Inadvertent intrastromal injection of ophthalmic viscoelastic

被引:2
|
作者
McConnell, Lindsay K. [1 ]
Winter, Timothy W. [1 ]
Olson, Richard J. [1 ]
Longmuir, Susannah Q. [1 ]
机构
[1] Univ Iowa Hosp & Clin, Carver Coll Med, Dept Ophthalmol & Visual Sci, Iowa City, IA 52242 USA
来源
JOURNAL OF AAPOS | 2013年 / 17卷 / 06期
关键词
DETACHMENT;
D O I
10.1016/j.jaapos.2013.07.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Viscoelastic is an ophthalmic viscosurgical device used to protect ocular tissue and maintain intraocular space during surgical procedures such as cataract removal. To date, the only cases published regarding inadvertent viscosurgical device injection have caused Descemet's membrane detachments. We report the case of a 4-year-old girl who underwent complicated lensectomy with prior history of uveitis and posterior synechia in which intrastromal ophthalmic viscoelastic was inadvertently injected into the stroma, leaving an off-centered opacity. At the time of surgery, no Descemet's membrane detachment was seen. The lensectomy and planned anterior vitrectomy were performed without complication and visual acuity has improved from 20/200 preoperatively to 20/70 at 3 months' follow-up. The corneal opacity resolved within 1 week of surgery, with no evidence of residual visual impairment.
引用
收藏
页码:639 / 641
页数:3
相关论文
共 50 条
  • [41] Inadvertent caudal epidural injection of cefazolin
    Mchaourab, A
    Ruiz, F
    ANESTHESIOLOGY, 2001, 94 (01) : 184 - 184
  • [42] INADVERTENT NERVE INJURY FOLLOWING INJECTION
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1958, 167 (18): : 2258 - 2258
  • [43] Inadvertent injection of triamcinolone into the crystalline lens
    Jalil, A.
    Chaudhry, N. L.
    Gandhi, J. S.
    Odat, T. M.
    Yodaiken, M.
    EYE, 2007, 21 (01) : 152 - 154
  • [44] Correction of hyperopia by intrastromal cutting and biocompatible filler injection
    Freidank, Sebastian
    Vogel, Alfred
    Anderson, Richard R.
    Birngruber, Reginald
    Linz, Norbert
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [45] Incorrect Route for Injection: Inadvertent Tranexamic Acid Intrathecal Injection
    AL-Taei, Mustafa H.
    AlAzzawi, Mohammed
    Albustani, Safa
    Alsaoudi, Ghadier
    Costanzo, Eric
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
  • [46] Toxicity of Intrastromal Voriconazole Injection on Corneal Endothelium in Rabbits
    Park, Chang Hyun
    Lee, Hyun Soo
    Chung, Sung Kun
    CORNEA, 2014, 33 (09) : 928 - 934
  • [47] Toxicity of Intrastromal Voriconazole Injection on Corneal Endothelium in Rabbits
    Lim, Byung Su
    Park, Chang Hyun
    Chung, Sung Kun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [48] Correction of hyperopia by intrastromal cutting and liquid filler injection
    Freidank, Sebastian
    Vogel, Alfred
    Anderson, R. Rox
    Birngruber, Reginald
    Linz, Norbert
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (05)
  • [49] COLLAGEL - A NEW VISCOELASTIC SUBSTANCE FOR OPHTHALMIC SURGERY
    BLECKMANN, H
    VOGT, R
    GARUS, HJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01): : 20 - 26
  • [50] Viscoelastic interactions between polydeoxyribonucleotide and ophthalmic excipients
    Kim, Iksoo
    Kim, Hyeongmin
    Park, Kyunghee
    Karki, Sandeep
    Khadka, Prakash
    Jo, Kanghee
    Kim, Seong Yeon
    Ro, Jieun
    Lee, Jaehwi