共 25 条
Cross-cultural Adaptation and Measurement Properties of the Brazilian Portuguese Version of the Victorian Institute of Sport Assessment-Patella (VISA-P) Scale
被引:34
作者:
Wageck, Bruna Borges
[1
]
de Noronha, Marcos Amaral
[1
,2
]
Lopes, Alexandre Dias
[3
]
da Cunha, Ronaldo Alves
[4
]
Takahashi, Ricardo Hisayoshi
[5
]
Pena Costa, Leonardo Oliveira
[3
]
机构:
[1] Univ Estado Santa Catarina, Florianopolis, SC, Brazil
[2] La Trobe Rural Hlth Sch, Bendigo, Vic 3552, Australia
[3] Univ Cidade Sao Paulo, Sao Paulo, Brazil
[4] Univ Fed Sao Paulo, Sports Orthopaed Trauma Ctr, Phys Therapy Dept, Sao Paulo, Brazil
[5] Saude Plena, Sao Paulo, Brazil
关键词:
Brazil;
knee;
patellar tendinopathy;
questionnaire;
tendinopathy;
JUMPERS KNEE;
STATUS QUESTIONNAIRES;
TENDINOPATHY;
RECOMMENDATIONS;
RELIABILITY;
VALIDATION;
SCORE;
D O I:
10.2519/jospt.2013.4287
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
STUDY DESIGN: Clinical measurement. OBJECTIVES: To translate, adapt, and test the measurement properties of the Brazilian Portuguese version of the Victorian Institute of Sport Assessment-Patella (VISA-P) questionnaire. BACKGROUND: It is important to objectively measure symptoms and functional limitations related to patellar tendinopathy using outcome measures that have been validated in the language of the target population. Cross-cultural adaptations are also useful to enhance the understanding of the measurement properties of an assessment tool, regardless of the target language. METHODS: The VISA-P questionnaire was translated into Brazilian Portuguese, culturally adapted, and titled VISA-P Brazil. It was then administered on 2 occasions with a 24- to 48-hour interval between them, and a third time after a month of physical therapy treatment. The following measurement properties were analyzed: internal consistency, test-retest reliability, agreement, construct validity, floor and ceiling effects, and responsiveness. ESULTS: The VISA-P Brazil had high internal consistency (Cronbach alpha =.76; if item deleted, Cronbach alpha = .69-18), excellent reliability and agreement (intraclass correlation coefficient = 0.91; 95% confidence interval: 0.85, 0.95; standard error of measurement, 5.2 points; minimal detectable change at the 90% confidence level, 12.2 points), and good construct validity (Pearson r = 0.60 compared to Lysholm). No ceiling and floor effects were detected for the VISA-P Brazil, and the responsiveness, based on 32 patients receiving physical therapy intervention for 1 month, demonstrated a large effect size of 0.97 (95% confidence interval: 0.68, 1.25). CONCLUSION: The VISA-P Brazil is a reproducible and responsive tool and can be used in clinical practice and research to assess the severity of pain and disability of patients with patellar tendinopathy.
引用
收藏
页码:163 / 171
页数:9
相关论文