Pen-type laser fluorescence device versus bitewing radiographs for caries detection on approximal surfaces

被引:12
作者
Bizhang, M. [1 ]
Wollenweber, N. [1 ]
Singh-Huesgen, P. [2 ]
Danesh, G. [3 ]
Zimmer, S. [1 ]
机构
[1] Univ Witten Herdecke, Dept Operat & Prevent Dent, Alfred Herrhausen Str 50, D-58448 Witten, Germany
[2] Heinrich Hein Univ Duesseldorf, Dept Operat & Prevent Dent & Periodont, Moorenstr 5, D-40225 Dusseldorf, Germany
[3] Univ Witten Herdecke, Dept Orthodont, Alfred Herrhausen Str 50, D-58448 Witten, Germany
关键词
Detection; Caries; Approximal; Pen-type laser fluorescence device; Sensitivity; Specificity; Radiography; Dentin caries; IN-VITRO PERFORMANCE; OCCLUSAL CARIES; PRIMARY MOLARS; PRIMARY TEETH; CARIOUS LESIONS; CLINICAL-PERFORMANCE; CONVENTIONAL METHODS; TOOTH SEPARATION; VISUAL EXAMINATION; PERMANENT MOLARS;
D O I
10.1186/s13005-016-0126-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The accurate detection of approximal caries is generally difficult. The aim of this study was to assess the ability of the pen-type laser fluorescence device (LF pen) to detect approximal carious lesions in comparison to bitewing radiographs (BW). Methods: Three hundred forty-one tooth surfaces were diagnosed in 20 patients with an average age of 26.70 (+/- 2.82) years. Each test tooth was sequentially assessed by a single calibrated examiner using visual inspection, BW, and the LF pen. Radiographs were used as the gold standard to calculate an appropriate cut-off. Results: Sensitivity, specificity and accuracy values for cut-off limits of 15, measured by the LF pen were compared using the chi(2) test (McNemar test). For approximal caries at D3 level, the highest values of specificity and sensitivity were observed for the LF pen at a cut-off value of 15 (96.8 and 83.0 %) and for visual inspection (99.3 and 4.3 %). Conclusion: Within the limitations of this study, dentin caries on approximal surfaces could be detected equally well by the LF pen as by the bitewing radiographs. Therefore, the LF pen can be recommended as an alternative to radiographs for the detection of approximal caries in a regular dental practice setting.
引用
收藏
页数:8
相关论文
共 48 条
[1]  
Akarsu Serdar, 2006, J Clin Dent, V17, P53
[2]   In vitro quantification of smooth surface caries with DIAGNOdent and the DIAGNOdent pen [J].
Aljehani, Abdulaziz ;
Yang, Lifang ;
Shi, Xie-Qi .
ACTA ODONTOLOGICA SCANDINAVICA, 2007, 65 (01) :60-63
[3]   Reliability and validity issues of laser fluorescence measurements in occlusal caries diagnosis [J].
Alwas-Danowska, HA ;
Plasschaert, AJM ;
Suliborski, S ;
Verdonschot, EH .
JOURNAL OF DENTISTRY, 2002, 30 (04) :129-134
[4]   A systematic review of the performance of methods for identifying carious lesions [J].
Bader, JD ;
Shugars, DA ;
Bonito, AJ .
JOURNAL OF PUBLIC HEALTH DENTISTRY, 2002, 62 (04) :201-213
[5]   Occlusal caries detection and quantification by DIAGNOdent and Electronic Caries Monitor:: in vitro comparison [J].
Bamzahim, M ;
Shi, XQ ;
Angmar-Månsson, B .
ACTA ODONTOLOGICA SCANDINAVICA, 2002, 60 (06) :360-364
[6]  
Banerjee A, 2004, AM J DENT, V17, P233
[7]  
Braga Mariana M, 2010, Dent Clin North Am, V54, P479, DOI 10.1016/j.cden.2010.03.006
[8]   In vitro performance of methods of approximal caries detection in primary molars [J].
Braga, Mariana Minatel ;
Morais, Caroline Carvalho ;
Satiko Nakama, Renata Cristina ;
Leamari, Victor Moreira ;
Siqueira, Walter Luiz ;
Mendes, Fausto Medeiros .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (04) :E35-E41
[9]   An in vitro Comparison of Detection Methods for Approximal Carious Lesions in Primary Molars [J].
Chawla, N. ;
Messer, L. B. ;
Adams, G. G. ;
Manton, D. J. .
CARIES RESEARCH, 2012, 46 (02) :161-169
[10]   A clinical study of a laser fluorescence device for the detection of approximal caries in primary molars [J].
Chen, Jianghao ;
Qin, Man ;
Ma, Wenli ;
Ge, Lihong .
INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2012, 22 (02) :132-138