Viscoelastic shear properties of the corneal stroma

被引:67
作者
Hatami-Marbini, Hamed [1 ]
机构
[1] Oklahoma State Univ, Sch Mech & Aerosp Engn, Stillwater, OK 74078 USA
关键词
Corneal stromal mechanics; Oscillatory torsional experiments; Linear viscoelastic behavior; Porcine cornea; SWELLING PRESSURE; BRAIN-TISSUE; MECHANICAL-PROPERTIES; ARTICULAR-CARTILAGE; BEHAVIOR; COLLAGEN; PARAMETERS; VIVO;
D O I
10.1016/j.jbiomech.2013.11.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The cornea is a highly specialized transparent tissue which covers the front of the eye. It is a tough tissue responsible for refracting the light and protecting the sensitive internal contents of the eye. The biomechanical properties of the cornea are primarily derived from its extracellular matrix, the stroma. The majority of previous studies have used strip tensile and pressure inflation testing methods to determine material parameters of the corneal stroma. Since these techniques do not allow measurements of the shear properties, there is little information available on transverse shear modulus of the cornea. The primary objectives of the present study were to determine the viscoelastic behavior of the corneal stroma in shear and to investigate the effects of the compressive strain. A thorough knowledge of the shear properties is required for developing better material models for corneal biomechanics. In the present study, torsional shear experiments were conducted at different levels of compressive strain (0-30%) on porcine corneal buttons. First, the range of linear viscoelasticity was determined from strain sweep experiments. Then, frequency sweep experiments with a shear strain amplitude of 0.2% (which was within the region of linear viscoelasticity) were performed. The corneal stroma exhibited viscoelastic properties in shear. The shear storage modulus, G', and shear loss modulus, G '', were reported as a function of tissue compression. It was found that although both of these parameters were dependent on frequency, shear strain amplitude, and compressive strain, the average shear storage and loss moduli varied from 2 to 8 kPa, and 0.3 to 1.2 kPa, respectively. Therefore, it can be concluded that the transverse shear modulus is of the same order of magnitude as the out-of-plane Young's modulus and is about three orders of magnitude lower than the in-plane Young's modulus. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:723 / 728
页数:6
相关论文
共 40 条
[1]   Application of structural analysis to the mechanical behaviour of the cornea [J].
Anderson, K ;
El-Sheikh, A ;
Newson, T .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2004, 1 (01) :3-15
[2]   A high-frequency shear device for testing soft biological tissues [J].
Arbogast, KB ;
Thibault, KL ;
Pinheiro, BS ;
Winey, KI ;
Margulies, SS .
JOURNAL OF BIOMECHANICS, 1997, 30 (07) :757-759
[3]  
Barnes H., 1989, An Introduction to Rheology
[4]   Linear viscoelastic properties of bovine brain tissue in smear [J].
Bilston, LE ;
Liu, ZZ ;
Nhan, PT .
BIORHEOLOGY, 1997, 34 (06) :377-385
[5]  
Bilston LE, 2001, BIORHEOLOGY, V38, P335
[6]   Stress-controlled viscoelastic tensile response of bovine cornea [J].
Boyce, B. L. ;
Jones, R. E. ;
Nguyen, T. D. ;
Grazier, J. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2367-2376
[7]  
Cheng X., 2013, COMPUTER MODELS BIOM, P11
[8]   Swelling of the collagen-keratocyte matrix of the bovine corneal stroma ex vivo in various solutions and its relationship to tissue thickness [J].
Doughty, MJ .
TISSUE & CELL, 2000, 32 (06) :478-493
[9]   Determination of the modulus of elasticity of the human cornea [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Pye, David .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (08) :808-818
[10]   Mechanical anisotropy of porcine cornea and correlation with stromal microstructure [J].
Elsheikh, Ahmed ;
Alhasso, Daad .
EXPERIMENTAL EYE RESEARCH, 2009, 88 (06) :1084-1091