Liquid chromatography-electrospray tandem mass spectrometric assay suitable for quantitation of YM155, a novel small-molecule survivin suppressant, in dog plasma

被引:8
|
作者
Minematsu, Tsuyoshi [1 ]
Felder, Laurie [2 ]
Oppeneer, Todd [2 ]
Sakazume, Masashi [3 ]
Oikawa, Keishi [4 ]
Hashimoto, Tadashi [1 ]
Usui, Takashi [1 ]
Kamimura, Hidetaka [1 ]
机构
[1] Astellas Pharma Inc, Drug Metab Res Labs, Itabashi Ku, Tokyo 1748511, Japan
[2] Covance Labs Inc, Madison, WI USA
[3] Astellas Res Technol Co Ltd, Tokyo, Japan
[4] Astellas Pharma Inc, Clin Pharmacol, Tokyo, Japan
关键词
YM155; bioanalytical method; LC-MS/MS; validation; pharmacokinetics; dog plasma;
D O I
10.1002/bmc.996
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a sensitive and selective liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for determination of the novel survivin suppressant YM155, 1-(2-methoxyethyl)-2-methyl-4,9-dioxo-3-(pyrazin-2-ylmethyl)-4,9-dihydro-1H-naphtho[2,3-d]imidazolium, which is developed for the treatment of solid tumors. This method uses a liquid-liquid extraction from 0.25 mL of dog plasma. LC separation was carried out on a Genesis Silica column (50 mm x 3.0 mm i.d.) at a flow-rate of 0.5 mL/min. Compounds were eluted using a mobile phase of 5 mm ammonium acetate and 0.1% formic acid in water-0.1% formic acid in acetonitrile, 17:83 (v/v). MS/MS detection was carried out with an MDS-Sciex API3000 triple quadrupole mass spectrometer in positive electrospray ionization mode. The standard curve was linear from 0.05 to 50 ng/mL (r >= 0.9968). The lower limit of quantitation was 0.05 ng/mL. Good intra- and inter-day assay precision (within 7.4% RSD) and accuracy (within +/- 12.3%) were obtained. The extraction recovery was 66.2%. The method was successfully applied to preelinical pharmacokinetic studies in dogs. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:763 / 769
页数:7
相关论文
共 50 条
  • [31] Quantitation of tryptophan, kynurenine and kynurenic acid in human plasma by capillary liquid chromatography-electrospray ionization tandem mass spectrometry
    Amirkhani, A
    Heldin, E
    Markides, KE
    Bergquist, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 381 - 387
  • [32] Quantitation of camellianin A in HepG2 cells using a high performance liquid chromatography-electrospray ionization tandem mass spectrometric method
    Chen Qian-Qian
    Xi Hai-Ling
    Wang Cai-Yun
    Xu Feng-Guo
    Zhang Wei
    CHINESE JOURNAL OF NATURAL MEDICINES, 2017, 15 (03) : 234 - 240
  • [33] Quantitation of camellianin A in HepG2 cells using a high performance liquid chromatography-electrospray ionization tandem mass spectrometric method
    CHEN Qian-Qian
    XI Hai-Ling
    WANG Cai-Yun
    XU Feng-Guo
    ZHANG Wei
    Chinese Journal of Natural Medicines, 2017, 15 (03) : 234 - 240
  • [34] A flexible and high throughput liquid chromatography-tandem mass spectrometric assay for the quantitation of telcagepant in human plasma
    Du, Lihong
    Miller-Stein, Cynthia M.
    Valesky, Robert J.
    Martucci, Ashley N.
    Woolf, Eric J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15): : 1465 - 1471
  • [35] Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study
    BAI Jing 1
    2.Department of Pharmacy
    Chemical Research in Chinese Universities, 2012, 28 (03) : 399 - 405
  • [36] Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study
    Bai Jing
    Shi Xiao-wei
    Du Ying-feng
    Xiang Bai
    Wang Shuai
    Cao De-ying
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (03) : 399 - 405
  • [37] Liquid chromatography-tandem mass spectrometric assay with a novel method of quantitation for the simultaneous determination of bulaquine and its metabolite, primaquine, in monkey plasma
    Nitin, M
    Rajanikanth, M
    Lal, J
    Madhusudanan, KP
    Gupta, RC
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (02): : 253 - 263
  • [38] Liquid chromatography-electrospray ionization-tandem mass spectrometric assay for d-aspartate N-methyltransferase activity in ark shells
    Shibata, Kimihiko
    Hagiya, Saho
    Okawara, Rena
    Abe, Katsumasa
    Takahashi, Shouji
    Kera, Yoshio
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2020, 84 (03) : 500 - 506
  • [39] Measurement of mycophenolic acid and its glucuronide using a novel rapid liquid chromatography-electrospray ionization tandem mass spectrometry assay
    Kuhn, Joachim
    Prante, Christian
    Kleesiek, Knut
    Goetting, Christian
    CLINICAL BIOCHEMISTRY, 2009, 42 (1-2) : 83 - 90
  • [40] Utility of P-Glycoprotein and Organic Cation Transporter 1 Double-Transfected LLC-PK1 Cells for Studying the Interaction of YM155 Monobromide, Novel Small-Molecule Survivin Suppressant, with P-Glycoprotein
    Iwai, Megumi
    Minematsu, Tsuyoshi
    Li, Qun
    Iwatsubo, Takafumi
    Usui, Takashi
    DRUG METABOLISM AND DISPOSITION, 2011, 39 (12) : 2314 - 2320