Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner

被引:91
作者
Du, Jiang [1 ]
Ma, Guolin [1 ,2 ]
Li, Shihong [1 ,6 ]
Carl, Michael [3 ]
Szeverenyi, Nikolaus M. [1 ]
VandenBerg, Scott [4 ]
Corey-Bloom, Jody [5 ]
Bydder, Graeme M. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[2] China Japan Friendship Hosp, Dept Radiol, Beijing, Peoples R China
[3] GE Healthcare, Global Appl Sci Lab, San Diego, CA USA
[4] Univ Calif San Diego, Dept Pathol, San Diego, CA 92103 USA
[5] Univ Calif San Diego, Dept Neurosci, San Diego, CA 92103 USA
[6] Fudan Univ, Huadong Hosp, Dept Radiol, Shanghai 200433, Peoples R China
关键词
Ultrashort echo time; Adiabatic IR; Ultrashort T2; White matter; T2*; Proton density; RELAXATION-TIMES; MYELIN; WATER; MRI; T-2; QUANTIFICATION; CONTRAST; NERVE;
D O I
10.1016/j.neuroimage.2013.10.053
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
White matter of the brain contains a majority of long T2 components as well as a minority of short T2 components. These are not detectable using clinical magnetic resonance imaging (MRI) sequences with conventional echo times (TEs). In this study we used ultrashort echo time (UTE) sequences to investigate the ultrashort 12 components in white matter of the brain and quantify their T2*s and relative proton densities (RPDs) (relative to water with a proton density of 100%) using a clinical whole body 31 scanner. An adiabatic inversion recovery prepared dual echo UTE (IR-dUTE) sequence was used for morphological imaging of the ultrashort T2 components in white matter. IR-dUTE acquisitions at a constant TR of 1000 ms and a series of TIs were performed to determine the optimal TI which corresponded to the minimum signal to noise ratio (SNR) in white matter of the brain on the second echo image. T2's -Orthe ultraiErre T2 corriPonents were ifuantified u-slhg exponential decay fitting of the IR-dUTE signal at a series of TEs. RPD was quantified by comparing IR-dUTE signal of the ultrashort T2 components with that of a rubber phantom. Nine healthy volunteers were studied. The IRdUTE sequence provided excellent image contrast for the ultrashort T2 components in white matter of the brain with a mean signal to noise ratio of 18.7 +/- 3.7 and a contrast to noise ratio of 14.6 +/- 2.4 between the ultrashort T2 white matter and gray matter in a 4.4 min scan time with a nominal voxel size of 1.25 x 125 x 5.0 mm(3). On average a T2* value of 0.42 +/- 0.08 ms and a RPD of 4.05 0.88% were demonstrated for the ultrashort T2 components in white matter of the brain of healthy volunteers at 31. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:32 / 41
页数:10
相关论文
共 37 条
[1]   Ultrashort echo time (UTE) imaging with bi-component analysis: Bound and free water evaluation of bovine cortical bone subject to sequential drying [J].
Biswas, Reni ;
Bae, Won ;
Diaz, Eric ;
Masuda, Koichi ;
Chung, Christine B. ;
Bydder, Graeme M. ;
Du, Jiang .
BONE, 2012, 50 (03) :749-755
[2]   T1 AND T2 MEASUREMENTS ON A 1.5-T COMMERCIAL MR IMAGER [J].
BREGER, RK ;
RIMM, AA ;
FISCHER, ME ;
PAPKE, RA ;
HAUGHTON, VM .
RADIOLOGY, 1989, 171 (01) :273-276
[3]   Compartmental study of T1 and T2 in rat brain and trigeminal nerve in vivo [J].
Does, MD ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :274-283
[4]   Two-dimensional ultrashort echo time imaging using a spiral trajectory [J].
Du, Jiang ;
Bydder, Mark ;
Takahashi, Atsushi M. ;
Chung, Christine B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :304-312
[5]   Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone [J].
Du, Jiang ;
Hamilton, Gavin ;
Takahashi, Atsushi ;
Bydder, Mark ;
Chung, Christine B. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :1001-1009
[6]   Short T2 contrast with three-dimensional ultrashort echo time imaging [J].
Du, Jiang ;
Bydder, Mark ;
Takahashi, Atsushi M. ;
Carl, Michael ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IMAGING, 2011, 29 (04) :470-482
[7]   Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone [J].
Du, Jiang ;
Carl, Michael ;
Bydder, Mark ;
Takahashi, Atsushi ;
Chung, Christine B. ;
Bydder, Graeme M. .
JOURNAL OF MAGNETIC RESONANCE, 2010, 207 (02) :304-311
[8]   Ultrashort TE Imaging With Off-Resonance Saturation Contrast (UTE-OSC) [J].
Du, Jiang ;
Takahashi, Atsushi M. ;
Bydder, Mark ;
Chung, Christine B. ;
Bydder, Graeme M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) :527-531
[9]   Fast multislice mapping of the myelin water fraction using multicompartment analysis of T2* decay at 3T:: A preliminary postmortem study [J].
Du, Yiping P. ;
Chu, Renxin ;
Hwang, Dosik ;
Brown, Mark S. ;
Kleinschmidt-DeMasters, Bette K. ;
Singel, Debra ;
Simon, Jack H. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :865-870
[10]  
Ercan E., 2012, P ISMRM 20 ANN M EXH, P4279