Design and evaluation of a single-pivot supported centrifugal blood pump

被引:11
|
作者
Yoshino, M
Uemura, T
Takahashi, T
Watanabe, T
Hoshi, H
Ohuchi, K
Nakamura, M
Fujita, H
Sakamoto, T
Takatani, S
机构
[1] Tokyo Med & Dent Univ, Dept Artificial Organs, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo, Japan
[2] Nihon Univ, Coll Sci & Technol, Dept Mech Engn, Tokyo 102, Japan
[3] Shibaura Inst Technol, Dept Engn Mech, Tokyo 108, Japan
[4] Tokyo Denki Univ, Fac Sci & Engn, Dept Appl Elect Engn, Tokyo 101, Japan
[5] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Dept Thorac Organ Replacement, Tokyo, Japan
关键词
single-pivot bearing system; centrifugal blood pump; ventricular assist device; sealless continuous flow pump;
D O I
10.1046/j.1525-1594.2001.06856.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to develop a centrifugal blood pump that meets the requirements of a long-term, implantable circulatory support device, in this study a sing e-pivot bearing supported centrifugal blood pump was designed to evaluate its basic performance. The single-pivot structure consisted of a ceramic ball male pivot mounted on the bottom surface of the impeller and a polyethylene female pivot incorporated in the bottom pump casing. The follower magnet mounted inside the impeller was magnetically coupled to the driver magnet mounted on the shaft of the direct current brushless motor. As the motor rotated, the impeller rotated supported entirely by a single-pivot bearing system. The static pump performance obtained in the mock circulatory loop revealed an acceptable performance as a left ventricular assist device in terms of flow and head pressure. The pump flow of 5 L/min against the head pressure of 100 mm Hg was obtained at rotational speeds of 2,000 to 2,200 rpm. The maximum pump flow was 9 L/min with 2,200 rpm. The maximum electrical-to-hydraulic power conversion efficiency was around 14% at pump flows of 4 to 5 L/min. The stability of the impeller was demonstrated at the pump rpm higher than 1,400 with a single-pivot bearing without an additional support at its top. The single-pivot supported centrifugal pump can provide adequate flow and pressure as a ventricular assist device, but its mechanical stability and hemolytic as well as thrombotic performances must be tested prior to clinical use.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 50 条
  • [41] A new design for a compact centrifugal blood pump with a magnetically levitated rotor
    Asama, J
    Shinshi, T
    Hoshi, H
    Takatani, S
    Shimokohbe, A
    ASAIO JOURNAL, 2004, 50 (06) : 550 - 556
  • [42] Analysis of optimal design configurations for a multiple disk centrifugal blood pump
    Miller, GE
    Fink, R
    ARTIFICIAL ORGANS, 1999, 23 (06) : 559 - 565
  • [43] The Centrifugal Pump with the Impeller Supported in Sealing Clearances
    Wladimir, Marcinkowski
    Andrzej, Korczak
    Czeslaw, Kundera
    TEROTECHNOLOGY, 2014, 874 : 83 - +
  • [44] Preclinical evaluation of the Kyocera Gyro centrifugal blood pump for cardiopulmonary bypass
    Takami, Yoshiyuki
    Ohara, Yasuhisa
    Otsuka, Goro
    Nakazawa, Tadashi
    Nose, Yukihiko
    PERFUSION-UK, 1997, 12 (05): : 335 - 341
  • [45] Evaluation of platelet adhesion and activation on materials for an implantable centrifugal blood pump
    Takami, Y
    Yamane, S
    Makinouchi, K
    Niimi, Y
    Sueoka, A
    Nose, Y
    ARTIFICIAL ORGANS, 1998, 22 (09) : 753 - 758
  • [46] New centrifugal blood pump with dual impeller and double pivot bearing system: Wear evaluation in bearing system, performance tests, and preliminary hemolysis tests
    Bock, Eduardo
    Ribeiro, Adriana
    Silva, Maxwell
    Antunes, Pedro
    Fonseca, Jeison
    Legendre, Daniel
    Leme, Juliana
    Arruda, Celso
    Biscegli, Jose
    Nicolosi, Denys
    Andrade, Aron
    ARTIFICIAL ORGANS, 2008, 32 (04) : 329 - 333
  • [47] Design and analysis of a radial diffuser in a single-stage centrifugal pump
    Tan, Ming-Gao
    He, Xiang-Hui
    Liu, Hou-Lin
    Dong, Liang
    Wu, Xian-Fang
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2016, 10 (01) : 500 - 511
  • [48] Noninvasive pump flow estimation of a centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Nakatani, T
    Tatsumi, E
    Nishimura, T
    Takewa, Y
    Ohno, T
    Takano, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 651 - 654
  • [49] Implantable Centrifugal Blood Pump With Dual Impeller and Double Pivot Bearing System: Electromechanical Actuator, Prototyping, and Anatomical Studies
    Bock, Eduardo
    Antunes, Pedro
    Leao, Tarcisio
    Uebelhart, Beatriz
    Fonseca, Jeison
    Leme, Juliana
    Utiyama, Bruno
    da Silva, Cibele
    Cavalheiro, Andre
    Santos Filho, Diolino
    Dinkhuysen, Jarbas
    Biscegli, Jose
    Andrade, Aron
    Arruda, Celso
    ARTIFICIAL ORGANS, 2011, 35 (05) : 437 - 442
  • [50] NUMERICAL INVESTIGATIONS OF A CENTRIFUGAL BLOOD PUMP
    Chan, W. K.
    Wong, Y. W.
    Ding, Y.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2004, 4 (03) : 237 - 255