Effect of Radial Cooling Ducts on the Electromagnetic Performance of the Permanent Magnet Synchronous Generators With Double Radial Forced Air Cooling for Direct-Driven Wind Turbines

被引:39
作者
Ruuskanen, Vesa [1 ]
Nerg, Janne [1 ]
Niemela, Markku [1 ]
Pyrhonen, Juha [1 ]
Polinder, Henk [2 ]
机构
[1] LUT Energy, Lappeenranta 53851, Finland
[2] Delft Univ Technol, Dept Elect Sustainable Energy, NL-2628 CD Delft, Netherlands
基金
芬兰科学院;
关键词
Cooling; permanent magnet generators; permanent magnet machines; thermal analysis; wind power generation; MACHINES;
D O I
10.1109/TMAG.2013.2238679
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most of the high-power, low-speed, direct-driven permanent magnet synchronous generators for wind energy applications apply a cooling solution where the stator core is divided into a number of substacks. Cooling air is blown through the stator through radial cooling channels formed between the adjacent stator substacks. The use of the stator substacks has an effect on the equivalent length of the generator, and thus, if neglected, leads to an incorrect no-load voltage and synchronous inductance calculation. In this paper, the design issues related to the thermal and electromagnetic design of permanent magnet synchronous machines are highlighted. The analysis starts with a preliminary electromagnetic design. Then, the allowable number and width of cooling ducts are calculated based on the maximum allowable temperatures and fluid flow speed with a thermal resistance network model. The effect of cooling ducts on the no-load voltage and synchronous inductances of the machine are discussed in detail. The calculated no-load voltage and synchronous inductances are used in the analytical performance evaluation. It is shown that the cross-saturation of the synchronous inductances must be taken into account in order to get realistic results.
引用
收藏
页码:2974 / 2981
页数:8
相关论文
共 20 条
[1]  
[Anonymous], THESIS LAPPEENRANTA
[2]  
Bang D., 2007, P EUR WIND EN C EXH
[3]  
Carter F., 1901, Elect. World Engineer, V38, P884
[4]   Analytical Design Model for Surface-Mounted Permanent-Magnet Synchronous Machines [J].
Cassimere, Brandon N. ;
Sudhoff, Scott D. ;
Sudhoff, Doug H. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (02) :347-357
[5]   Air cooling for a large-scale motor [J].
Chang, Chih-Chung ;
Kuo, Yu-Fu ;
Wang, Jung-Chang ;
Chen, Sih-Li .
APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) :1360-1368
[6]   Force density limits in low-speed PM machines due to temperature and reactance [J].
Grauers, A ;
Kasinathan, P .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (03) :518-525
[7]   Overview of different wind generator systems and their comparisons [J].
Li, H. ;
Chen, Z. .
IET RENEWABLE POWER GENERATION, 2008, 2 (02) :123-138
[8]  
Nerg J., 2012, MATH C IN PRESS 0919
[9]  
Nerg J., 2011, P ELECTR 11 CERG PON
[10]   Thermal Analysis of Radial-Flux Electrical Machines With a High Power Density [J].
Nerg, Janne ;
Rilla, Marko ;
Pyrhonen, Juha .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (10) :3543-3554