Safety of the LMA®Gastro™ for Endoscopic Retrograde Cholangiopancreatography

被引:18
作者
Hagan, Katherine B. [1 ]
Carlson, Richard [1 ]
Arnold, Benjamin [1 ]
Nguyen, Linh [1 ]
Lee, Jeffrey [2 ]
Weston, Brian [2 ]
Hernandez, Mike [3 ]
Feng, Lei [3 ]
Syed, Tariq [1 ]
Hagberg, Carin A. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Anesthesiol & Perioperat Med, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Gastroenterol Hepatol & Nutr, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
关键词
LARYNGEAL MASK AIRWAY; UPPER GASTROINTESTINAL ENDOSCOPY; GENERAL-ANESTHESIA; OBESE-PATIENTS; DEEP SEDATION; NASAL CANNULA; HIGH-FLOW; COLONOSCOPY; RISK; INTUBATION;
D O I
10.1213/ANE.0000000000005183
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) patients typically receive either tubeless anesthesia or general endotracheal anesthesia (GETA). Patients receiving propofol-based total intravenous anesthesia (TIVA) are at higher risk of sedation-related adverse events (SRAEs) than patients receiving GETA, primarily due to the need for additional airway maneuvers. The increasing use of non-operating room (OR) anesthesia and the perception of a higher incidence of adverse outcomes in non-OR areas has led to the development of devices to improve safety while maintaining efficiency. The purpose of this study was to evaluate if the LMA(R)Gastro (TM) could be used as a safe alternative to tubeless anesthesia for successfully completing ERCPs. METHODS: Eligible subjects were identified within the patient population at MD Anderson Cancer Center. Inclusion criteria consisted of adult patients (>= 18 years old) scheduled for elective ERCP with TIVA. This was a prospective observational study in which the following data were collected: number of attempts and time to successful supraglottic airway (SGA) placement, vital signs, peripheral oxygen saturation (Spo(2)), median end-tidal CO2, practitioner satisfaction, and any complications. RESULTS: A total of 30 patients were included in this study. The overall rate of successful SGA placement within 3 attempts was 96.7% (95% confidence interval [CI], 82.8-99.9) or 29/30. The rate of successful ERCP with SGA placement within 3 attempts was 93.3% (95% CI, 77.9-99.2) or 28/30. Both the gastroenterologist and anesthesiologist reported satisfaction with the device in 90% of the cases (in 66.7% of the cases both anesthesiologist and gastroenterologist scored the device a 7/7 for satisfaction). Patients maintained an Spo(2)of 95%-100% from induction to discharge, with the exception of 1 patient who had an Spo(2)of 93%. The median end-tidal CO(2)during the procedure for all patients was 35 mm Hg. Observed aspiration did not occur in any patient. Symptoms of hoarseness (13.3%), mouth soreness (6.7%), sore throat (6.6%), and minor bleeding/cuts/redness/change in taste to the tongue (3.3%) were determined through patient questioning before postanesthesia care unit (PACU) discharge. CONCLUSIONS: Our study suggests that the LMA Gastro might be a safe alternative for ERCP procedures. There was a high level of practitioner satisfaction. Only minor complications, such as hoarseness, mouth or throat soreness, or minor trauma to the tongue were experienced by patients. Similar incidences of complications may occur with GETA and tubeless anesthesia. The procedure was well tolerated by all patients; all patients maintained adequate oxygenation and required only minimal blood pressure support.
引用
收藏
页码:1566 / 1572
页数:7
相关论文
共 24 条
[1]   Comparison of the laryngeal mask airway Supreme and laryngeal mask airway Classic in adults [J].
Ali, Achmet ;
Canturk, Selcuk ;
Turkmen, Aygen ;
Turgut, Namigar ;
Altan, Aysel .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (12) :1010-1014
[2]   Comparison of a simplified nasal continuous positive airways pressure device with nasal cannula in obese patients undergoing colonoscopy during deep sedation A randomised clinical trial [J].
Bai, Yiping ;
Xu, Zeping ;
Chandrashekar, Meera ;
St Jacques, Paul J. ;
Liang, Yafen ;
Jiang, Yandong ;
Kla, Koffi .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (09) :633-640
[3]   Effect of a Strategy of a Supraglottic Airway Device vs Tracheal Intubation During Out-of-Hospital Cardiac Arrest on Functional Outcome The AIRWAYS-2 Randomized Clinical Trial [J].
Benger, Jonathan R. ;
Kirby, Kim ;
Black, Sarah ;
Brett, Stephen J. ;
Clout, Madeleine ;
Lazaroo, Michelle J. ;
Nolan, Jerry P. ;
Reeves, Barnaby C. ;
Robinson, Maria ;
Scott, Lauren J. ;
Smartt, Helena ;
South, Adrian ;
Stokes, Elizabeth A. ;
Taylor, Jodi ;
Thomas, Matthew ;
Voss, Sarah ;
Wordsworth, Sarah ;
Rogers, Chris A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 320 (08) :779-791
[4]   Injury and liability associated with monitored anesthesia care - A closed claims analysis [J].
Bhananker, SM ;
Posner, KL ;
Cheney, FW ;
Caplan, RA ;
Lee, LA ;
Domino, KB .
ANESTHESIOLOGY, 2006, 104 (02) :228-234
[5]   Stricter national standards are required for credentialing of endoscopic-retrograde-cholangiopancreatography in the United States [J].
Cappell, Mitchell S. ;
Friedel, David M. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2019, 25 (27) :3468-3483
[6]   Interventional Procedures Outside of the Operating Room: Results From the National Anesthesia Clinical Outcomes Registry [J].
Chang, Beverly ;
Kaye, Alan D. ;
Diaz, James H. ;
Westlake, Benjamin ;
Dutton, Richard P. ;
Urman, Richard D. .
JOURNAL OF PATIENT SAFETY, 2018, 14 (01) :9-16
[7]  
Erdivanli B, 2018, REV BRAS ANESTESIOL, V68, P499, DOI [10.1016/j.bjan.2018.04.003, 10.1016/j.bjane.2018.04.008]
[8]  
Goudra B, 2017, CLIN ENDOSC, V50, P161, DOI 10.5946/ce.2016.019
[9]   Propofol and non-propofol based sedation for outpatient colonoscopy-prospective comparison of depth of sedation using an EEG based SEDLine monitor [J].
Goudra, Basavana ;
Singh, Preet Mohinder ;
Gouda, Gowri ;
Borle, Anuradha ;
Carlin, Augustus ;
Yadwad, Avantika .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (05) :551-557
[10]  
Gross JB, 2002, ANESTHESIOLOGY, V96, P1004