A Review of Biomaterials and Associated Performance Metrics Analysis in Pre-Clinical Finite Element Model and in Implementation Stages for Total Hip Implant System

被引:20
作者
Soliman, Md Mohiuddin [1 ]
Chowdhury, Muhammad E. H. [2 ]
Islam, Mohammad Tariqul [3 ]
Musharavati, Farayi [4 ]
Nabil, Mohammad [2 ]
Hafizh, Muhammad [4 ]
Khandakar, Amith [2 ]
Mahmud, Sakib [2 ]
Nezhad, Erfan Zal [5 ]
Shuzan, Md Nazmul Islam [1 ]
Abir, Farhan Fuad [2 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Bangi 43600, Selangor, Malaysia
[2] Qatar Univ, Dept Elect Engn, Doha 2713, Qatar
[3] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Elect Elect & Syst Engn, Ctr Adv Elect & Commun Engn, Bangi 43600, Selangor, Malaysia
[4] Qatar Univ, Dept Mech & Ind Engn, Doha 2713, Qatar
[5] Univ Texas San Antonio, Dept Biomed Engn, San Antonio, TX 78249 USA
关键词
total hip implant; finite element analysis; stress distribution; micromotion; wear; biocompatibility; METAL-ON-METAL; POLYETHYLENE WEAR; FATIGUE BEHAVIOR; ORTHOPEDIC IMPLANTS; BEARING SURFACES; ALPHA-TOCOPHEROL; SEX-DIFFERENCES; YOUNGS MODULUS; TAPER JUNCTION; FEMORAL STEM;
D O I
10.3390/polym14204308
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Total hip replacement (THR) is a common orthopedic surgery technique that helps thousands of individuals to live normal lives each year. A hip replacement replaces the shattered cartilage and bone with an implant. Most hip implants fail after 10-15 years. The material selection for the total hip implant systems is a major research field since it affects the mechanical and clinical performance of it. Stress shielding due to excessive contact stress, implant dislocation due to a large deformation, aseptic implant loosening due to the particle propagation of wear debris, decreased bone remodeling density due to the stress shielding, and adverse tissue responses due to material wear debris all contribute to the failure of hip implants. Recent research shows that pre-clinical computational finite element analysis (FEA) can be used to estimate four mechanical performance parameters of hip implants which are connected with distinct biomaterials: von Mises stress and deformation, micromotion, wear estimates, and implant fatigue. In vitro, in vivo, and clinical stages are utilized to determine the hip implant biocompatibility and the unfavorable local tissue reactions to different biomaterials during the implementation phase. This research summarizes and analyses the performance of the different biomaterials that are employed in total hip implant systems in the pre-clinical stage using FEA, as well as their performances in in vitro, in vivo, and in clinical studies, which will help researchers in gaining a better understanding of the prospects and challenges in this field.
引用
收藏
页数:27
相关论文
共 143 条
[1]  
American Joint Replacement Registry, 2020, RES 2020 AM JOINT RE
[2]   Correlation between serum metal ion levels and adverse local tissue reactions after Conserve® Plus hip resurfacing arthroplasty [J].
Amstutz, Harlan C. ;
Le Duff, Michel J. .
HIP INTERNATIONAL, 2017, 27 (04) :336-342
[3]   Prediction of micromotion initiation of an implanted femur under physiological loads and constraints using the finite element method [J].
Andreaus, U. ;
Colloca, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H5) :589-605
[4]   Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis [J].
Anguiano-Sanchez, Jesica ;
Martinez-Romero, Oscar ;
Siller, Hector R. ;
Diaz-Elizondo, Jose A. ;
Flores-Villalba, Eduardo ;
Rodriguez, Ciro A. .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
[5]  
[Anonymous], OT HIP SYST
[6]  
[Anonymous], 2001, 1154212001 ISO
[7]  
Ben-Nissan S.C.B., 2019, BIOCERAMICS, P14
[8]   Synthesis and characterisation of a new superelastic Ti-25Ta-25Nb biomedical alloy [J].
Bertrand, E. ;
Gloriant, T. ;
Gordin, D. M. ;
Vasilescu, E. ;
Drob, P. ;
Vasilescu, C. ;
Drob, S. I. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (08) :559-564
[9]  
Billi F, 2010, J APPL BIOMATER BIOM, V8, P1
[10]   High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS [J].
Bolland, B. J. R. F. ;
Culliford, D. J. ;
Langton, D. J. ;
Millington, J. P. S. ;
Arden, N. K. ;
Latham, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :608-615