Endothelial Cell Viability of Donor Corneas Preserved in Eusol-C Corneal Storage Medium

被引:7
作者
Yuksel, Bora [1 ]
Uzunel, Umut Duygu [1 ]
Kusbeci, Tuncay [1 ]
机构
[1] Izmir Bozyaka Training & Res Hosp, Dept Ophthalmol, Saim Cikrikci Cd 59, Izmir, Turkey
关键词
Eusol-C; Corneal storage medium; Endothelial cell density;
D O I
10.6002/ect.2014.0295
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Objectives: To evaluate the efficacy of Eusol-C as a corneal storage medium on the survival of donor endothelium. Materials and Methods: Twenty-seven corneas not suitable for transplant were included in this study. All donor corneas were stored in Eusol-C at 4 degrees C. Daily donor corneal endothelial cell counting was performed with an eye bank specular microscope. All corneas were discarded after the study process. Results: Mean donor age was 51.3 +/- 18.8 years (range, 25-94 y). The mean duration between death and corneal excision was 9.5 +/- 6.7 hours (range, 3-23 h). Mean endothelial cell density was 2195 +/- 383 cells/mm(2) at the beginning of the preservation (range, 1361-2899 cells/mm(2)). Donor endothelial cell density was between 1500 to 2000 cells/mm(2) in 9 corneas, 2000 to 2500 in 11 corneas, 2500 to 3000 in 5, and higher than 3000 in 2 corneas at baseline. Mean endothelial cell density was found 1658 cells/mm(2) on the eighth day of storage, with a mean endothelial cell loss rate of 24.5%. Corneas stored 9 to 24 days in Eusol-C had a rate of endothelial cell damage of 3.1% per day. Conclusions: Although our results revealed a higher endothelial cell loss than previous reports, overall performance of Eusol-C in preserving the donor endothelium may be satisfactory for clinical use.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 12 条
  • [1] BASU PK, 1974, CAN J OPHTHALMOL, V9, P229
  • [2] Basu Prasanta Kumar, 1995, Indian Journal of Ophthalmology, V43, P55
  • [3] Baumann G., 1994, Ophthalmologe, V91, P624
  • [4] Chaibpracob J, 2006, EYE BANK ASS AM EBAA
  • [5] The Use of Glycerol-preserved Corneas in the Developing World
    Feilmeier, Michael R.
    Tabin, Geoff Rey C.
    Williams, Lloyd
    Oliva, Matt
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2010, 17 (01) : 38 - 43
  • [6] Comparing quantitative and qualitative indices of the donated corneas maintained in Optisol-GS with those kept in Eusol-C
    Kanavi, Mozhgan Rezaei
    Javadi, Mohammad Ali
    Chamani, Tahereh
    Fahim, Pejman
    Javadi, Fatemeh
    [J]. CELL AND TISSUE BANKING, 2015, 16 (02) : 243 - 247
  • [7] OPTISOL CORNEAL STORAGE MEDIUM
    LINDSTROM, RL
    KAUFMAN, HE
    SKELNIK, DL
    LAING, RA
    LASS, JH
    MUSCH, DC
    TROUSDALE, MD
    REINHART, WJ
    BURRIS, TE
    SUGAR, A
    DAVIS, RM
    HIROKAWA, K
    SMITH, T
    GORDON, JF
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 114 (03) : 345 - 356
  • [8] VIABILITY OF HUMAN CORNEAL ENDOTHELIUM FOLLOWING OPTISOL-GS STORAGE
    MEANS, TL
    GEROSKI, DH
    HADLEY, A
    LYNN, MJ
    EDELHAUSER, HF
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (06) : 805 - 809
  • [9] Mizukawa T, 1968, Nihon Ganka Kiyo, V19, P1310
  • [10] In vitro comparison of Chen medium and Optisol-GS medium for human corneal storage
    Nelson, LR
    Hodge, DO
    Bourne, WM
    [J]. CORNEA, 2000, 19 (06) : 782 - 787