PTV-based IMPT optimization incorporating planning risk volumes vs robust optimization

被引:72
作者
Liu, Wei [1 ]
Frank, Steven J. [2 ]
Li, Xiaoqiang [1 ]
Li, Yupeng [3 ]
Zhu, Ron. X. [1 ]
Mohan, Radhe [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Varian Med Syst Inc, Palo Alto, CA 94304 USA
基金
美国国家卫生研究院;
关键词
robust optimization; IMPT; planning risk volume; robustness evaluation; MODULATED PROTON THERAPY; TREATMENT UNCERTAINTIES; RANGE UNCERTAINTIES; SENSITIVITY; CANCER; TUMORS; PLANS; RADIOTHERAPY; DELIVERY; PHOTON;
D O I
10.1118/1.4774363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Robust optimization leads to intensity-modulated proton therapy (IMPT) plans that are less sensitive to uncertainties and superior in terms of organs-at-risk (OARs) sparing, target dose coverage, and homogeneity compared to planning target volume (PTV)-based optimized plans. Robust optimization incorporates setup and range uncertainties, which implicitly adds margins to both targets and OARs and is also able to compensate for perturbations in dose distributions within targets and OARs caused by uncertainties. In contrast, the traditional PTV-based optimization considers only setup uncertainties and adds a margin only to targets but no margins to the OARs. It also ignores range uncertainty. The purpose of this work is to determine if robustly optimized plans are superior to PTV-based plans simply because the latter do not assign margins to OARs during optimization. Methods: The authors retrospectively selected from their institutional database five patients with head and neck (H&N) cancer and one with prostate cancer for this analysis. Using their original images and prescriptions, the authors created new IMPT plans using three methods: PTV-based optimization, optimization based on the PTV and planning risk volumes (PRVs) (i.e., "PTV+PRV-based optimization"), and robust optimization using the "worst-case" dose distribution. The PRVs were generated by uniformly expanding OARs by 3 mm for the H&N cases and 5 mm for the prostate case. The dose-volume histograms (DVHs) from the worst-case dose distributions were used to assess and compare plan quality. Families of DVHs for each uncertainty for all structures of interest were plotted along with the nominal DVHs. The width of the "bands" of DVHs was used to quantify the plan sensitivity to uncertainty. Results: Compared with conventional PTV-based and PTV+PRV-based planning, robust optimization led to a smaller bandwidth for the targets in the face of uncertainties {clinical target volume [CTV] bandwidth: 0.59 [robust], 3.53 [PTV+PRV], and 3.53 [PTV] Gy (RBE)}. It also resulted in higher doses to 95% of the CTV {D-95%:60.8 [robust] vs 59.3 [PTV+PRV] vs 59.6 [PTV] Gy (RBE)}, smaller D-5% (doses to 5% of the CTV) minus D-95% {D-5% - D-95%: 13.2 [robust] vs 17.5 [PTV+PRV] vs 17.2 [PTV] Gy (RBE)}. At the same time, the robust optimization method irradiated OARs less {maximum dose to 1 cm(3) of the brainstem: 48.3 [robust] vs 48.8 [PTV+PRV] vs 51.2 [PTV] Gy (RBE); mean dose to the oral cavity: 22.3 [robust] vs 22.9 [PTV+PRV] vs 26.1 [PTV] Gy (RBE); maximum dose to 1% of the normal brain: 66.0 [robust] vs 68.0 [PTV+PRV] vs 69.3 [PTV] Gy (RBE)}. Conclusions: For H&N cases studied, OAR sparing in PTV+PRV-based optimization was inferior compared to robust optimization but was superior compared to PTV-based optimization; however, target dose robustness and homogeneity were comparable in the PTV+PRV-based and PTV-based optimizations. The same pattern held for the prostate case. The authors' data suggest that the superiority of robust optimization is not due simply to its inclusion of margins for OARs, but that this is due mainly to the ability of robust optimization to compensate for perturbations in dose distributions within target volumes and normal tissues caused by uncertainties. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4774363]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Technical Note: 4D robust optimization in small spot intensity-modulated proton therapy (IMPT) for distal esophageal carcinoma
    Feng, Hongying
    Shan, Jie
    Ashman, Jonathan B.
    Rule, William G.
    Bhangoo, Ronik S.
    Yu, Nathan Y.
    Chiang, Jennifer
    Fatyga, Mirek
    Wong, William W.
    Schild, Steven E.
    Sio, Terence T.
    Liu, Wei
    MEDICAL PHYSICS, 2021, 48 (08) : 4636 - 4647
  • [22] Clinical implementation in proton therapy of multi-field optimization by a hybrid method combining conventional PTV with robust optimization
    Tommasino, Francesco
    Widesott, Lamberto
    Fracchiolla, Francesco
    Lorentini, Stefano
    Righetto, Roberto
    Algranati, Carlo
    Scifoni, Emanuele
    Dionisi, Francesco
    Scartoni, Daniele
    Amelio, Dante
    Cianchetti, Marco
    Schwarz, Marco
    Amichetti, Maurizio
    Farace, Paolo
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04)
  • [23] Robust optimization vs. stochastic programming incorporating risk measures for unit commitment with uncertain variable renewable generation
    Narges Kazemzadeh
    Sarah M. Ryan
    Mahdi Hamzeei
    Energy Systems, 2019, 10 : 517 - 541
  • [24] Robust optimization vs. stochastic programming incorporating risk measures for unit commitment with uncertain variable renewable generation
    Kazemzadeh, Narges
    Ryan, Sarah M.
    Hamzeei, Mahdi
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2019, 10 (03): : 517 - 541
  • [25] Incorporating local uncertainty management into distribution system planning: An adaptive robust optimization approach
    Zhu, Junpeng
    Huang, Yong
    Lu, Shuai
    Shen, Mengya
    Yuan, Yue
    APPLIED ENERGY, 2024, 363
  • [26] Distributed and scalable optimization for robust proton treatment planning
    Fu, Anqi
    Taasti, Vicki T.
    Zarepisheh, Masoud
    MEDICAL PHYSICS, 2023, 50 (01) : 633 - 642
  • [27] Light Pareto robust optimization for IMRT treatment planning
    Ripsman, Danielle A.
    Rahimi, Fahimeh
    Abouee-Mehrizi, Hossein
    Mahmoudzadeh, Houra
    MEDICAL PHYSICS, 2023, 50 (05) : 2637 - 2648
  • [28] Potential pitfalls of the PTV concept in dose-to-medium planning optimization
    Sterpin, E.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (09): : 1103 - 1110
  • [29] Robust Optimization for Strategic Energy Planning
    Moret, Stefano
    Bierlaire, Michel
    Marechal, Francois
    INFORMATICA, 2016, 27 (03) : 625 - 648
  • [30] Robust Optimization for Transmission Expansion Planning: Minimax Cost vs. Minimax Regret
    Chen, Bokan
    Wang, Jianhui
    Wang, Lizhi
    He, Yanyi
    Wang, Zhaoyu
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (06) : 3069 - 3077