBAC-GAC was saturated after 196 h of operation on a pilot scale. The exhaust rate of the granular activated carbon (GAC) in the FBAC-GAC until the point of saturation was 0.02 kg GAC m(-3) of treated water. By comparing a rapid small-scale column test and FBAC-GAC, it was confirmed that the predominant intraparticle diffusivity in the adsorption column was constant diffusivity. Based on the results obtained on a pilot scale, it was possible to estimate the values to be applied in the FBAC-GAC (full scale) to remove the pesticides, which are particle size with an average diameter of 1.5 mm GAC; relationship between the internal diameter of the column and the average diameter of GAC >= 50 in order to avoid preferential flow near the adsorption column wall; surface application rate 240 m(3) m(-2) d(-1) and an empty bed contact time of 3 min. ABBREVIATIONS: BV: bed volume; CD: constant diffusivity; EBCT: empty bed contact time; FBAC-GAC: fixed bed adsorption column of granular activated carbon; GAC: granular activated carbon; MPV: maximum permitted values; NOM: natural organic matter; PD: proportional diffusivity; pH(PCZ): pH of the zero charge point; SAR: surface application rate; RSSCT: rapid small-scale column test; WTCS: water treated conventional system
引用
收藏
页码:1977 / 1987
页数:11
相关论文
共 42 条
[1]   ESTERS OF CARBAMIC ACID [J].
ADAMS, P ;
BARON, FA .
CHEMICAL REVIEWS, 1965, 65 (05) :567-&
[2]  
Agencia Nacional de Vigilancia Sanitaria, 2017, MON AGR
[3]  
American Society for Testing and Materials (ASTM), 2014, D6586032014 ASTM
[4]  
American Society for Testing and Materials (ASTM), 2011, D2866112011 ASTM
[5]  
American Society for Testing and Materials (ASTM), 2014, D5832982014 ASTM
[6]  
American Society for Testing and Materials (ASTM), 2014, D2867092014 ASTM
[7]  
American Society for Testing and Materials (ASTM), 2017, D3838052017 ASTM
[8]  
[Anonymous], 2003, SUMM GUID CAN DRINK
[9]  
[Anonymous], 2006, 57509 GBT AQSIQ
[10]  
[Anonymous], 2005, Standard