Wide-view charge exchange recombination spectroscopy diagnostic for Alcator C-Mod

被引:8
作者
Rowan, W. L. [1 ]
Bespamyatnov, I. O. [1 ]
Granetz, R. S. [2 ]
机构
[1] Univ Texas Austin, Fus Res Ctr, Austin, TX 78712 USA
[2] MIT, Plasma Sci & Fus Ctr, Cambridge, MA 02139 USA
关键词
plasma density; plasma diagnostics; plasma flow; plasma impurities; plasma temperature; plasma toroidal confinement; plasma transport processes; Tokamak devices;
D O I
10.1063/1.2979865
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This diagnostic measures temperature, density, and rotation for the fully stripped boron ion between the pedestal top and the plasma core with resolution consistent with the profile gradients. The diagnostic neutral beam used for the measurements generates a 50 keV, 6 A hydrogen beam. The optical systems provide views in both poloidal and toroidal directions. The imaging spectrometer is optimized to simultaneously accept 45 views as input with minimum cross-talk. In situ calibration techniques are applied for spatial location, spectral intensity, and wavelength. In the analysis, measured spectra are fitted to a model constructed from a detailed description of the emission physics. Methods for removal of interfering spectra are included. Applications include impurity and thermal transport.
引用
收藏
页数:4
相关论文
共 8 条
[1]  
BEALS DF, 2005, P 21 IEEE NPSS S FUS, P558
[2]   Tokamak fusion test reactor poloidal rotation diagnostic (invited) [J].
Bell, RE ;
Dudek, LE ;
Grek, B ;
Johnson, DW ;
Palladino, RW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :821-826
[3]   Effects of neutral-beam excited states on charge-exchange emission cross sections [J].
Bespamyatnov, I. O. ;
Rowan, W. L. ;
Granetz, R. S. ;
Beals, D. F. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10)
[4]   Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis [J].
Bespamyatnov, Igor O. ;
Rowan, William L. ;
Granetz, Robert S. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
[5]   Parametrization of the Zeeman effect for hydrogen-like spectra in high-temperature plasmas [J].
Blom, A ;
Jupén, C .
PLASMA PHYSICS AND CONTROLLED FUSION, 2002, 44 (07) :1229-1241
[6]   Neutral beam injector for active plasma spectroscopy [J].
Korepanov, SA ;
Abdrashitov, GF ;
Beals, D ;
Davydenko, VI ;
Deichuli, PP ;
Granetz, R ;
Ivanov, AA ;
Kolmogorov, VV ;
Mishagin, VV ;
Puiatti, M ;
Rowan, B ;
Stupishin, NV ;
Shulzhenko, GI ;
Valisa, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05) :1829-1831
[7]   MDSsplus data acquisition system [J].
Stillerman, JA ;
Fredian, TW ;
Klare, KA ;
Manduchi, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :939-942
[8]  
Summers H., 2004, Atomic data and analysis structure users manual 2.6