Amnioreduction in emergency cerclage with prolapsed membranes: Comparison of two methods for reducing the membranes

被引:38
作者
Locatelli, A [1 ]
Vergani, P [1 ]
Bellini, P [1 ]
Strobelt, N [1 ]
Arreghini, A [1 ]
Ghidini, A [1 ]
机构
[1] Ist Sci Biomed San Gerardo, Dept Obstet & Gynecol, Monza, Italy
关键词
cerclage; amnioreduction; prematurity; preterm delivery;
D O I
10.1055/s-2007-993839
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To evaluate the effectiveness of amnioreduction in pregnancies requiring emergency cerclage placement, we performed a retrospective case-control study of all consecutive pregnant women with cervical dilation and effacement with prolapse of the fetal membranes in vagina between 16 and 26 weeks' gestation, who required placement of a McDonald emergency cerclage during the period January 1991-December 1997. Duration of pregnancy prolongation, rate of delivery before 32 weeks, and duration of neonatal hospital stay were compared between women in whom amniochorionic membranes were reduced at the time of cerclage placement using only intracervical Foley balloon catheter (controls; n = 7) and those who in addition underwent amnioreduction to facilitate cerclage placement (n=9). Statistical analysis utilized Fisher's exact test and Wilcoxon rank sum test. A p value <0.05 was considered significant. There were no procedure-related ruptures of membranes. Gestational age at cerclage and rate of positive cervico-vaginal cultures were not different between the two groups. Gestation was prolonged for a median of 100 days (range 4 to 144 days) in the amnioreduction group and 10 days (2 to 133) among controls (p = 0.3). The rate of delivery before 32 weeks was significantly lower (1/7 vs. 6/8, p 0.03) and the duration of neonatal hospital admission significantly shorter (median 3 vs. 37 days, p=0.001) in the amnioreduction group than among controls. The amount of amniotic fluid withdrawn ranged from 220 to 340 mt. These findings suggest that amnioreduction at the time of emergency cerclage placement is associated with a lower rate of extreme prematurity and related neonatal morbidity.
引用
收藏
页码:73 / 77
页数:5
相关论文
共 15 条
[1]  
Aarts J M, 1995, Obstet Gynecol Surv, V50, P459, DOI 10.1097/00006254-199506000-00022
[2]  
GOODLIN RC, 1979, OBSTET GYNECOL, V54, P748
[3]  
GOODLIN RC, 1987, SURG GYNECOL OBSTET, V165, P410
[4]   EMERGENCY CERVICAL CERCLAGE USING A METREURYNTER IN PATIENTS WITH BULGING MEMBRANES [J].
HIGUCHI, M ;
HIRANO, H ;
MAKI, M .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1992, 71 (01) :34-38
[5]  
MCDOUGALL J, 1991, BRIT J OBSTET GYNAEC, V98, P1234
[6]   EMERGENCY CERCLAGES - A REVIEW OF 40 CONSECUTIVE PROCEDURES [J].
MITRA, AG ;
KATZ, VL ;
BOWES, WA ;
CARMICHAEL, S .
AMERICAN JOURNAL OF PERINATOLOGY, 1992, 9 (03) :142-145
[7]   NEW PERSPECTIVES ON THE PREVENTION OF EXTREME PREMATURITY [J].
NOVY, MJ ;
MCGREGOR, JA ;
IAMS, JD .
CLINICAL OBSTETRICS AND GYNECOLOGY, 1995, 38 (04) :790-808
[8]   SHIRODKAR CERCLAGE IN A MULTIFACTORIAL APPROACH TO THE PATIENT WITH ADVANCED CERVICAL CHANGES [J].
NOVY, MJ ;
HAYMOND, J ;
NICHOLS, M .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 162 (06) :1412-1420
[9]  
OLATUNBOSUN OA, 1981, OBSTET GYNECOL, V57, P166
[10]   INFECTION AND LABOR .8. MICROBIAL INVASION OF THE AMNIOTIC CAVITY IN PATIENTS WITH SUSPECTED CERVICAL INCOMPETENCE - PREVALENCE AND CLINICAL-SIGNIFICANCE [J].
ROMERO, R ;
GONZALEZ, R ;
SEPULVEDA, W ;
BRANDT, F ;
RAMIREZ, M ;
SOROKIN, Y ;
MAZOR, M ;
TREADWELL, MC ;
COTTON, DB .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 167 (04) :1086-1091