Determination of eight artificial sweeteners in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry

被引:42
作者
Kokotou, Maroula G. [1 ]
Thomaidis, Nikolaos S. [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, Athens 15771, Greece
关键词
SOLID-PHASE EXTRACTION; STATIONARY PHASES; SURFACE WATERS; SUCRALOSE; PERFORMANCE; SAMPLES; CONTAMINANTS; SELECTIVITY; SEPARATION; RETENTION;
D O I
10.1039/c3ay40599k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a method for the simultaneous determination of eight artificial sweeteners, namely aspartame (ASP), alitame (ALI), neotame (NEO), acesulfame (ACS), saccharin (SAC), cyclamate (CYC), sucralose (SCL) and neohesperidin dihydrochalcone (NHDC), under hydrophilic interaction liquid chromatography (HILIC) conditions is presented herein. The ionization of all the compounds was achieved by negative electrospray. Two silica-based columns, a fully porous (XBridge HILIC) and a fused-core one (Kinetex HILIC), were compared. For HILIC optimization, the effect of the following parameters was studied: the mobile phase, column temperature, pH and ionic strength of the ammonium formate buffer. The optimized mobile phase was 5 mM ammonium formate buffer pH 3.5-methanol-acetonitrile (15/10/75 v/v), with a flow rate of 100 mu L min(-1) at 50 degrees C. The asymmetry factor of the peaks was lower on the Kinetex HILIC column than that on the XBridge HILIC. The predominant retention mechanism of all the analytes on silica columns seems to be partition to the aqueous layer. The method was validated in tap water and wastewater samples using Kinetex HILIC. Three deuterated internal standards were used, one for each category of sweeteners (dipeptides, sulfamates and sugars). The instrumental limits of detection ranged from 0.24 (SAC) to 4.4 (SCL) mu g L-1. The recoveries in influent samples ranged from 39% (CYC) to 97% (NEO), while recoveries were better for the other two matrices. Inter-day precision (% RSD, n = 6) ranged from 4.2% (SAC) to 20% (ALI) in influent samples. The method was applied to influents and effluents from the wastewater treatment plant of Athens for seven consecutive days and high levels of sucralose and sulfamates were found.
引用
收藏
页码:3825 / 3833
页数:9
相关论文
共 34 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]   Electrostatic repulsion hydrophilic interaction chromatography for isocratic separation of charged solutes and selective isolation of phosphopeptides [J].
Alpert, Andrew J. .
ANALYTICAL CHEMISTRY, 2008, 80 (01) :62-76
[3]   Stability considerations of aspartame in the direct analysis of artificial sweeteners in water samples using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) [J].
Berset, Jean-Daniel ;
Ochsenbein, Nicole .
CHEMOSPHERE, 2012, 88 (05) :563-569
[4]   Ubiquitous Occurrence of the Artificial Sweetener Acesulfame in the Aquatic Environment: An Ideal Chemical Marker of Domestic Wastewater in Groundwater [J].
Buerge, Ignaz J. ;
Buser, Hans-Rudolf ;
Kahle, Maren ;
Mueller, Markus D. ;
Poiger, Thomas .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (12) :4381-4385
[5]   Determination of isoascorbic acid in fish tissue by hydrophilic interaction liquid chromatography-ultraviolet detection [J].
Drivelos, Spyros ;
Dasenaki, Marilena E. ;
Thomaidis, Nikolaos S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) :2199-2210
[6]   Analysis of sucralose and other sweeteners in water and beverage samples by liquid chromatography/time-of-flight mass spectrometry [J].
Ferrer, Imma ;
Thurman, E. Michael .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (25) :4127-4134
[7]   Hydrophilic interaction chromatography [J].
Gama, Mariana Roberto ;
da Costa Silva, Raquel Gomes ;
Collins, Carol H. ;
Bottoli, Carla B. G. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 37 :48-60
[8]   A novel solid-phase extraction for the concentration of sweeteners in water and analysis by ion-pair liquid chromatography-triple quadrupole mass spectrometry [J].
Gan, Zhiwei ;
Sun, Hongwen ;
Wang, Ruonan ;
Feng, Biting .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1274 :87-96
[9]   Physical properties and structure of fine core-shell particles used as packing materials for chromatography Relationships between particle characteristics and column performance [J].
Gritti, Fabrice ;
Leonardis, Irene ;
Abia, Jude ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (24) :3819-3843
[10]   Retention and selectivity of stationary phases for hydrophilic interaction chromatography [J].
Guo, Yong ;
Gaiki, Sheetal .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (35) :5920-5938