Integral Fixation Titanium/Polyetheretherketone Cages for Cervical Arthrodesis: Evolution of Cage Design and Early Radiological Outcomes and Fusion Rates

被引:18
作者
Phan, Kevin [1 ,2 ,3 ,4 ,5 ]
Pelletier, Matthew H. [2 ]
Rao, Prashanth J. [1 ,3 ,4 ,5 ]
Choy, Wen Jie [1 ,3 ,5 ]
Walsh, William R. [2 ]
Mobbs, Ralph J. [1 ,3 ,4 ,5 ]
机构
[1] Univ New South Wales, Prince Wales Hosp, Randwick, NSW, Australia
[2] Prince Wales Hosp, Prince Wales Clin Sch, Surg & Orthopaed Res Labs, Randwick, NSW, Australia
[3] Prince Wales Hosp, Neuro Spine Clin, Randwick, NSW, Australia
[4] Prince Wales Hosp, Dept Spine Surg, Randwick, NSW, Australia
[5] Prince Wales Private Hosp, NSURG Res Grp, Sydney, NSW, Australia
关键词
Anterior cervical discectomy and fusion; Composite titanium/PEEK; Integral fixation ACDF cage; POLYETHERETHERKETONE PEEK CAGES; INTERBODY FUSION; TITANIUM-CAGES; MECHANICAL-PROPERTIES; DISKECTOMY; SUBSIDENCE; ALLOGRAFT; IMPLANTS; IMPROVE; DISEASE;
D O I
10.1111/os.12413
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective :To evaluate the initial outcomes of a composite cage with integral fixation using the Redmond titanium (Ti)/polyetheretherketone (PEEK) anterior cervical discectomy and fusion (ACDF) device. Methods: Data from 50 consecutive patients were prospectively collected from a single senior surgeon cohort. All cages were between 5 and 8 mm in height, and were packed with supercritical CO2 sterilized allograft. Patients were followed up for a minimum of 6 months, and implant complications were assessed. Results: From the original cohort, three were unavailable for follow-up. Forty-seven patients with a total of 58 operative levels were observed for a mean of 7.9 months. A fusion rate of 96% was achieved. Good to excellent outcomes were seen in 92% of patients. There were no cases of implant Ti/PEEK delamination or implant failure, with excellent early fusion rates using supercritical CO2 allograft. Conclusions: The present study demonstrates the development of a composite ACDF cage design that is a safe and effective treatment option with the potential for early osseointegration and interbody fusion. Supercritical CO2 sterilized allograft was an effective graft material supporting fusion.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 52 条
  • [11] The design evolution of interbody cages in anterior cervical discectomy and fusion: a systematic review
    Chong, Elizabeth
    Pelletier, Matthew H.
    Mobbs, Ralph J.
    Walsh, William R.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [12] Efficacy of anterior cervical fusion: Comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts
    Chou, Yu-Cheng
    Chen, Der-Cherng
    Hsieh, Wanhua Annie
    Chen, Wu-Fu
    Yen, Pao-Sheng
    Harnod, Tomor
    Chiou, Tsung-Lang
    Chang, Yuh-Lin
    Su, Chain-Fa
    Lin, Shinn-Zong
    Chen, Shin-Yuan
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2008, 15 (11) : 1240 - 1245
  • [13] Effects of ionizing radiation on the mechanical properties of human bone
    Currey, JD
    Foreman, J
    Laketic, I
    Mitchell, J
    Pegg, DE
    Reilly, GC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) : 111 - 117
  • [14] Bone growth enhancement in vivo on press-fit titanium alloy implants with acid etched microtexture
    Daugaard, Henrik
    Elmengaard, Brian
    Bechtold, Joan E.
    Soballe, Kjeld
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 87A (02) : 434 - 440
  • [15] Osteocel Plus Cellular Allograft in Anterior Cervical Discectomy and Fusion Evaluation of Clinical and Radiographic Outcomes From a Prospective Multicenter Study
    Eastlack, Robert K.
    Garfi, Steven R.
    Brown, Christopher R.
    Meyer, S. Craig
    [J]. SPINE, 2014, 39 (22) : E1331 - E1337
  • [16] Single level cervical fusion by an anterior approach using autologous bone graft influences the adjacent levels degenerative changes: clinical and radiographic results at 10-year minimum follow-up
    Faldini, C.
    Miscione, M. T.
    Acri, F.
    Leonetti, D.
    Nanni, M.
    Chehrassan, M.
    Giannini, S.
    [J]. EUROPEAN SPINE JOURNAL, 2012, 21 : S90 - S93
  • [17] Single-level anterior cervical discectomy and interbody fusion using PEEK anatomical cervical cage and allograft bone
    Faldini C.
    Chehrassan M.
    Miscione M.T.
    Acri F.
    D'Amato M.
    Pungetti C.
    Luciani D.
    Giannini S.
    [J]. Journal of Orthopaedics and Traumatology, 2011, 12 (4) : 201 - 205
  • [18] Subsidence of stand-alone cervical cages in anterior interbody fusion: warning
    Gercek, E
    Arlet, V
    Delisle, J
    Marchesi, D
    [J]. EUROPEAN SPINE JOURNAL, 2003, 12 (05) : 513 - 516
  • [19] Radiologic Assessment of Subsidence in Stand-Alone Cervical Polyetheretherketone (PEEK) Cage
    Ha, Sung-Kon
    Park, Jung-Yul
    Kim, Se-Hoon
    Lim, Dong-Jun
    Kim, Sang-Dae
    Lee, Sang-Kook
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2008, 44 (06) : 370 - 374
  • [20] The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties
    Han, Cheol-Min
    Lee, Eun-Jung
    Kim, Hyoun-Ee
    Koh, Young-Hag
    Kim, Keung N.
    Ha, Yoon
    Kuh, Sung-Uk
    [J]. BIOMATERIALS, 2010, 31 (13) : 3465 - 3470