High-Frame-Rate Speckle-Tracking Echocardiography

被引:50
作者
Joos, Philippe [1 ]
Poree, Jonathan [2 ]
Liebgott, Herve [1 ]
Vray, Didier [1 ]
Baudet, Mathilde [3 ]
Faurie, Julia [2 ]
Tournoux, Francois [3 ]
Cloutier, Guy [2 ,4 ]
Nicolas, Barbara [1 ]
Garcia, Damien [1 ,4 ,5 ]
机构
[1] Univ Claude Bernard Lyon 1, Univ Lyon, CNRS,UMR 5220, INSERM,INSA Lyon,CREATIS,UJM St Etienne,U1206, F-69361 Lyon, France
[2] Univ Montreal, Hosp Res Ctr, Lab Biorheol & Med Ultrason, Montreal, PQ, Canada
[3] Univ Montreal Hosp, Echocardiog Lab, Montreal, PQ H2W 1T8, Canada
[4] Univ Montreal, Inst Biomed Engn, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[5] Univ Montreal Hosp, Res Ctr, Montreal, PQ H2X 0A9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cardiac imaging; diverging waves; high-frame-rate echocardiography; motion compensation (MoCo); speckle-tracking echocardiography (STE); ultrafast ultrasound; GLOBAL LONGITUDINAL STRAIN; IN-VIVO; OPTICAL-FLOW; TRANSVERSE OSCILLATIONS; ULTRAFAST ULTRASOUND; MOTION-COMPENSATION; PHASE CORRELATION; CARDIAC MOTION; PEAK-LOCKING; METAANALYSIS;
D O I
10.1109/TUFFC.2018.2809553
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional echocardiography is the leading modality for noninvasive cardiac imaging. It has been recently illustrated that high-frame-rate echocardiography using diverging waves could improve cardiac assessment. The spatial resolution and contrast associated with this method are commonly improved by coherent compounding of steered beams. However, owing to fast tissue velocities in the myocardium, the summation process of successive diverging waves can lead to destructive interferences if motion compensation (MoCo) is not considered. Coherent compounding methods based on MoCo have demonstrated their potential to provide high-contrast B-mode cardiac images. Ultrafast speckle-tracking echocardiography (STE) based on common speckle-tracking algorithms could substantially benefit from this original approach. In this paper, we applied STE on high-frame-rate B-mode images obtained with a specific MoCo technique to quantify the 2-D motion and tissue velocities of the left ventricle. The method was first validated in vitro and then evaluated in vivo in the four-chamber view of 10 volunteers. High-contrast high-resolution B-mode images were constructed at 500 frames/s. The sequences were generated with a Verasonics scanner and a 2.5-MHz phased array. The 2-D motion was estimated with standard cross correlation combined with three different subpixel adjustment techniques. The estimated in vitro velocity vectors derived from STE were consistent with the expected values, with normalized errors ranging from 4% to 12% in the radial direction and from 10% to 20% in the cross-range direction. Global longitudinal strain of the left ventricle was also obtained from STE in 10 subjects and compared to the results provided by a clinical scanner: group means were not statistically different (p value = 0.33). The in vitro and in vivo results showed that MoCo enables preservation of the myocardial speckles and in turn allows high-frame-rate STE.
引用
收藏
页码:720 / 728
页数:9
相关论文
共 49 条
[1]  
Addetia Karima, 2016, Circ Cardiovasc Imaging, V9, pe003895, DOI 10.1161/CIRCIMAGING.115.003895
[2]   A New Technique for the Estimation of Cardiac Motion in Echocardiography Based on Transverse Oscillations: A Preliminary Evaluation In Silico and a Feasibility Demonstration In Vivo [J].
Alessandrini, Martino ;
Basarab, Adrian ;
Boussel, Loic ;
Guo, Xinxin ;
Serusclat, Andre ;
Friboulet, Denis ;
Kouame, Denis ;
Bernard, Olivier ;
Liebgott, Herve .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) :1148-1162
[3]   HIGH-FRAME-RATE DEFORMATION IMAGING IN TWO DIMENSIONS USING CONTINUOUS SPECKLE-FEATURE TRACKING [J].
Andersen, Martin V. ;
Moore, Cooper ;
Arges, Kristine ;
Sogaard, Peter ;
Ostergaard, Lasse R. ;
Schmidt, Samuel E. ;
Kisslo, Joseph ;
Von Ramm, Olaf T. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (11) :2606-2615
[4]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[5]   Pulsed Doppler tissue imaging in endurance athletes: Relation between left ventricular preload and myocardial regional diastolic function [J].
Caso, P ;
D'Andrea, A ;
Galderisi, M ;
Liccardo, B ;
Severino, S ;
De Simone, L ;
Izzo, A ;
D'Andrea, L ;
Mininni, N .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (09) :1131-1136
[6]   Feasibility of Multiplane-Transmit Beamforming for Real-Time Volumetric Cardiac Imaging: A Simulation Study [J].
Chen, Yinran ;
Tong, Ling ;
Ortega, Alejandra ;
Luo, Jianwen ;
D'hooge, Jan .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (04) :648-659
[7]   Modeling and correction of peak-locking in digital PIV [J].
Cholemari, Murali R. .
EXPERIMENTS IN FLUIDS, 2007, 42 (06) :913-922
[8]  
Christensen KT, 2004, EXP FLUIDS, V36, P484, DOI 10.1007/S00348-003-0754-2
[9]   3-D Imaging Using Row-Column-Addressed Arrays With Integrated Apodization-Part II: Transducer Fabrication and Experimental Results [J].
Christiansen, Thomas Lehrmann ;
Rasmussen, Morten Fischer ;
Bagge, Jan Peter ;
Moesner, Lars Nordahl ;
Jensen, Jorgen Arendt ;
Thomsen, Erik Vilain .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) :959-971
[10]   Ultrafast Cardiac Ultrasound Imaging Technical Principles, Applications, and Clinical Benefits [J].
Cikes, Maja ;
Tong, Ling ;
Sutherland, George R. ;
D'hooge, Jan .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (08) :812-823