Detection of Escherichia coli O157:H7 in 10-and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides

被引:66
作者
DeMarco, DR [1 ]
Lim, DV [1 ]
机构
[1] Univ S Florida, Dept Biol, Tampa, FL 33620 USA
关键词
D O I
10.4315/0362-028X-65.4.596
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A portable evanescent-wave fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded 10- and 25-g ground beef samples. The biosensor works by launching light from a 635-nm laser diode into specially designed optical fiber probes, generating an evanescent field that extends approximately 1,000 run from the fiber surface. Fluorescent molecules within the evanescent field are excited, and a portion of their emission recouples into the fiber probe. The return path emission is transported by an optical fiber to a photodiode within the biosensor that detects and quantifies the fluorescent signal. A sandwich immunoassay was performed on the fiber probes with cyanine 5 dye-labeled polyclonal anti-E, coli O157:117 antibodies for generation of the specific fluorescent signal. Biotin-streptavidin interactions were used to attach polyclonal anti-E. coli O157:117 antibodies to the surface of the fiber probe. A centrifugation method was developed to obtain samples suitable for biosensor analysis from 10- and 25-g ground beef samples. The assay was shown to be sensitive and repeatable. One hundred percent correct identification of positive samples was demonstrated at 9.0 X 10(3) CFU/g for 25-g ground beef samples with silica waveguides and at 5.2 X 10(2) CFU/g for 10-g ground beef samples with polystyrene waveguides. The reaction was highly specific. No false positives were observed for 10-g ground beef samples not spiked with the pathogen, In addition, when samples were spiked with high concentrations of a variety of non-E. coli O157:117 organisms, no false positives were observed. The method was rapid, with results being obtained within 25 min of sample processing.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 29 条
[1]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[2]   Assay development for a portable fiberoptic biosensor [J].
Anderson, GP ;
Breslin, KA ;
Ligler, FS .
ASAIO JOURNAL, 1996, 42 (06) :942-946
[3]   A MULTISTATE OUTBREAK OF ESCHERICHIA-COLI-O157-H7 ASSOCIATED BLOODY DIARRHEA AND HEMOLYTIC-UREMIC-SYNDROME FROM HAMBURGERS - THE WASHINGTON EXPERIENCE [J].
BELL, BP ;
GOLDOFT, M ;
GRIFFIN, PM ;
DAVIS, MA ;
GORDON, DC ;
TARR, PI ;
BARTLESON, CA ;
LEWIS, JH ;
BARRETT, TJ ;
WELLS, JG ;
BARON, R ;
KOBAYASHI, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (17) :1349-1353
[4]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[5]   Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli O157:H7 [J].
Brewster, JD ;
Mazenko, RS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 211 (1-2) :1-8
[6]   DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR [J].
CAO, LK ;
ANDERSON, GP ;
LIGLER, FS ;
EZZELL, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) :336-341
[7]   Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor [J].
DeMarco, DR ;
Saaski, EW ;
McCrae, DA ;
Lim, DV .
JOURNAL OF FOOD PROTECTION, 1999, 62 (07) :711-716
[8]   Portable multichannel fiber optic biosensor for field detection [J].
Golden, JP ;
Saaski, EW ;
ShriverLake, LC ;
Anderson, GP ;
Ligler, FS .
OPTICAL ENGINEERING, 1997, 36 (04) :1008-1013
[9]   THE EPIDEMIOLOGY OF INFECTIONS CAUSED BY ESCHERICHIA-COLI O157-H7, OTHER ENTEROHEMORRHAGIC ESCHERICHIA-COLI, AND THE ASSOCIATED HEMOLYTIC UREMIC SYNDROME [J].
GRIFFIN, PM ;
TAUXE, RV .
EPIDEMIOLOGIC REVIEWS, 1991, 13 :60-98
[10]  
Hitchins A. D., 1995, Bacteriological Analytical Manual, BAM-8