Raise the Bar and Lower the Dose: Current and Future Strategies for Radiation Dose Reduction in Head and Neck Imaging

被引:19
作者
Ibrahim, M. [1 ]
Parmar, H. [1 ]
Christodoulou, E. [1 ]
Mukherji, S. [1 ]
机构
[1] Univ Michigan Hlth Syst, Ann Arbor, MI 48109 USA
关键词
MULTIDETECTOR CT; QUALITY; STANDARD; ANGIOGRAPHY; MODULATION; PITCH;
D O I
10.3174/ajnr.A3473
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Technologic advances in CT have generated a dramatic increase in the number of CT studies, with a resultant increase in the radiation dose related to CT scanning. Such increase in radiation dose is becoming a concern for the radiology community, especially with increasing public awareness of the dose burden related to examinations. To cope with the increase in CT-related radiation exposure, it is becoming necessary to optimize CT imaging protocols and apply radiation dose reduction techniques to ensure the best imaging with the lowest radiation dose.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 29 条
[1]   CT dosimetry: comparison of measurement techniques and devices [J].
Bauhs, John A. ;
Vrieze, Thomas J. ;
Primak, Andrew N. ;
Bruesewitz, Michael R. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2008, 28 (01) :245-253
[2]   Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation [J].
Christner, Jodie A. ;
Zavaletta, Vanessa A. ;
Eusemann, Christian D. ;
Walz-Flannigan, Alisa I. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W49-W55
[3]  
Feigal David W Jr, 2002, Int J Trauma Nurs, V8, P1, DOI 10.1067/mtn.2002.121511
[4]   Organ-Based Dose Current Modulation and Thyroid Shields: Techniques of Radiation Dose Reduction for Neck CT [J].
Hoang, Jenny K. ;
Yoshizumi, Terry T. ;
Choudhury, Kingshuk Roy ;
Nguyen, Giao B. ;
Toncheva, Greta ;
Gafton, Andreia R. ;
Eastwood, James D. ;
Lowry, Carolyn ;
Hurwitz, Lynne M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) :1132-1138
[5]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[6]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[7]   Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Sato, Jiro ;
Akai, Hiroyuki ;
Yasaka, Koichiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
EUROPEAN RADIOLOGY, 2012, 22 (08) :1613-1623
[8]   Lowering the Dose in Head CT Using Adaptive Statistical Iterative Reconstruction [J].
Kilic, K. ;
Erbas, G. ;
Guryildirim, M. ;
Arac, M. ;
Ilgit, E. ;
Coskun, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (09) :1578-1582
[9]   Radiation dose modulation techniques in the multidetector CT era: From basics to practice [J].
Lee, Chang Hyun ;
Goo, Jin Mo ;
Lee, Hyun Ju ;
Ye, Sung-Joon ;
Park, Chang Min ;
Chun, Eun Ju ;
Im, Jung-Gi .
RADIOGRAPHICS, 2008, 28 (05) :1451-1459
[10]   Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography [J].
Lee, E. J. ;
Lee, S. K. ;
Agid, R. ;
Howard, P. ;
Bae, J. M. ;
terBrugge, K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (09) :1754-1759