CT Angiography Evaluation of Unusual Transorbital Penetrating Injury: A Toothbrush

被引:9
作者
Atay, Musa [1 ]
Alkan, Alpay [1 ]
Hanimoglu, Hakan [1 ]
Sharifov, Rasul [1 ]
Kilicarslan, Rukiye [1 ]
Aralasmak, Ayse [1 ]
机构
[1] Bezmialem Vakif Univ, Sch Med, Dept Radiol, Istanbul, Turkey
关键词
CT angiography; orbital foreign body; orbital trauma; toothbrush; ORBITAL TRAUMA;
D O I
10.1111/jon.12003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Orbital penetrating injuries may cause significant harm to optic nerves and eyeball as well as to the brain and cerebral vasculature. Defining surrounding neurovascular structures by CT angiography (CTA) is important for surgical removal. We present an uncommon case of a 3-year-old child with a penetrating orbital injury caused by a toothbrush. To the best of our knowledge, there is no report orbital injury with a toothbrush so far.
引用
收藏
页码:314 / 316
页数:3
相关论文
共 50 条
  • [31] CT angiography for evaluation of cerebral vasospasm following acute subarachnoid haemorrhage
    Jai Jai Shiva Shankar
    Irene Y. L. Tan
    Timo Krings
    Karel Terbrugge
    Ronit Agid
    Neuroradiology, 2012, 54 : 197 - 203
  • [32] Multislice CT angiography in the evaluation of great saphenous vein for suitability as arterial bypass. Are CT angiography data sufficient for planning autologous reconstruction?
    Gudz, I. M.
    Ivasyuk, U. D.
    Yakibtschuk, O. I.
    Kmetyuk, V. M.
    Dezyk, O. Z.
    Tkatschuk, O. L.
    Balzer, K.
    Gudz, O. I.
    GEFASSCHIRURGIE, 2015, 20 (08): : 576 - 580
  • [33] CT Angiography Source-Images and CT Perfusion: Are They Complementary Tools for Ischemic Stroke Evaluation? Response to: Reliability of CT Perfusion in the Evaluation of Ischaemic Penumbra
    Morelli, Nicola
    Rota, Eugenia
    Immovilli, Paolo
    Iafelice, Ilaria
    Michieletti, Emanuele
    Guidetti, Donata
    Morelli, John
    NEURORADIOLOGY JOURNAL, 2014, 27 (03) : 365 - 367
  • [34] Accessory left upper lobe fissures containing vascular contents: Unusual entities depicted on CT angiography
    Bhatia, Harsimran
    Aswal, Chandra Shekhar Singh
    Sharma, Arun
    Singhal, Manphool
    PEDIATRIC PULMONOLOGY, 2023, 58 (12) : 3609 - 3611
  • [35] Screening and detection of blunt vertebral artery injury in patients with upper cervical fractures: The role of cervical CT and CT angiography
    Payabvash, Seyedmehdi
    McKinney, Alexander M.
    McKinney, Zeke J.
    Palmer, Christopher S.
    Truwit, Charles L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (03) : 571 - 577
  • [36] Idiopathic myointimal hyperplasia of mesenteric veins: radiological evaluation using CT angiography
    Morimura, Fumio
    Edo, Hiromi
    Niwa, Takafumi
    Sugiura, Hiroaki
    Suyama, Yohsuke
    Okazaki, Soya
    Narimatsu, Kazuyuki
    Ohno, Hiroki
    Okamoto, Koichi
    Ueno, Hideki
    Yoshimatsu, Shinya
    Miyai, Kosuke
    Hamamoto, Kohei
    Shinmoto, Hiroshi
    BJR CASE REPORTS, 2023, 10 (01):
  • [37] Pulmonary vein anatomy variants as a biomarker of atrial fibrillation - CT angiography evaluation
    Skowerski, M.
    Wozniak-Skowerska, I.
    Hoffmann, A.
    Nowak, S.
    Skowerski, T.
    Sosnowski, M.
    Wnuk-Wojnar, A. M.
    Mizia-Stec, K.
    BMC CARDIOVASCULAR DISORDERS, 2018, 18
  • [38] Multi-slice CT angiography in evaluation of extracranial-intracranial bypass
    Teksam, M
    McKinney, A
    Truwit, CL
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 52 (03) : 217 - 220
  • [39] Pulmonary vein anatomy variants as a biomarker of atrial fibrillation – CT angiography evaluation
    M. Skowerski
    I. Wozniak-Skowerska
    A. Hoffmann
    S. Nowak
    T. Skowerski
    M. Sosnowski
    A. M. Wnuk-Wojnar
    K. Mizia-Stec
    BMC Cardiovascular Disorders, 18
  • [40] Next generation coronary CT angiography: in vitro evaluation of 27 coronary stents
    Gassenmaier, Tobias
    Petri, Nils
    Allmendinger, Thomas
    Flohr, Thomas
    Maintz, David
    Voelker, Wolfram
    Bley, Thorsten A.
    EUROPEAN RADIOLOGY, 2014, 24 (11) : 2953 - 2961