Energy steering of biphasic waveforms using a transvenous three electrode system

被引:1
作者
Leonelli, FM
Wang, KE
King, C
Brewer, J
Donohoo, AM
Kroll, MW
机构
[1] Univ Kentucky, Div Cardiovasc Med, Lexington, KY USA
[2] Survival Link, Minneapolis, MN USA
[3] St Jude Med Co, St Paul, MN USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 06期
关键词
defibrillation; ventricular fibrillation; implantable cardioverter defibrillator;
D O I
10.1111/j.1540-8159.1999.tb06807.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The optimal electrode configuration for endocardial defibrillation is still a matter of debate. Current data suggests that a two path way configuration using the right ventricle (RV) as cathode and a common anode constituted by a superior vena cava (SVC) and a pectoral can (C) is the most effective combination. This may be related to the more uniform voltage gradient created by shocks delivered using this configuration. We hypothesized that more effective waveforms could be obtained by varying the distribution of the shock current between the two pathways of a three electrode endocardial defibrillation system. In 12 pigs, we compared the characteristics and the defibrillation efficacy of six biphasic waveforms discharged using either a two (RV --> C) or a three (RV --> SVC + C) electrode combination with the following configurations: Configuration 1 (W1): the RV apical coil was used as a cathode and the subcutaneous C as anode (RV --> C). Configuration 2 (W2): The RV was used as cathode and the combination of the atriocaval coil (SVC) and the subcutaneous C as anode (RV --> SVC + C). Configuration 3 (W3): The RV --> C was used for the first 25% of f + and RV --> SVC + C for the remainder of the discharge including f 2. Configuration 4 (W4): The RV --> C was used for the first 50% of f + and RV --> SVC + C for the remainder of the discharge including f 2. Configuration 5 (W5): The RV --> C was used for the first 75% of f + and RV --> SVC + C for the remainder of the discharge including f 2. Configuration 6 (W6): The RV --> C was used for f + and RV --> SVC + C for f 2. As an increasing fraction of the waveform was discharged using the RV --> SVC + C pathways, the impedance and the pulse width decreased while the tilt, the peak, and the average current significantly increased. The waveforms delivered using the RV --> SVC + C configuration for 100% or 75% of their duration had significantly lower stored energy DFT than the other waveform. Current distribution between three endocardial electrodes can be altered during the shock and generates waveforms with different characteristics. Shocks with 75% or more of the current flowing to the RV --> SVC + C required the lowest stored energy to defibrillate, This method of energy steering could be used to optimize current delivery in a three electrodes system.
引用
收藏
页码:849 / 854
页数:6
相关论文
共 16 条
[1]   PROSPECTIVE, RANDOMIZED COMPARISON IN HUMANS OF A UNIPOLAR DEFIBRILLATION SYSTEM WITH THAT USING AN ADDITIONAL SUPERIOR VENA-CAVA ELECTRODE [J].
BARDY, GH ;
DOLACK, GL ;
KUDENCHUK, PJ ;
POOLE, JE ;
MEHRA, R ;
JOHNSON, G .
CIRCULATION, 1994, 89 (03) :1090-1093
[2]   THE POTENTIAL GRADIENT FIELD CREATED BY EPICARDIAL DEFIBRILLATION ELECTRODES IN DOGS [J].
CHEN, PS ;
WOLF, PD ;
CLAYDON, FJ ;
DIXON, EG ;
VIDAILLET, HJ ;
DANIELEY, ND ;
PILKINGTON, TC ;
IDEKER, RE .
CIRCULATION, 1986, 74 (03) :626-636
[3]   THE DEFIBRILLATION THRESHOLD - A COMPARISON OF ANESTHETICS AND MEASUREMENT METHODS [J].
GILL, RM ;
SWEENEY, RJ ;
REID, PR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (04) :708-714
[4]  
IDEKER RE, 1991, CARDIAC PACING ELECT, P713
[5]   INTERNAL CARDIAC DEFIBRILLATION IN MAN - PRONOUNCED IMPROVEMENT WITH SEQUENTIAL PULSE DELIVERY TO 2 DIFFERENT LEAD ORIENTATIONS [J].
JONES, DL ;
KLEIN, GJ ;
GUIRAUDON, GM ;
SHARMA, AD ;
KALLOK, MJ ;
BOURLAND, JD ;
TACKER, WA .
CIRCULATION, 1986, 73 (03) :484-491
[6]  
KALLOK MJ, 1985, J AM COLL CARDIOL, V5, P456
[7]   A MINIMAL MODEL OF THE SINGLE CAPACITOR BIPHASIC DEFIBRILLATION WAVE-FORM [J].
KROLL, MW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11) :1782-1792
[8]   AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION WITHOUT THORACOTOMY USING AN ENDOCARDIAL AND SUBMUSCULAR PATCH SYSTEM [J].
MCCOWAN, R ;
MALONEY, J ;
WILKOFF, B ;
SIMMONS, T ;
KHOURY, D ;
MCALISTER, H ;
MORANT, V ;
CASTLE, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) :415-421
[9]   Does an SVC electrode further reduce DFT in a hot-can ICD system? [J].
Mouchawar, GA ;
Wolsleger, WK ;
Doan, PD ;
Causey, JD ;
Kroll, MW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :163-167
[10]   A PROSPECTIVE EVALUATION OF SINGLE AND DUAL CURRENT PATHWAYS FOR TRANSVENOUS CARDIOVERSION IN RAPID VENTRICULAR-TACHYCARDIA [J].
SAKSENA, S ;
CALVO, RA ;
PANTOPOULOS, D ;
GADHOKE, A ;
ROTHBART, ST .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05) :1130-1141