A reagent-free tubular biofilm reactor for on-line determination of biochemical oxygen demand

被引:20
作者
Liu, Changyu [1 ]
Zhao, Huijun [2 ]
Gao, Shan [3 ]
Jia, Jianbo [1 ]
Zhao, Limin [3 ]
Yong, Daming [1 ]
Dong, Shaojun [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
[2] Griffith Univ, Ctr Clean Environm & Energy, Nathan, Qld 4222, Australia
[3] Changchun Municipal Environm Protect Bur, Changchun 130022, Peoples R China
基金
澳大利亚研究理事会; 中国国家自然科学基金;
关键词
Tubular biofilm reactor; Biochemical oxygen demand (BOO); Toxicants; Reagent-free system; BOD; BIOSENSOR; FERRICYANIDE; TOXICITY; SYSTEM; CELLS; ASSAY;
D O I
10.1016/j.bios.2013.01.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We reported a reagent-free tubular biofilm reactor (BFR) based analytical system for rapid online biochemical oxygen demand (BUD) determination. The BFR was cultivated using microbial seeds from activated sludge. It only needs tap water to operate and does not require any chemical reagent. The analytical performance of this reagent-free BFR system was found to be equal to or better than the BFR system operated using phosphate buffer saline (PBS) and high purity deionized water. The system can readily achieve a limit of detection of 0.25 mg O-2 L-1, possessing superior reproducibility, and longterm operational and storage stability. More importantly, we confirmed for the first time that the BFR system is capable of tolerating common toxicants found in wastewaters, such as 3,5-dichlorophenol and Zn(II), Cr(VI), Cd(II), Cu(II), Pb(II), Mn(II) and Ni(II), enabling the method to be applied to a wide range of wastewaters. The sloughing and clogging are the important attributes affecting the operational stability, hence, the reliability of most online wastewater monitoring systems, which can be effectively avoided, benefiting from the tubular geometry of the reactor and high flow rate conditions. These advantages, coupled with simplicity in device, convenience in operation and minimal maintenance, make such a reagent-free BFR analytical system promising for practical BUD online determination. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 32 条
[1]  
American Public Health Association American Water Works Association Water Environment Federation, 1997, STAND METH EX WAT WA
[2]   Development of a rapid ferricyanide-mediated assay for biochemical oxygen demand using a mixed microbial consortium [J].
Catterall, K ;
Zhao, HJ ;
Pasco, N ;
John, R .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2584-2590
[3]   Designing an amperometric thick-film microbial BOD sensor [J].
Chan, CY ;
Lehmann, M ;
Chan, KM ;
Chan, PY ;
Chan, CW ;
Gruendig, B ;
Kunze, G ;
Renneberg, R .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (7-8) :343-353
[4]   Improvement of a microbial fuel cell performance as a BOD sensor using respiratory inhibitors [J].
Chang, IS ;
Moon, H ;
Jang, JK ;
Kim, BH .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (09) :1856-1859
[5]   Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor [J].
Chang, IS ;
Jang, JK ;
Gil, GC ;
Kim, M ;
Kim, HJ ;
Cho, BW ;
Kim, BH .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :607-613
[6]   Development of photocatalytic biosensor for the evaluation of biochemical oxygen demand [J].
Chee, GJ ;
Nomura, Y ;
Ikebukuro, K ;
Karube, I .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :67-73
[7]   A novel approach based on ferricyanide-mediator immobilized in an ion-exchangeable biosensing film for the determination of biochemical oxygen demand [J].
Chen, Hailing ;
Ye, T'ingxiu ;
Qiu, Bin ;
Chen, Guonan ;
Chen, Xi .
ANALYTICA CHIMICA ACTA, 2008, 612 (01) :75-82
[8]   Comparison of three microbial assay procedures for measuring toxicity of chemical compounds:: ToxAlert® 10, CellSense and Biolog MT2 microplates [J].
dos Santos, LF ;
Defrenne, L ;
Krebs-Brown, A .
ANALYTICA CHIMICA ACTA, 2002, 456 (01) :41-54
[9]   Toxicity of the 13 priority pollutant metals to Vibrio fisheri in the Microtox® chronic toxicity test [J].
Hsieh, CY ;
Tsai, MH ;
Ryan, DK ;
Pancorbo, OC .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 320 (01) :37-50
[10]   Real time BOD monitoring for wastewater process control [J].
Iranpour, R ;
Straub, B ;
Jugo, T .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1997, 123 (02) :154-159