Performance of a Cryogenic Michelson Interferometer

被引:1
|
作者
Lagueux, Philippe [1 ]
Chamberland, Martin [1 ]
Marcotte, Frederick [1 ]
Villemaire, Andre [1 ]
Duval, Marc [1 ]
Genest, Jerome [2 ]
Carter, Adriaan [3 ]
机构
[1] Telops Inc, 100-2600 St Jean Baptiste, Quebec City, PQ G2E 6J5, Canada
[2] Univ Laval, Dept Elect Engn, Quebec City, PQ G1K 7P4, Canada
[3] NIST, Gaithersburg, MD 20899 USA
来源
INFRARED SPACEBORNE REMOTE SENSING AND INSTRUMENTATION XVI | 2008年 / 7082卷
关键词
Spectrometer; cryogenic; infrared; interferometer; Michelson;
D O I
10.1117/12.798389
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cryogenic Fourier transform infrared spectrometer (Cryo-FTS) was developed for the Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology (NIST). This spectrometer was developed for the Missile Defense Agency Transfer Radiometer (MDXR) that will be used to calibrate infrared sources that cannot be transported to NIST for calibration. When used inside the MDXR, the Cryo-FTS provides relative spectral measurements with a repeatability better than 1% over the spectral range from 3 mu m to 15 mu m and at a spectral resolution of 0.6 cm(-1). This level of performance is enabled by the use of an advancec real-time resampling method. The compact interferometer uses a compensated Michelson configuration and has an operating temperature range between 10 K and 340 K with very low static beam redirection (< 215 mu rad). The interferometer uses flat mirrors and a KBr beamsplitter and compensator. This optics maintains low wavefront distortion for infrared beams of up to 2 cm diameter and 5 mrad divergence. It integrates a digitally servo-controlled porchswing mechanism to provide an accurate and repeatable optical path difference and is supported by a Wavefront Alignment (WA) system to correct for wavefront residual tilt in real time using a fibre optic coupled metrology system. The interferometer provides modulation efficiency of better than 44% with limited power dissipation (< 2.8 W) during operation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Performance of a Cryogenic Michelson Interferometer
    Lagueux, Philippe
    Chamberland, Martin
    Marcotte, Frederick
    Villemaire, Andre
    Duval, Marc
    Genest, Jerome
    Carter, Adriaan
    ADVANCED OPTICAL AND MECHANICAL TECHNOLOGIES IN TELESCOPES AND INSTRUMENTATION, PTS 1-3, 2008, 7018
  • [2] Design and development of a cryogenic Michelson interferometer
    Lagueux, Philippe
    Chamberland, Martin
    Marcotte, Frederick
    Villemaire, Andre
    INFRARED SPACEBORNE REMOTE SENSING XIV, 2006, 6297
  • [3] Design and development of a cryogenic Michelson interferometer - art. no. 669209
    Lagueux, Philippe
    Chamberland, Martin
    Marcotte, Frederick
    Villemaire, Andre
    CRYOGENIC OPTICAL SYSTEMS AND INSTRUMENTS XII, 2007, 6692 : 69209 - 69209
  • [4] THE MICHELSON INTERFEROMETER
    GIACOMO, P
    MIKROCHIMICA ACTA, 1987, 3 (1-6) : 19 - 31
  • [5] Collimation Factors and Performance Analysis Based on Michelson Interferometer
    Feng Mingchun
    Xu Liang
    Wang Yujie
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (13)
  • [6] Performance evaluation of a thermal Doppler Michelson interferometer system
    Mani, R
    Dobbie, S
    Scott, A
    Shepherd, G
    Gault, W
    Brown, S
    APPLIED OPTICS, 2005, 44 (33) : 7144 - 7155
  • [7] PERFORMANCE OF A MICHELSON INTERFEROMETER WITH ASYMMETRIC SURFACE DEFECTS DISTRIBUTION
    BHATNAGAR, GS
    CHOPRA, KN
    SINGH, K
    APPLIED OPTICS, 1974, 13 (07) : 1553 - 1554
  • [8] PERFORMANCE-CHARACTERISTICS OF A REFRACTIVELY SCANNED MICHELSON INTERFEROMETER
    DOYLE, WM
    MCINTOSH, BC
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 71 - 73
  • [9] MICHELSON INTERFEROMETER ALIGNMENT
    MOORE, FL
    AMERICAN JOURNAL OF PHYSICS, 1971, 39 (11) : 1395 - &
  • [10] MICHELSON AND HIS INTERFEROMETER
    SHANKLAND, RS
    PHYSICS TODAY, 1974, 27 (04) : 37 - +