Water uptake in thin nylon 6 films as measured by electrochemical impedance spectroscopy and magnetic resonance imaging

被引:21
|
作者
Reuvers, N. J. W. [1 ]
Huinink, H. P. [1 ]
Adan, O. C. G. [1 ,2 ]
Garcia, S. J. [3 ]
Mol, J. M. C. [3 ]
机构
[1] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
[2] TNO, Delft, Netherlands
[3] Delft Univ Technol, Delft, Netherlands
关键词
Polyamide; 6; Water uptake; MRI; EIS; Dielectric spectroscopy; ORGANIC COATINGS; PART I; DIELECTRIC-PROPERTIES; DC CONDUCTIVITY; DIFFUSION; NMR; CAPACITANCE; ABSORPTION; TRANSPORT; SORPTION;
D O I
10.1016/j.electacta.2013.01.135
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Electrochemical impedance spectroscopy (EIS) and magnetic resonance imaging (MRI) are used to measure water uptake in nylon 6 films. Based on the EIS data the uptake process is split into three stages. At first, during the first 3 h, the spectrum is mainly capacitive due to the dry bottom part of the film. The existence of a dry bottom part is confirmed by the MRI measurements. In the second stage EIS shows that small traces of water reach the substrate, whereas MRI still not detects water at the nylon/substrate interface. This demonstrates the sensitivity of EIS as water at the substrate is detected by EIS before MRI is able to do so. The last stage starts as the waterfront reaches the substrate and the amount of water in the nylon at the substrate increases. MRI shows that the bulk of the water ingresses into the nylon film as a sharp front. A simple capacitance model is able to link this ingressing front to the impedance as measured with EIS at high frequency. The detection of water breakthrough and interface processes by EIS illustrates the complementarity of the techniques. EIS is able to detect small traces of moisture reaching the substrate before the bulk amount of water does. MRI gives a better view on the overall water distribution during uptake. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:219 / 228
页数:10
相关论文
共 42 条
  • [21] Effects of cold air dehydration on icefish water dynamics and macromolecular oxidation measured by low-field nuclear magnetic resonance and magnetic resonance imaging
    Zhu, Yingying
    Zhang, Li
    Lin, Zhuyi
    Zhang, Zhonghui
    Cao, Yeting
    Ru, Hua
    Yan, Jun
    Li, Shuxian
    Li, Zhong
    FOOD SCIENCE & NUTRITION, 2021, 9 (02): : 736 - 746
  • [22] Determination of water uptake and diffusion of Cl- ion in epoxy primer on aluminum alloys in NaCl solution by electrochemical impedance spectroscopy
    Hu, JM
    Zhang, JQ
    Cao, CN
    PROGRESS IN ORGANIC COATINGS, 2003, 46 (04) : 273 - 279
  • [23] Water sorption and diffusional properties of a cured epoxy resin measured using alternating ionic liquids/aqueous electrolytes in electrochemical impedance spectroscopy
    Hinderliter, Brian R.
    Allahar, Kerry N.
    Bierwagen, Gordon P.
    Tallman, Dennis E.
    Croll, Stuart G.
    JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, 2008, 5 (04) : 431 - 438
  • [24] Water sorption and diffusional properties of a cured epoxy resin measured using alternating ionic liquids/aqueous electrolytes in electrochemical impedance spectroscopy
    Brian R. Hinderliter
    Kerry N. Allahar
    Gordon P. Bierwagen
    Dennis E. Tallman
    Stuart G. Croll
    Journal of Coatings Technology and Research, 2008, 5 : 431 - 438
  • [25] Cardiac effort and 6-min walk distance correlate with stroke volume measured by cardiac magnetic resonance imaging
    Lachant, Daniel J.
    Lachant, Michael D.
    Haight, Deborah
    White, R. James
    PULMONARY CIRCULATION, 2024, 14 (02)
  • [26] Developmental changes in NMDA-induced cell swelling and its transition to necrosis measured with H-1 magnetic resonance imaging, impedance and histology
    Campagne, MV
    Verheul, HB
    Vermeulen, JP
    Balazs, R
    Boer, GJ
    Nicolay, K
    DEVELOPMENTAL BRAIN RESEARCH, 1996, 93 (1-2): : 109 - 119
  • [27] Arrangement of n-type ZnO and p-type NiO nanofibrous thin films on FTO electrode for electrochemical impedance spectroscopy of glucose biosensors
    Jokar, Alireza Khodadadi
    Torabi, Sobhan
    Mirzaei, Majid
    Dabir, Fatemeh
    Bakhtiargonbadi, Fatemeh
    Esfahani, Hamid
    SURFACES AND INTERFACES, 2025, 56
  • [28] Combination of Solid-State and Electrochemical Impedance Spectroscopy To Explore Effects of Porosity in Sol-Gel-Derived BaTiO3 Thin Films
    Whittam, Joshua
    Hector, Andrew L.
    Kavanagh, Christopher
    Owen, John R.
    Reid, Gillian
    ACS OMEGA, 2018, 3 (06): : 6880 - 6887
  • [29] Reproducibility of cerebral blood flow, oxygen metabolism, and lactate and N-acetyl-aspartate concentrations measured using magnetic resonance imaging and spectroscopy
    Madsen, Signe Sloth
    Lindberg, Ulrich
    Asghar, Sohail
    Olsen, Karsten Skovgaard
    Moller, Kirsten
    Larsson, Henrik Bo Wiberg
    Vestergaard, Mark Bitsch
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [30] Rapid and Progressive Regional Brain Atrophy in CLN6 Batten Disease Affected Sheep Measured with Longitudinal Magnetic Resonance Imaging
    Sawiak, Stephen J.
    Perumal, Sunthara Rajan
    Rudiger, Skye R.
    Matthews, Loren
    Mitchell, Nadia L.
    McLaughlan, Clive J.
    Bawden, C. Simon
    Palmer, David N.
    Kuchel, Timothy
    Morton, A. Jennifer
    PLOS ONE, 2015, 10 (07):