Multicenter Spanish study of spectral-domain optical coherence tomography in normal children

被引:88
作者
Barrio-Barrio, Jesus [1 ]
Noval, Susana [2 ]
Galdos, Marta [3 ,4 ]
Ruiz-Canela, Miguel [5 ]
Bonet, Elvira [1 ]
Capote, Maria [2 ]
Lopez, Maialen [3 ]
机构
[1] Univ Navarra, Clin Univ Navarra, Dept Ophthalmol, Pamplona 31008, Spain
[2] Autonomous Univ Madrid, IdiPaz, Hosp Univ La Paz, E-28049 Madrid, Spain
[3] Hosp Cruces, Dept Ophthalmol, Bilbao, Spain
[4] ICQO, Bilbao, Spain
[5] Univ Navarra Pamplona, Dept Biomed Humanities, Pamplona, Spain
关键词
database; macular thickness; optical coherence tomography; retinal nerve fibre layer; RETINAL NERVE-FIBER; MACULAR THICKNESS MEASUREMENTS; LAYER THICKNESS; TIME-DOMAIN; STRATUS OCT; EYES; POPULATION; CIRRUS; HEALTHY; REPRODUCIBILITY;
D O I
10.1111/j.1755-3768.2012.02562.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
. Purpose: To compile a multicenter normative database of retinal nerve fibre layer (RNFL) and macular thicknesses and macular volume values in healthy Caucasian children 417 years using spectral-domain optical coherence tomography (SD-OCT). To analyse variations in the OCT measurements as a function of age, sex, refraction, and axial length (AL). Methods: An observational, multicenter and cross-sectional study among 301 healthy Caucasian children recruited at three Spanish centres was performed. To compile the database, each child underwent a dilated eye examination and a cycloplegic refraction, five AL measurements (IOL Master; Carl Zeiss Meditec, Dublin, CA, USA), five OCT scans with Cirrus OCT: three peripapillary RNFL scans (Optic Disc Cube 200X200 protocol) and two macular scans (Macular Cube 512X128 protocol). One eye of each subject was selected randomly for analysis. Results: Two hundred eighty-three children (117 boys, 41.34%; 166 girls, 58.66%) were included in this study. The mean age of the children was 9.58 +/- 3.12 years (range, 417). The mean SE was +0.63 +/- 1.65 D; (range, -4.88 to +5.25). The mean AL was 22.94 +/- 1.10 mm (range, 20.1026.27). The mean global RNFL thickness was 97.40 +/- 9.0 mu m (range, 77121.7 mu m). Multivariate analysis showed a positive correlation between the RNFL and spherical equivalent (SE) (p = 0.014). The mean central macular thickness was 253.85 +/- 19.76 mu m, the average thickness 283.62 +/- 14.08 mu m, and the mean macular volume 10.22 +/- 0.49 mu m3. Multivariate analysis showed a positive correlation between central macular thickness and age (p < 0.001). Boys had a significantly thicker central macula than girls (p < 0.001). Conclusions: Normative paediatric SD-OCT data might facilitate use of SD-OCT for assessing childhood ophthalmic diseases. This study provides a multicenter paediatric normative database of SD-OCT peripapillary RNFL and macular data.
引用
收藏
页码:e56 / e63
页数:8
相关论文
共 40 条
[1]   Transitioning from stratus OCT to cirrus OCT: a comparison and a proposed equation to convert central subfield macular thickness measurements in healthy subjects [J].
Abedi, Gelareh ;
Patal, Payal ;
Doros, Gheorghe ;
Subramanian, Manju L. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) :1353-1357
[2]  
Ahn Han-Cheul, 2005, Korean J Ophthalmol, V19, P195
[3]   Performance of time-domain and spectral-domain Optical Coherence Tomography for glaucoma screening [J].
Bengtsson, Boel ;
Andersson, Sabina ;
Heijl, Anders .
ACTA OPHTHALMOLOGICA, 2012, 90 (04) :310-315
[4]   Optical Coherence Tomography in the Eyes of Normal Children [J].
El-Dairi, Mays A. ;
Asrani, Sanjay G. ;
Enyedi, Laura B. ;
Freedman, Sharon F. .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (01) :50-58
[5]   Normal reference ranges of optical coherence tomography parameters in childhood [J].
Elia, Noemi ;
Pueyo, Victoria ;
Altemir, Irene ;
Oros, Daniel ;
Emilio Pablo, Luis .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (05) :665-670
[6]   Is quantitative spectral-domain superior to time-domain optical coherence tomography (OCT) in eyes with age-related macular degeneration? [J].
Eriksson, Urban ;
Alm, Albert ;
Larsson, Eva .
ACTA OPHTHALMOLOGICA, 2012, 90 (07) :620-627
[7]   A population-based study of macular thickness in full-term children assessed with Stratus OCT: normative data and repeatability [J].
Eriksson, Urban ;
Holmstrom, Gerd ;
Alm, Albert ;
Larsson, Eva .
ACTA OPHTHALMOLOGICA, 2009, 87 (07) :741-745
[8]   Intra and interoperator reproducibility of retinal nerve fibre and macular thickness measurements using Cirrus Fourier-domain OCT [J].
Garcia-Martin, Elena ;
Pinilla, Isabel ;
Idoipe, Miriam ;
Fuertes, Isabel ;
Pueyo, Victoria .
ACTA OPHTHALMOLOGICA, 2011, 89 (01) :E23-E29
[9]   Retinal nerve fiber layer in OCT 3: Prospective study of 53 normal children [J].
Gire, J. ;
Cornand, E. ;
Fogliarini, C. ;
Benso, C. ;
Haouchine, B. ;
Denis, D. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2010, 33 (07) :444-449
[10]   REPRODUCIBILITY AND COMPARISON OF RETINAL THICKNESS AND VOLUME MEASUREMENTS IN NORMAL EYES DETERMINED WITH TWO DIFFERENT CIRRUS OCT SCANNING PROTOCOLS [J].
Hagen, Stefan ;
Krebs, Ilse ;
Haas, Paulina ;
Glittenberg, Carl ;
Falkner-Radler, Christiane I. ;
Graf, Alexandra ;
Ansari-Shahrezaei, Siamak ;
Binder, Susanne .