Factors influencing taper failure of modular revision hip stems

被引:21
|
作者
Krull, A. [1 ]
Morlock, M. M. [1 ]
Bishop, N. E. [2 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, Denickestr 15, D-21073 Hamburg, Germany
[2] HAW Hamburg Univ Appl Sci, Dept Biomed Engn, Fak Life Sci, Ulmenliet 20, D-21033 Hamburg, Germany
关键词
Hip revision; Taper junction; Fracture; Corrosion; Fatigue; Strength; Titanium; Finite element model; Surface damage; HEAD-NECK TAPER; FRETTING CORROSION; CONTACT FORCES; FEMORAL STEMS; ARTHROPLASTY; FRACTURE; REPLACEMENT; PROSTHESIS; JUNCTION; JOINT;
D O I
10.1016/j.medengphy.2018.02.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stem modularity of revision hip implant systems offers the advantage of the restoration of individual patient geometry but introduces additional interfaces, which are subjected to repetitive bending loading and have a propensity for fretting corrosion. The male stem taper is the weakest part of the modular junction due to its reduced cross section compared to the outside diameter of the stem. Taper fractures can be the consequence of overloading in combination with corrosion. The purpose of this study was to assess the influence of implant design factors, patient factors, and surgical factors on the risk of taper failure of the modular junction of revision stems. An analytical bending model was used to estimate the strength of the taper connection for pristine, fatigued and corroded conditions. Additionally, a finite element contact model of the taper connection was developed to assess the relative motion and potential for surface damage at the taper interface under physiological loading for varyied assembly and design parameters. Increasing the male taper diameter was shown to be the most effective means for increasing taper strength but would require a concurrent increase in the outer implant diameter to limit a greater risk of total surface damage for a thinner female taper wall. Increasing the assembly force decreases the total surface damage but not local magnitudes, which are probably responsible for crack initiation. It is suggested that in unfavourable loading conditions a monobloc implant system will reduce the risk of failure. (C) 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [31] Development of hip joint prostheses with modular stems
    Bae, Ji-Yong
    Farooque, Umar
    Lee, Kyung-won
    Kim, Gyu-Ha
    Jeon, Insu
    Yoon, Taek-Rim
    COMPUTER-AIDED DESIGN, 2011, 43 (09) : 1173 - 1180
  • [32] Usefulness of modular neck adapter in partial hip revision
    Pautasso, Andrea
    Bardellini, Giuseppe
    Stissi, Placido
    D'Angelo, Fabio
    ANNALS OF JOINT, 2023, 8
  • [33] A Role for Modern Primary Cementless Femoral Stems in Revision Hip Arthroplasty
    Skibicki, Hope E.
    Post, Zachary D.
    Kay, Andrew B.
    Czymek, Miranda M.
    Ong, Alvin C.
    Orozco, Fabio R.
    Ponzio, Danielle Y.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (09): : 3269 - 3274
  • [34] Evaluation and Treatment of Painful Total Hip Arthroplasties With Modular Metal Taper Junctions
    Meneghini, R. Michael
    Hallab, Nadim J.
    Jacobs, Joshua J.
    ORTHOPEDICS, 2012, 35 (05) : 386 - 391
  • [35] Strength of the taper junction of modular revision hip stems: The influence of contamination of the taper junction and the joining condition on the relative motion and pull-off force between the stem and neck part of the MRP prosthesis
    Boettcher J.M.
    Sellenschloh K.
    Strube A.
    Huber G.
    Morlock M.M.
    Die Orthopädie, 2024, 53 (1) : 47 - 55
  • [36] Revision Total Hip Arthroplasty With a Modular Cementless Femoral Stem
    Pelt, Christoper E.
    Madsen, Wes
    Erickson, Jill A.
    Gililland, Jeremy M.
    Anderson, Mike B.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1803 - 1807
  • [37] Clinical, functional and radiographic outcomes after revision total hip arthroplasty with tapered fluted modular or non-modular stems: a systematic review
    Koutalos, Antonios A.
    Varitimidis, Sokratis
    Malizos, Konstantinos N.
    Karachalios, Theofilos
    HIP INTERNATIONAL, 2022, 32 (04) : 475 - 487
  • [38] Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems
    Jauch, S. Y.
    Coles, L. G.
    Ng, L. V.
    Miles, A. W.
    Gill, H. S.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1140 - 1146
  • [39] FEMORAL REVISION WITH UNCEMENTED TAPERED STEMS: FROM MONOBLOCK TO MODULAR
    Regis, D.
    Sandri, A.
    Bonetti, I.
    Bartolozzi, P.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2009, 60 (06): : 481 - 486
  • [40] The long-term success of modular proximal fixation stems in revision total hip arthroplasty
    Cameron, HU
    JOURNAL OF ARTHROPLASTY, 2002, 17 (04): : 138 - 141