Intrastromal corneal ring segments for management of keratoconus

被引:22
作者
Ganesh, Sri [1 ]
Shetty, Rohit [2 ]
D'Souza, Sharon [2 ]
Ramachandran, Sarika [2 ]
Kurian, Mathew [2 ]
机构
[1] Narayana Nethralaya, Superspecial Eye Inst, Dept Refract Surg, Bangalore 560010, Karnataka, India
[2] Nethradhama Superspecial Eye Hosp, Dept Phacorefract Surg, Bangalore, Karnataka, India
关键词
Intrastromal corneal rings segments; keratoconus; treatment; TERM-FOLLOW-UP; FEMTOSECOND LASER; INTACS IMPLANTATION; REFRACTIVE SURGERY; COMPLICATIONS; KERATOPLASTY; EFFICACY;
D O I
10.4103/0301-4738.116065
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Keratoconus is a progressive corneal ectasia, which can be managed both by conservative measures like glasses or contact lenses in non-progressive cases or surgical procedures like collagen crosslinking (CXL) with or without adjuvant measures like intrastromal corneal rings segments (ICRS) or topography guided ablation. Various kinds of ICRS are available to the surgeon, but it is most essential to be able to plan the implantation of the ring to optimize outcomes. Aims: The aim of this study is to evaluate the visual outcome and progression in patients of keratoconus implanted with ICRS. Materials and Methods: Two different types of ICRS-Intacs (Addition Technology) and Kerarings (Mediphacos Inc.) were implanted in 2 different cohorts of patients and were followed-up to evaluate the outcome of the procedure. All patients underwent a complete ocular examination including best spectacle corrected visual acuity, slit lamp examination fundus examination, corneal topography and pachymetry. The ICRS implantation is done with CXL to stop the progression of the disease. Improvement in uncorrected visual acuity (UCVA), best spectacle corrected visual acuity and topographic changes were analyzed. Results: A significant improvement in keratometry and vision was seen in both groups. Conclusion: ICRS have been found to reduce corneal irregularity and flatten keratometry with improvement in UCVA and best corrected visual acuity.
引用
收藏
页码:451 / 455
页数:5
相关论文
共 27 条
[1]   Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction [J].
Alió, JL ;
Shabayek, MH ;
Belda, JI ;
Correas, P ;
Feijoo, ED .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :756-761
[2]  
Barraquer J I, 1966, Int Ophthalmol Clin, V6, P53, DOI 10.1097/00004397-196606010-00004
[3]  
Buratto L, 1998, J REFRACT SURG, V14, P517
[4]  
Burris T E, 1991, Refract Corneal Surg, V7, P46
[5]   Effect of inferior-segment Intacs with and without C3-R on keratoconus [J].
Chan, Colin C. K. ;
Sharma, Munish ;
Wachler, Brian S. Boxer .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :75-80
[6]   European clinical evaluation: Use of Intacs for the treatment of keratoconus [J].
Colin, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :747-755
[7]   INTACS inserts for treating keratoconus - One-year results [J].
Colin, J ;
Cochener, B ;
Savary, G ;
Malet, F ;
Holmes-Higgin, D .
OPHTHALMOLOGY, 2001, 108 (08) :1409-1414
[8]   One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus [J].
Coskunseven, Efekan ;
Kymionis, George D. ;
Tsiklis, Nikolaos S. ;
Atun, Serife ;
Arslan, Ebru ;
Jankov, Mirko R. ;
Pallikaris, Ioannis G. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (05) :775-779
[9]   Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus [J].
Dauwe, Caroline ;
Touboul, David ;
Roberts, Cynthia J. ;
Mahmoud, Ashraf M. ;
Kerautret, Julien ;
Fournier, Pierre ;
Malecaze, Francois ;
Colin, Joseph .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10) :1761-1767
[10]   Intacs implantation using a femtosecond laser for management of keratoconus: Comparison of 306 cases in different stages [J].
Ertan, Aylin ;
Kamburoglu, Guenhal .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1521-1526