Lesion Index Titration Using Contact-Force Technology Enables Safe and Effective Radiofrequency Lesion Creation at the Root of the Aorta and Pulmonary Artery

被引:7
作者
Manuel Alfonso-Almazan, Jose [1 ]
Quintanilla, Jorge G. [1 ,2 ,3 ]
Jesus Garcia-Torrent, Maria [4 ]
Laguna-Castro, Santiago [1 ]
Rodriguez-Bobada, Cruz [5 ]
Gonzalez, Pablo [5 ]
Jose Gonzalez-Ferrer, Juan [2 ,3 ]
Salinas, Pablo [2 ]
Canadas-Godoy, Victoria [2 ,3 ]
Moreno, Javier [3 ,6 ]
Borrego-Bernabe, Luis [2 ]
Perez-Castellano, Nicasio [2 ,3 ]
Jalife, Jose [1 ,3 ,7 ]
Perez-Villacastin, Julian [2 ,3 ,4 ]
Filgueiras-Rama, David [1 ,3 ]
机构
[1] Carlos III CNIC, Ctr Nacl Invest Cardiovasc, Myocardial Pathophysiol Area, Melchor Fernandez Almagro 3, Madrid 28029, Spain
[2] Hosp Clin San Carlos IdISSC, Inst Invest Sanitaria, Dept Cardiol, Cardiovasc Inst, Madrid, Spain
[3] CIBER Enfermedades Cardiovasc, Madrid, Spain
[4] Fdn Interhosp Invest Cardiovasc FIG, Madrid, Spain
[5] Hosp Clin San Carlos IdISSC, Inst Invest Sanitaria, Expt Med & Surg Unit, Madrid, Spain
[6] Hosp Univ Ramon & Cajal, Dept Cardiol, Madrid, Spain
[7] Univ Michigan, Dept Internal Med, Cardiovasc Res Ctr, Ctr Arrhythmia Res, Ann Arbor, MI 48109 USA
关键词
aorta; catheter ablation; contact force; elastin; pulmonary artery; CATHETER ABLATION; CUSP; ANATOMY;
D O I
10.1161/CIRCEP.118.007080
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Ablation of some myocardial substrates requires catheter-based radiofrequency delivery at the root of a great artery. We studied the safety and efficacy parameters associated with catheter-based radiofrequency delivery at the root of the aorta and pulmonary artery. METHODS: Thirty-six pigs underwent in-vivo catheter-based ablation under continuous contact-force and lesion index (power, contact-force, and time) monitoring during 60-s radiofrequency delivery with an open-irrigated tip catheter. Twenty-eight animals were allocated to groups receiving 40 W (n=9), 50 W (n=10), or 60 W (n=9) radiofrequency energy, and acute (n=22) and chronic (n=6) arterial wall damage was quantified by multiphoton microscopy in ex vivo samples. Adjacent myocardial lesions were quantified in parallel samples. The remaining 8 pigs were used to validate safety and efficacy parameters. RESULTS: Acute collagen and elastin alterations were significantly associated with radiofrequency power, although chronic assessment revealed vascular wall recovery in lesions without steam pop. The main parameters associated with steam pops were median peak temperature >42 degrees C and impedance falls >23 ohms. Unlike other parameters, lesion index values of 9.1 units (interquartile range, 8.7-9.8) were associated with the presence of adjacent myocardial lesions in both univariate (P=0.03) and multivariate analyses (P=0.049; odds ratio, 1.99; 95% CI, 1.02-3.98). In the validation group, lesion index values using 40 W over a range of contact-forces correlated with the size of radiofrequency lesions (R-2=0.57; P=0.03), with no angiographic or histopathologic signs of coronary artery damage. CONCLUSIONS: Lesion index values obtained during 40 W radiofrequency applications reliably monitor safe and effective lesion creation at the root of the great arteries.
引用
收藏
页数:14
相关论文
共 23 条
[1]   EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias [J].
Aliot, Etienne M. ;
Stevenson, William G. ;
Ma Almendral-Garrote, Jesus ;
Bogun, Frank ;
Calkins, C. Hugh ;
Delacretaz, Etienne ;
Della Bella, Paolo ;
Hindricks, Gerhard ;
Jais, Pierre ;
Josephson, Mark E. ;
Kautzner, Josef ;
Kay, G. Neal ;
Kuck, Karl-Heinz ;
Lerman, Bruce B. ;
Marchlinski, Francis ;
Reddy, Vivek ;
Schalij, Martin-Jan ;
Schilling, Richard ;
Soejima, Kyoko ;
Wilber, David .
HEART RHYTHM, 2009, 6 (06) :886-933
[2]   Application of 2,3,5-triphenyltetrazolium chloride staining to evaluate injury volume after controlled cortical impact brain injury: Role of brain edema in evolution of injury volume [J].
Baskaya, MK ;
Dogan, A ;
Temiz, C ;
Dempsey, RJ .
JOURNAL OF NEUROTRAUMA, 2000, 17 (01) :93-99
[3]   Ablation of focal atrial tachycardia from the non-coronary aortic cusp: case series and review of the literature [J].
Beukema, Rypko J. ;
Smit, Jaap Jan J. ;
Adiyaman, Ahmet ;
Van Casteren, Lieve ;
Delnoy, Peter Paul H. M. ;
Misier, Anand R. Ramdat ;
Elvan, Arif .
EUROPACE, 2015, 17 (06) :953-961
[4]  
Calzolari Vittorio, 2017, JACC Clin Electrophysiol, V3, P1126, DOI 10.1016/j.jacep.2017.08.016
[5]   Anatomy of the pig heart: comparisons with normal human cardiac structure [J].
Crick, SJ ;
Sheppard, MN ;
Ho, SY ;
Gepstein, L ;
Anderson, RH .
JOURNAL OF ANATOMY, 1998, 193 :105-119
[6]   What is the most appropriate energy source for aortic cusp ablation? A comparison of standard RF, cooled-tip RF and cryothermal ablation [J].
d'Avila, Andre ;
Thiagalingam, Aravinda ;
Holmvang, Godtfred ;
Houghtaling, Christopher ;
Ruskin, Jeremy N. ;
Reddy, Vivek Y. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (01) :31-38
[7]  
Fontenla A, 2017, REV ESP CARDIOL, V70, P971, DOI [10.1016/j.rec.2017.07.012, 10.1016/j.recesp.2017.07.023]
[8]   Long-term Outcomes of Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta-analysis [J].
Ganesan, Anand N. ;
Shipp, Nicholas J. ;
Brooks, Anthony G. ;
Kuklik, Pawel ;
Lau, Dennis H. ;
Lim, Han S. ;
Sullivan, Thomas ;
Roberts-Thomson, Kurt C. ;
Sanders, Prashanthan .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2013, 2 (02) :e004549
[9]   Effects of Open-Irrigated Radiofrequency Ablation Catheter Design on Lesion Formation and Complications: In Vitro Comparison of 6 Different Devices [J].
Guerra, Jose M. ;
Jorge, Esther ;
Raga, Silvia ;
Galvez-Monton, Carolina ;
Alonso-Martin, Concepcion ;
Rodriguez-Font, Enrique ;
Cinca, Juan ;
Vinolas, Xavier .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (10) :1157-1162
[10]   Necrotic pyknosis is a morphologically and biochemically distinct event from apoptotic pyknosis [J].
Hou, Lin ;
Liu, Kai ;
Li, Yuhong ;
Ma, Shuang ;
Ji, Xunming ;
Liu, Lei .
JOURNAL OF CELL SCIENCE, 2016, 129 (16) :3084-3090