Optimization of the single-step synthesis of hybrid C8 silica monoliths dedicated to nano-liquid chromatography and capillary electrochromatography

被引:21
作者
Roux, R. [1 ]
Jaoude, M. Abi [1 ]
Demesmay, C. [1 ]
Rocca, J. -L. [1 ]
机构
[1] Univ Lyon 1, Sci Analyt Lab, UMR 5180, F-69622 Villeurbanne, France
关键词
Hybrid silica monoliths; Nano-liquid chromatography; Capillary electrochromatography;
D O I
10.1016/j.chroma.2008.08.119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hybrid silica monoliths functionalized with octyl groups and dedicated to chromatographic separations in the reversed-phase mode were directly synthesized within capillaries according to the protocol described by Yan et al. [L.J. Yan, Q.H. Zhang, Y.Q. Feng, W.B. Zhang, T. Li, L.H. Zhang, Y.X Zhang.J. Chromatogr. A 1121 (2006) 92]. Although these monoliths allowed reaching high efficiencies in capillary electrochromatography (CEC), serious limitations prohibited their application in nano-liquid chromatography (nano-LC). Such limitations observed as poor performances in the nano-LC mode and the lack of reproducibility of the synthesis were related to the longitudinal morphological inhomogeneities of the hybrid material along the capillary. Thus, several modifications were conducted in the synthesis protocol in order to improve the resulting morphology of the monolith making it suitable for nano-LC separations. The influence of several critical parameters (such as the addition temperature of the basic catalyst and the hydrolysis duration) on the textural and chromatographic properties had been extensively studied. It was found that a decrease (i.e. 0 degrees C) of the temperature addition of the basic catalyst associated with a shorter hydrolysis duration (1 h instead of 6h) allowed (i) delaying the gelation time and consequently facilitating the capillary filling step, (ii) increasing the structural homogeneity of the hybrid monoliths, i.e. their chromatographic performances in nano-liquid chromatography also (iii) greatly improving the reproducibility of the synthesis within the capillary without impairing the material's carbon load, i.e. the incorporation of the less hydrolysable C-8 precursor. The resulting hybrid monoliths afforded retention factors comparable to that previously obtained for C-18 grafted silica monoliths and efficiencies that are the best ever recorded in nano-LC with hybrid monoliths and that are close to the ones achieved with grafted silica monoliths. In fact, this modified protocol allowed a significant improvement of the performances in nano-LC which could be observed by the decrease of the mean value of H-min going from 123 mu m (Yan's protocol) to 24 mu m (modified protocol) for a same length of capillary (l = 8.5 cm). In addition, the reproducibility of the synthesis was greatly improved through a factor six of reduction on the calculated standard deviation of these efficiencies. The high permeability and longitudinal homogeneity of the synthesized monolith allowed increasing the capillary length (for example, a 75-cm capillary was conveniently filled with hybrid silica monolith) and the column could be eluted at a very low backpressure leading to chromatographic performances up to 40,000 plates. Finally, the good efficiencies in the nano-LC mode combined with the excellent performances already present in the CEC mode led to fast (less than 1 min) and high efficient separations in the pressurized capillary electrochromatography (p-CEC) mode. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:120 / 127
页数:8
相关论文
共 43 条
[1]   ELECTROPHORETIC SEPARATIONS OF PROTEINS IN CAPILLARIES WITH HYDROLYTICALLY STABLE SURFACE-STRUCTURES [J].
COBB, KA ;
DOLNIK, V ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1990, 62 (22) :2478-2483
[2]   Allyl-functionalized hybrid silica monoliths [J].
Colón, H ;
Zhang, X ;
Murphy, JK ;
Rivera, JG ;
Colón, LA .
CHEMICAL COMMUNICATIONS, 2005, (22) :2826-2828
[3]   Performance limits of monolithic and packed capillary columns in high-performance liquid chromatography and capillary electrochromatography [J].
Eeltink, S ;
Desmet, G ;
Vivó-Truyols, G ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1104 (1-2) :256-262
[4]   Optimization of the porous structure and polarity of polymethacrylate-based monolithic capillary columns for the LC-MS separation of enzymatic digests [J].
Eeltink, Sebastiaan ;
Geiser, Laurent ;
Svec, Frantisek ;
Frechet, Jean M. J. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (17) :2814-2820
[5]  
Fujimoto C, 2000, HRC-J HIGH RES CHROM, V23, P89
[6]   Microchip-based CEC of nitroaromatic and nitramine explosives using silica-based sol-gel stationary phases from methyl- and ethyl-trimethoxysilane precursors [J].
Giordano, Braden C. ;
Terray, Alex ;
Collins, Greg E. .
ELECTROPHORESIS, 2006, 27 (21) :4295-4302
[7]   Monolithic columns in high-performance liquid chromatography [J].
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) :101-168
[8]   Performance of monolithic silica capillary columns with increased phase ratios and small-sized domains [J].
Hara, Takeshi ;
Kobayashi, Hiroshi ;
Ikegami, Tohru ;
Nakanishi, Kazuki ;
Tanaka, Nobuo .
ANALYTICAL CHEMISTRY, 2006, 78 (22) :7632-7642
[9]   Sol-gel monolithic columns with reversed electroosmotic flow for capillary electrochromatography [J].
Hayes, JD ;
Malik, A .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :4090-4099
[10]   Highly efficient monolithic silica capillary columns modified with poly(acrylic acid) for hydrophilic interaction chromatography [J].
Horie, Kanta ;
Ikegami, Tohru ;
Hosoya, Ken ;
Saad, Nabil ;
Fiehn, Oliver ;
Tanaka, Nobuo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) :198-205