A Biomechanical Evaluation of a Hybrid Dynamic Compression Plate and a CastLess Arthrodesis Plate for Pancarpal Arthrodesis in Dogs

被引:11
作者
Meeson, Richard L. [1 ]
Goodship, Allen E. [2 ,3 ]
Arthurs, Gareth I. [1 ]
机构
[1] Univ London, Royal Vet Coll, Dept Vet Clin Sci, Hatfield AL9 7TA, Herts, England
[2] UCL, Royal Vet Coll, Dept Vet Basic Sci, London WC1E 6BT, England
[3] UCL, Inst Orthopaed, London WC1E 6BT, England
关键词
CLINICAL-EVALUATION; FRACTURES; FIXATION; CARPAL;
D O I
10.1111/j.1532-950X.2012.00985.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To determine mechanical differences between two plates with different requirements for supplementary casting after pancarpal arthrodesis (PCA): the Veterinary Instrumentation Hybrid Dynamic Compression Plate (HDCP), and the OrthoMed CastLess Arthrodesis Plate (CLP). Study Design In vitro mechanical analysis. Sample Population HDCP(n = 10), CLP(10). Methods Single-cycle load to failure using a materials-testing machine and cyclic loading between 38 and 380 N +/- 5% to simulate estimated in vivo loads until failure or 106 cycles. Results Single-cycle to failure: bending stiffness was significantly higher for the HDCP(2269 +/- 175 N/mm) than CLP(1754 +/- 88 N/mm; P < .001). Bending structural stiffness was higher for the HDCP(3.8 +/- 0.3 Nm2) versus CLP(2.9 +/- 0.2 Nm2; P= .0022). A difference between the 2 plates for bending strength was not demonstrated; HDCP= 13.9 +/- 1.4 Nm, CLP13.2 +/- 0.5 Nm (P= .24). Cyclic Loading: no failures occurred with either plate type when plates were cycled to 106 cycles. Conclusion There is no mechanical advantage in bending resistance afforded by the CLPover the HDCP. Fatigue failure of either plate during the convalescent period of an estimated 150,000250,000 cycles is unlikely. Based on the bending performance, there is no evidence to support the use of the CLPover the HDCPfor castless PCA.
引用
收藏
页码:738 / 744
页数:7
相关论文
共 27 条
[1]   Ground reaction force profiles after partial and pancarpal arthrodesis in dogs [J].
Andreoni, A. A. ;
Rytz, U. ;
Vannini, R. ;
Voss, K. .
VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2010, 23 (01) :1-6
[2]  
[Anonymous], 2003, 2003 ANN BOOK ASTM S
[3]   An in vitro comparison of a 2.7/3.5 mm hybrid plate alone and combined with crossed K-wires for canine pancarpal arthrodesis [J].
Arnott, J. L. ;
Bailey, R. ;
Shields, A. ;
Bennett, D. .
VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2008, 21 (04) :307-311
[4]   A QUANTITATIVE ASSESSMENT OF COMPRESSION PLATE FIXATION INVIVO - AN EXPERIMENTAL-STUDY USING THE SHEEP RADIUS [J].
BAGGOTT, DG ;
GOODSHIP, AE ;
LANYON, LE .
JOURNAL OF BIOMECHANICS, 1981, 14 (10) :701-711
[5]  
BRINKER WO, 1997, HDB SMALL ANIMAL ORT
[6]  
Callister WD, 1999, MECH PROPERTIES META, P112
[7]  
CHAMBERS JN, 1982, J AM ANIM HOSP ASSOC, V18, P875
[8]   Clinical Evaluation of Pancarpal Arthrodesis Using a CastLess Plate in 11 Dogs [J].
Clarke, Stephen P. ;
Ferguson, John F. ;
Miller, Andrew .
VETERINARY SURGERY, 2009, 38 (07) :852-860
[9]  
Cordey J, 2000, INJURY, V31, P1
[10]   PARTIAL CARPAL AND PANCARPAL ARTHRODESIS IN THE DOG - A REVIEW OF 50 CASES [J].
DENNY, HR ;
BARR, ARS .
JOURNAL OF SMALL ANIMAL PRACTICE, 1991, 32 (07) :329-334