Laminate fibre structure characterisation of carbon fibre-reinforced polymers by X-ray scatter dark field imaging with a grating interferometer

被引:71
作者
Revol, Vincent [1 ]
Plank, Bernhard [2 ]
Kaufmann, Rolf [1 ]
Kastner, Johann [2 ]
Kottler, Christian [1 ]
Neels, Antonia [3 ]
机构
[1] Ctr Suisse Elect & Microtech, CH-8005 Zurich, Switzerland
[2] Univ Appl Sci Upper Austria, A-4600 Wels, Austria
[3] Ctr Suisse Elect & Microtech, CH-2002 Neuchatel, Switzerland
关键词
X-ray phase contrast imaging; X-ray grating interferometer; Fibre-reinforced Polymers; COMPUTED-TOMOGRAPHY; NONDESTRUCTIVE EVALUATION; TALBOT INTERFEROMETRY; CONTRAST; COMPOSITES;
D O I
10.1016/j.ndteint.2013.04.012
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray scatter dark field imaging (SDFI) using a Talbot-Lau grating interferometer has recently attracted growing interest for the non-destructive testing and evaluation of light materials. In this work, we developed the method further for the characterisation of the laminate structure of carbon fibre reinforced polymers. In particular, we used the anisotropic properties of the small angle scattering signal to image the fibre bundles running in different directions independently with excellent contrast. The results obtained for four different woven carbon fibre reinforced polymer samples were compared to high resolution X-ray computed tomography results. We found that SDFI allows for the visualisation of the weave pattern structure and analysis of the size of the carbon fibre bundle in three dimensions, even if the individual fibres cannot be separated or the absorption contrast between the carbon fibres and the epoxy matrix is very low. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 31 条
[1]   Quantitative x-ray dark-field computed tomography [J].
Bech, M. ;
Bunk, O. ;
Donath, T. ;
Feidenhans'l, R. ;
David, C. ;
Pfeiffer, F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) :5529-5539
[2]  
Bossi, 2005, AM I PHYS C P, V820, P965
[3]   Fabrication of diffraction gratings for hard X-ray phase contrast imaging [J].
David, C. ;
Bruder, J. ;
Rohbeck, T. ;
Gruenzweig, C. ;
Kottler, C. ;
Diaz, A. ;
Bunk, O. ;
Pfeiffer, F. .
MICROELECTRONIC ENGINEERING, 2007, 84 (5-8) :1172-1177
[4]   Differential x-ray phase contrast imaging using a shearing interferometer [J].
David, C ;
Nöhammer, B ;
Solak, HH ;
Ziegler, E .
APPLIED PHYSICS LETTERS, 2002, 81 (17) :3287-3289
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]   X-RAY INTERACTIONS - PHOTOABSORPTION, SCATTERING, TRANSMISSION, AND REFLECTION AT E=50-30,000 EV, Z=1-92 [J].
HENKE, BL ;
GULLIKSON, EM ;
DAVIS, JC .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1993, 54 (02) :181-342
[7]   NONDESTRUCTIVE EVALUATION OF SINGLE-FIBER DEBONDING IN COMPOSITES BY X-RAY REFRACTION [J].
HENTSCHEL, MP ;
HARBICH, KW ;
LANGE, A .
NDT & E INTERNATIONAL, 1994, 27 (05) :275-280
[8]   Directional x-ray dark-field imaging [J].
Jensen, Torben H. ;
Bech, Martin ;
Bunk, Oliver ;
Donath, Tilman ;
David, Christian ;
Feidenhans'i, Robert ;
Pfeiffer, Franz .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12) :3317-3323
[9]   Reduction of phase artifacts in differential phase contrast computed tomography [J].
Jerjen, Iwan ;
Revol, Vincent ;
Schuetz, Philipp ;
Kottler, Christian ;
Kaufmann, Rolf ;
Luethi, Thomas ;
Jefimovs, Konstantins ;
Urban, Claus ;
Sennhauser, Urs .
OPTICS EXPRESS, 2011, 19 (14) :13604-13611
[10]  
Kastner J, 2012, P WORLD C NOND TEST