Describing the active region boundary of EMG-assisted biomechanical models of the low back
被引:26
作者:
Ning, Xiaopeng
论文数: 0引用数: 0
h-index: 0
机构:
Iowa State Univ, Dept Ind & Mfg Syst Engn, Ergon Lab, Ames, IA 50011 USA
W Virginia Univ, Morgantown, WV 26505 USAIowa State Univ, Dept Ind & Mfg Syst Engn, Ergon Lab, Ames, IA 50011 USA
Ning, Xiaopeng
[1
,2
]
Jin, Sangeun
论文数: 0引用数: 0
h-index: 0
机构:
Iowa State Univ, Dept Ind & Mfg Syst Engn, Ergon Lab, Ames, IA 50011 USAIowa State Univ, Dept Ind & Mfg Syst Engn, Ergon Lab, Ames, IA 50011 USA
Jin, Sangeun
[1
]
论文数: 引用数:
h-index:
机构:
Mirka, Gary A.
[1
]
机构:
[1] Iowa State Univ, Dept Ind & Mfg Syst Engn, Ergon Lab, Ames, IA 50011 USA
Background: Electromyography-assisted (EMG-assisted) biomechanical models are used to characterize the muscle and joint reaction forces in the lumbar region. However, during a full-range trunk flexion, there is a transition of extension moment from the trunk extensor muscles to the passive tissues of the low back, indicating that the empirical EMG data used to drive these EMG-assisted models becomes less correlated with the extensor moment. The objectives of this study were to establish the trunk flexion angles at which the passive tissues generate substantial trunk extension moment and to document how these angles change with asymmetry. Methods: Participants performed controlled trunk flexion-extension motions in three asymmetric postures. The trunk kinematics data and the electromyographic activity from L3- and L4-level paraspinals and rectus abdominis were captured. The time-dependent net internal active moment (from an EMG-assisted model) and the net external moment were calculated. The trunk and lumbar angles at which the net internal active moment was less than 70% of the external moment were found. Findings: The trunk flexion angle at which the net internal moment reaches the stated criteria varied as a function of asymmetry of trunk flexion motion with the sagittally symmetric case providing the deepest flexion angle of 38 degrees (asymmetry 15 degrees: 33 degrees; asymmetry 30 degrees: 26 degrees). Interpretation: These results indicate that EMG-assisted biomechanical models need to consider the role of passive tissues at trunk flexion angles significantly less than previously thought and these flexion angles vary as a function of the asymmetry and direction of motion. (C) 2011 Elsevier Ltd. All rights reserved.
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
Baratta, RV
Solomonow, M
论文数: 0引用数: 0
h-index: 0
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
Solomonow, M
Nguyen, G
论文数: 0引用数: 0
h-index: 0
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
Nguyen, G
D'Ambrosia, R
论文数: 0引用数: 0
h-index: 0
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
Baratta, RV
Solomonow, M
论文数: 0引用数: 0
h-index: 0
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
Solomonow, M
Nguyen, G
论文数: 0引用数: 0
h-index: 0
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA
Nguyen, G
D'Ambrosia, R
论文数: 0引用数: 0
h-index: 0
机构:
Tulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USATulane Univ, Med Ctr, Dept Orthopaed Surg, Bioengn Lab, New Orleans, LA 70112 USA