Assessing the Environmental Impact of Thermal Transmittance Tests Performed in Facades of Existing Buildings: The Case of Spain

被引:9
作者
Bienvenido-Huertas, David [1 ]
机构
[1] Univ Seville, Dept Bldg Construct 2, Seville 41012, Spain
关键词
thermal transmittance test; buildings; facade; energy consumption; CO2; emissions; IN-SITU MEASUREMENT; INFRARED THERMOGRAPHY; U-VALUE; ENERGY PERFORMANCE; OPTIMIZATION; RESISTANCE; MASONRIES; STANDARD; BEHAVIOR; WALLS;
D O I
10.3390/su12156247
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Thermal transmittance tests constitute an appropriate tool to assess the energy performance of existing buildings. The heat flow meter method and the thermometric method are the most used experimental methods. One of the main criteria to guarantee appropriate test conditions and the representation of results is to ensure a high thermal gradient. For this purpose, heating or air conditioning systems should be used from three to seven days. Most studies related to experimental methods have addressed the appropriate test conditions; however, the environmental impact related to these conditions have not been analyzed. This study analyzes the energy consumption and the CO2 emissions related to the conditions of the thermal gradient required for tests. An energy analysis of 129,600 cases located in Spain was conducted. The results showed that heating systems are the best option to perform thermal transmittance tests, whereas air conditioning systems do not guarantee appropriate test conditions. As for the energy consumption and the percentage of hours with an appropriate thermal gradient, the adequacy of the heating setpoint temperature according to the predicted estimations of the external temperature during tests would mitigate their environmental impact. The reason is that, in certain cases, the increase of the setpoint temperature does not improve test conditions. Also, the use of heating systems would imply short test durations. Finally, the selection of small rooms with a small facade length would reduce the percentage of CO2 emissions between 31.37% and 36.1%. The results of this study could guarantee a more sustainable performance of thermal transmittance tests. In addition, the results could be used to perform life cycle analysis on buildings where thermal transmittance tests are performed.
引用
收藏
页数:18
相关论文
共 55 条
  • [1] In situ measurement of thermal transmittance and thermal resistance of hollow reinforced precast concrete walls
    Ahmad, Aftab
    Maslehuddin, Mohammed
    Al-Hadhrami, Luai M.
    [J]. ENERGY AND BUILDINGS, 2014, 84 : 132 - 141
  • [2] A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance
    Albatici, Rossano
    Tonelli, Arnaldo M.
    Chiogna, Michela
    [J]. APPLIED ENERGY, 2015, 141 : 218 - 228
  • [3] Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site
    Albatici, Rossano
    Tonelli, Arnaldo M.
    [J]. ENERGY AND BUILDINGS, 2010, 42 (11) : 2177 - 2183
  • [4] A New Metre for Cheap, Quick, Reliable and Simple Thermal Transmittance (U-Value) Measurements in Buildings
    Andujar Marquez, Jose Manuel
    Martinez Bohorquez, Miguel Angel
    Gomez Melgar, Sergio
    [J]. SENSORS, 2017, 17 (09):
  • [5] [Anonymous], REV CONSTR
  • [6] [Anonymous], 2014, ISO 9869-1
  • [7] [Anonymous], 2011, ROADMAP TRANSFORMING
  • [8] [Anonymous], 2006, ACT PLAN EN EFF REAL
  • [9] Asdrubali F., 2014, CASE STUD CONSTR MAT, V1, P53, DOI DOI 10.1016/J.CSCM.2014.04.004
  • [10] A comparative assessment of the standardized methods for the in-situ measurement of the thermal resistance of building walls
    Atsonios, Ioannis A.
    Mandilaras, Loannis D.
    Kontogeorgos, Dimos A.
    Founti, Maria A.
    [J]. ENERGY AND BUILDINGS, 2017, 154 : 198 - 206