Differences in biomechanical stability using various fibrin glue compositions for mesh fixation in endoscopic inguinal hernia repair

被引:13
作者
Schug-Pass, Christine [1 ]
Jacob, Dietmar A. [1 ]
Lippert, Hans [2 ]
Koeckerling, Ferdinand [1 ]
机构
[1] Vivantes Hosp Spandau, Ctr Minimally Invas Surg, Dept Surg, D-13585 Berlin, Germany
[2] Otto Von Guericke Univ, Dept Surg, D-39120 Magdeburg, Germany
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2012年 / 26卷 / 11期
关键词
Hernia; Endoscopic; Mesh; Fixation; Fibrin glue; SEALANT; MODEL;
D O I
10.1007/s00464-012-2339-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
In hernia surgery, mesh fixation with fibrin glue instead of tacks and sutures can demonstrably reduce postoperative morbidity without increasing recurrence rates. In some cases there are significant differences in the biomechanical properties, depending on the functional structure of the meshes. Furthermore, there are various fibrin glue products on the market and these are used for mesh fixation. This study compared the fixation strength of fibrin glues in combination with various meshes. Three different lightweight polypropylene meshes (TiMESH (TM) light, ULTRAPRO (TM), Optilene(A (R)) LP) were tested. All meshes were fixed using 2 ml of each of the three different fibrin glues (TISSUCOLA (R), QUIXIL(A (R)), EVICELA (R)) and tested for their biomechanical stability. The defect in the muscle tissue used was 45 mm for a mesh size of 10 x 15 cm. Measurements were conducted using a standardized stamp penetration test, while aiming not to use a fixation strength of less than 32 N. With TISSUCOL, the fixation of Optilene LP proved to be significantly better than that of TiMESH or ULTRAPRO (97.3 vs. 47.9 vs. 34.9 N, p < 0.001). With EVICEL, it was possible to also achieve good tissue fixation for the ULTRAPRO mesh, while the results obtained for Optilene and TiMESH were relatively poorer [114.7 vs. 92.4 N (p = 0.056), vs. 64.3 N (p < 0.001)]. With QUIXIL, satisfactory results were obtained only for Optilene LP (43.6 N). This study showed that there were significant differences in the fixation strength of different polypropylene meshes in combination with various fibrin glues. Experiments demonstrated that for each mesh there is an optimum combination with a particular fibrin glue with respect to the fixation strength. It must now be verified whether these results can be extrapolated to clinical practice.
引用
收藏
页码:3282 / 3286
页数:5
相关论文
共 8 条
  • [1] Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal Hernia [International Endohernia Society (IEHS)]
    Bittner, R.
    Arregui, M. E.
    Bisgaard, T.
    Dudai, M.
    Ferzli, G. S.
    Fitzgibbons, R. J.
    Fortelny, R. H.
    Klinge, U.
    Kockerling, F.
    Kuhry, E.
    Kukleta, J.
    Lomanto, D.
    Misra, M. C.
    Montgomery, A.
    Morales-Conde, S.
    Reinpold, W.
    Rosenberg, J.
    Sauerland, S.
    Schug-Pass, C.
    Singh, K.
    Timoney, M.
    Weyhe, D.
    Chowbey, P.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (09): : 2773 - 2843
  • [2] A Comparative Biomechanical Evaluation of Hernia Mesh Fixation by Fibrin Sealant
    Fortelny, Rene H.
    Petter-Puchner, Alexander H.
    Ferguson, James
    Gruber-Blum, Simone
    Brand, Julian
    Mika, Kathrin
    Redl, Heinz
    [J]. JOURNAL OF SURGICAL RESEARCH, 2011, 171 (02) : 576 - 581
  • [3] Different methods of mesh fixation in open retromuscular incisional hernia repair: a comparative study in pigs
    Grommes, J.
    Binneboesel, M.
    Klink, C. D.
    von Trotha, K. T.
    Junge, K.
    Conze, J.
    [J]. HERNIA, 2010, 14 (06) : 623 - 627
  • [4] Evaluation of intraperitoneal placement of absorbable and nonabsorbable barrier coated mesh secured with fibrin sealant in a New Zealand white rabbit model
    Jenkins, Eric D.
    Melman, Lora
    Desai, Salil
    Brown, Shaun R.
    Frisella, Margaret M.
    Deeken, Corey R.
    Matthews, Brent D.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (02): : 604 - 612
  • [5] Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair
    Katkhouda, N
    Mavor, E
    Friedlander, MH
    Mason, RJ
    Kiyabu, M
    Grant, SW
    Achanta, K
    Kirkman, EL
    Narayanan, K
    Essani, R
    [J]. ANNALS OF SURGERY, 2001, 233 (01) : 18 - 25
  • [6] Klinge U, 1996, CHIRURG, V67, P229
  • [7] Mesh fixation with fibrin glue (Tissucol/TisseelA®) in hernia repair dependent on the mesh structure-is there an optimum fibrin-mesh combination?-Investigations on a biomechanical model
    Schug-Pass, Christine
    Lippert, Hans
    Koeckerling, Ferdinand
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2010, 395 (05) : 569 - 574
  • [8] Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue
    ten Hallers, E. J. Olivier
    Jansen, John A.
    Marres, Henri A. M.
    Rakhorst, Gerhard
    Verkerke, Gijsbertus J.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 80A (02) : 372 - 380