Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems

被引:431
作者
Mayagoitia, RE
Nene, AV
Veltink, PH
机构
[1] Staffordshire Univ, Stoke On Trent ST4 2DF, Staffs, England
[2] Roessingh Rehabil Inst, Enschede, Netherlands
[3] Univ Twente, Biomed Technol Inst, NL-7500 AE Enschede, Netherlands
关键词
accelerometer; gyroscope; gait kinematics; portable gait analysis; knee moment;
D O I
10.1016/S0021-9290(01)00231-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A general-purpose system to obtain the kinematics of gait in the sagittal plane based on body-mounted sensors was developed. It consisted of four uniaxial seismic accelerometers and one rate gyroscope per body segment. Tests were done with 10 young healthy volunteers, walking at five different speeds on a treadmill. In order to study the system's accuracy, measurements were made with an optic, passive-marker system and the body-mounted system, simultaneously. In all the comparison cases, the curves obtained from the two systems were very close, showing root mean square errors representing <7% full range in 75% of the cases (overall mean 6.64%, standard deviation 4.13%) and high coefficients of multiple correlation in 100% of cases (overall mean 0.9812, standard deviation 0.02). Calibration of the body-mounted system is done against gravity. The body-mounted sensors do not hinder natural movement. The calculation algorithms are computationally demanding and only are applicable off-line. The body-mounted sensors are accurate, inexpensive and portable and allow long-term recordings in clinical, sport and ergonomics settings. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 13 条
[2]  
Bussmann J.B.J., 1995, EUR J PHYS MED REHAB, V5, P2
[3]  
Dai R, 1996, IEEE Trans Rehabil Eng, V4, P63, DOI 10.1109/86.506403
[4]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[5]  
Lotters JC, 1998, SENSOR ACTUAT A-PHYS, V68, P221, DOI 10.1016/S0924-4247(98)00049-1
[6]  
Luinge H J, 1999, Technol Health Care, V7, P455
[7]   Assessment of rectus femoris function during initial swing phase [J].
Nene, A ;
Mayagoitia, R ;
Veltink, P .
GAIT & POSTURE, 1999, 9 (01) :1-9
[8]   A practical gait analysis system using gyroscopes [J].
Tong, KY ;
Granat, MH .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (02) :87-94
[9]   A method for inverse dynamic analysis using accelerometry [J].
vandenBogert, AJ ;
Read, L ;
Nigg, BM .
JOURNAL OF BIOMECHANICS, 1996, 29 (07) :949-954
[10]  
Veltink P H, 1996, IEEE Trans Rehabil Eng, V4, P375, DOI 10.1109/86.547939