Coupled simulation method by using MCRT and FVM techniques for performance analysis of a parabolic trough solar collector

被引:10
作者
Agagna, Belkacem [1 ]
Smaili, Arezki [1 ]
Falcoz, Quentin [2 ]
机构
[1] Ecole Natl Polytech, Mech Engn & Dev Lab, BP 182 El Harrach, Algiers 16200, Algeria
[2] Proc Mat & Solar Energy Lab, 7 Rue Four Solaire, F-66120 Odeillo Font Romeu, France
来源
POWER AND ENERGY SYSTEMS ENGINEERING, (CPESE 2017) | 2017年 / 141卷
关键词
Parabolic trough solar collector; Mont Carlo Ray Tracing method; Heat flux distribution; Finite Volume method; tracking error; NUMERICAL-SIMULATION;
D O I
10.1016/j.egypro.2017.11.007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Concentrating solar power (CSP) represents a powerful, clean, endless, and reliable source of energy. Which, the parabolic trough collector (PTC) system was the first CSP technology to date, thus it is the most developed and most commonly replicated system. The optical analysis of a solar concentrator represents a major interest to evaluate the performances of the system. When, the heat flux distribution around the receiver tube is the aim parameter effected by this analysis. With sun's movement from east to west, collector continuously turns about an axis, tracking sun's radiation and maintaining the focus of collector on receiver tube. The present paper is focused to study the effects of the tracking mechanism on the performance of the PTC taking into account the non-uniformity of solar flux. Firstly, a 3D optical model based on the Monte Carlo Ray Tracing method (MCRT) written in MATLAB software has been developed. Then, the local concentration ratio (LCR) has been calculated to validate the MCRT method. In order to study the effects of the tracking errors, the developed model has been applied to determine the circumferential flux distribution around the absorber tube and the resulting optical efficiency of LS2 collector of Solar Thermal Electric Generation Systems (SEGS). In the second part, the results of the MCRT code has been coupled with FVM method using ANSYS software to analyze the heat flux distribution on the absorber tube under some tracking error values. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 15 条
[1]  
[Anonymous], 2011, SIMPLIFIED METHODOLO
[2]   A new modelling method and unified code with MCRT for concentrating solar collectors and its applications [J].
Cheng, Z. D. ;
He, Y. L. ;
Cui, F. Q. .
APPLIED ENERGY, 2013, 101 :686-698
[3]   Numerical simulation of a parabolic trough solar collector with nonuniform solar flux conditions by coupling FVM and MCRT method [J].
Cheng, Z. D. ;
He, Y. L. ;
Cui, F. Q. ;
Xu, R. J. ;
Tao, Y. B. .
SOLAR ENERGY, 2012, 86 (06) :1770-1784
[4]  
Cheng Z.D., 2010, HEAT MASS TRANSFER, V37, P782
[5]  
Dudley VE, 1994, TEST RESULTS SEGS LS
[6]  
Duffie J.A., 1994, Solar Engineering of Thermal Processes
[7]  
Forristall R., 2003, TECHNICAL REPORT
[8]   Numerical simulation of parabolic trough solar collector: Improvement using counter flow concentric circular heat exchangers [J].
Garcia-Valladares, O. ;
Velazquez, N. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (3-4) :597-609
[9]   Heat transfer analysis and numerical simulation of a parabolic trough solar collector [J].
Hachicha, A. A. ;
Rodriguez, I. ;
Capdevila, R. ;
Oliva, A. .
APPLIED ENERGY, 2013, 111 :581-592
[10]   A MCRT and FVM coupled simulation method for energy conversion process in parabolic trough solar collector [J].
He, Ya-Ling ;
Xiao, Jie ;
Cheng, Ze-Dong ;
Tao, Yu-Bing .
RENEWABLE ENERGY, 2011, 36 (03) :976-985